• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
50A-3PH 3 Phase Current Injection System
50A-3PH 3 Phase Current Injection System

... The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 50A. Voltages up to 18V are available on the main outputs. Three true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. ...
8.7 Separation of grounding conductors
8.7 Separation of grounding conductors

... The purpose of this safety standard is the practical safeguarding of persons during the installation, operation, or maintenance of electric supply and communication lines and associated equipment. This standard contains the basic provisions that are considered necessary for the safety of employees a ...
TEJ2 Wiring Switching-mode Power Supplies Lesson Plan
TEJ2 Wiring Switching-mode Power Supplies Lesson Plan

... THIS COVER”. Instruct students that a power supply must be fully covered to protect from severe shock. Discuss the issue of capacitors potentially storing charges for long periods of time well after being unplugged. 14. Discuss with students the hazards of open terminal strips. This can also be haza ...
Lightning protection systems for gas pressure control and
Lightning protection systems for gas pressure control and

... The main functions of gas pressure control and measurement systems are to monitor and calculate gas volumes, automatically operate the stations by means of volume and conditionoriented connection and disconnection of measurement and control systems as well as volume control and monitoring of the ga ...
Implementation of Thyristor Switched Capacitors for Power Factor
Implementation of Thyristor Switched Capacitors for Power Factor

... inductive in nature and hence draw lagging wattles current, whichunnecessarily load the system, performing no work. Since the capacitive currents is leading in nature, loading the system with capacitors wipes out them. The lower the power factor, the worse the situation becomes from the supply autho ...
amp clamp - Advanced Media Technologies
amp clamp - Advanced Media Technologies

... Alpha’s Amp Clamp eliminates surge voltages in coaxial cable systems caused by lightning strikes, sheath currents and utility-induced switching transients. The proprietary Alpha design also resists false triggering, which is common among triac circuits. The plug-in Amp Clamp circuitry can be factory ...
Push-Pull DC-DC Converter with Planar Transformer for PV
Push-Pull DC-DC Converter with Planar Transformer for PV

... The planar transformer can be built as standalone components, with a stacked layer design or a multiplayer PCB. The main advantages of planar transformer are: very low profile, excellent thermal characteristics, modularity and manufacturing simplicity and the use of higher switching frequency can re ...
6-pin dip zero-cross optoisolators triac driver output
6-pin dip zero-cross optoisolators triac driver output

... 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body,or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in labeling, can be reasonably expected to result ...
A Compact Nested High Voltage Generator
A Compact Nested High Voltage Generator

... Repetition rates will vary for this machine from 1 pps to 1 kHz depending on the applied pulse format. We will report on performance and prospects for higher power operation. ...
1.5SMC6.8AT3 - uri=media.digikey
1.5SMC6.8AT3 - uri=media.digikey

pptx
pptx

... specification revision history. • Some technical changes may require separately written BIRDs, particularly if the parser is affected. – The editorial BIRD will incorporate these changes already. ...
IF 1720 Revision 2
IF 1720 Revision 2

... of damage or debris. Put back cover in place on driver housing and start all (8) back cover screws hand-tight. Initially torque back cover screws to 40 In-lbs in sequence of A-B-C-D-E-F-G-H as shown in Figure 5. Next torque back cover screws up to 79 In-lbs again in the sequence of A-B-C-D-E-F-G-H. ...
FAN1539B / FAN1540B — 1A/1.3A, LDO with Low Quiescent Current
FAN1539B / FAN1540B — 1A/1.3A, LDO with Low Quiescent Current

Voltage Tolerance Boundary
Voltage Tolerance Boundary

Inductance - General Cable
Inductance - General Cable

... Inductance Inductance (L): The property of a circuit or circuit element that opposes a change in current flow. Inductance thus causes current changes to lag behind voltage changes. Inductance is measured in henries (H). Inductance per core of a 3 core cable or of three single core cables comprises t ...
Why specify a Short Circuit and Coordination Study?
Why specify a Short Circuit and Coordination Study?

... addresses the importance of this type of study in articles 110-9, 110-10, 240, and 517.17. It is clear that a thirdparty, independent study performed during/after the equipment submittal process, can prove to be invaluable. A Short Circuit and Coordination Study serves to incorporate all the system ...
600 Watt SUR40 Transient Voltage Suppressor, 100 V, Unidirectional
600 Watt SUR40 Transient Voltage Suppressor, 100 V, Unidirectional

... protected. In this situation, there is a time delay associated with the capacitance of the device and an overshoot condition associated with the inductance of the device and the inductance of the connection method. The capacitance effect is of minor importance in the parallel protection scheme becau ...
SERIES RL CIRCUITS
SERIES RL CIRCUITS

... Since Vp = 2Veff and Ip = 2Ieff we can derive Pavg  ...
Discrimination of residual-current protective
Discrimination of residual-current protective

... current, the settings on the protective devices may be adjusted to achieve discrimination. Use of timedelayed trip units makes this easier. If the discrimination limit is in the table zone, the rating of the upstream protective device must be increased. In this case, Ecodial retains the circuit desi ...
Inductance – Ch 4
Inductance – Ch 4

... increases (and vice versa!). ...
Differential Amplifier
Differential Amplifier

... • A differentiator circuit produces an output that is proportional to the derivative or rate of change of the input voltage over time. • Differentiator circuit can be constructed as shown using an operational amplifier, a resistor, and a capacitor. • Unlike an ideal integrator circuit where the sli ...
The IT (unearthed) power supply system
The IT (unearthed) power supply system

... Naturally there are certain physical limits in this system. The smaller the test current, or rather the higher the insulation resistance, the more difficult it is to register the test current through the measuring transformers. However modern electronics switching techniques allow insulation fault l ...
attachment=2411
attachment=2411

Mar 2002 Unique Instrumentation Amplifier Precisely Senses Differential Voltages from mV to V
Mar 2002 Unique Instrumentation Amplifier Precisely Senses Differential Voltages from mV to V

... is gain-independent. This allows precision extraction of wide range of differential DC signals, from microvolts to volts, with common mode voltages anywhere between the supply rails. The LTC2053 uses sophisticated charge balanced techniques to convert a differential input voltage into a single ended ...
8 Zone Conventional Fire Alarm Control Panel
8 Zone Conventional Fire Alarm Control Panel

... When the fire panel enters a fault condition it will turn on the General Fault indicator and the appropriate fault indicator (refer to 8 for more details). The panel buzzer will sound a slow pulsing tone. System Fault – Severe failure of the panel, the service company must be contacted immediately. ...
< 1 ... 377 378 379 380 381 382 383 384 385 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.