• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ESD protection, TVS devices, and EMI filtering
ESD protection, TVS devices, and EMI filtering

... ElectroStatic Discharge (ESD) is the transfer of an electric charge between bodies of different electrostatic potential, as when a person gets very close to or touches a device or connecting cable. The electric pulses are very short, with voltage values up to several kilovolts. The discharge can do ...
Short-circuit current ratings 3MB
Short-circuit current ratings 3MB

... • Circuit Breakers - must be Listed and marked “currentlimiting” and use published peak let-thru curves • Can only raise downstream branch circuit component SCCR (not fuse IR, not CB IR, not fuse/CB series rating, not CB/CB series rating, not combination motor controller SCCR) • New - can be provide ...
Phasemaster 6 / 7 / 7S
Phasemaster 6 / 7 / 7S

... 28 amps at 50%, 70 amps at 8%, 200 amps @1% duty cycle Operator can save (write) 8 different weld schedules. Operator can save (write) 128 different weld schedules. Schedule protection Schedule protection feature protects schedules 1 feature protects schedules 1 through 127 from unauthorized or inad ...
Surge protection - Phoenix Contact
Surge protection - Phoenix Contact

September 14,201 0 NRC 201 0-0093 10 CFR 50.90
September 14,201 0 NRC 201 0-0093 10 CFR 50.90

Frequently Asked Questions Solid-State Relays Frequently Asked
Frequently Asked Questions Solid-State Relays Frequently Asked

... Vishay Semiconductors ...
65-0084 7800 Series Q7800A,B 22
65-0084 7800 Series Q7800A,B 22

Sectionalization - IEEE Rural Electric Power Conference
Sectionalization - IEEE Rural Electric Power Conference

... • B – Substation Breaker does not trip, coordinated with line Recloser R. • R – Initial trip on fault, 1st trip (fast curve – fuse saving scheme), 1st reclose interval (2 sec) begins. • R - 1st reclose: trips on fault, 2nd trip (slow curve), 2nd reclose interval (5 sec) begins, (fault is on the main ...
16 Transformer and Transformer-feeder Protection
16 Transformer and Transformer-feeder Protection

... e. system fault level The very high flux densities quoted above are so far beyond the normal working range that the incremental relative permeability of the core approximates to unity and the inductance of the winding falls to a value near that of the 'air-cored' inductance. The current wave, starti ...
Paper - WSU Conference Management
Paper - WSU Conference Management

...  The interrupting rating can be as low as 1,200 amps (for some older models) and only go up to 10,000 amps at 115 kV. By contrast a modern circuit switcher can have an interrupting rating of 25,000 amps and a breaker can have even higher (we typically use 40,000 amps interrupting).  The fuses we g ...
Capacitor unbalance protection for blocks in double
Capacitor unbalance protection for blocks in double

... Capacitor unbalance protection function for blocks in double star connection This version of the capacitor unbalance protection can be applied if the capacitors are arranged in two parallel stars (ungrounded) with a current transformer between the neutrals. The stars do not have to be equal in size. ...
Mark VIe Control General
Mark VIe Control General

... terminal block to the I/O pack. Terminal blocks can be removed from the I/O module with field wiring attached in the unlikely event of a failure of the passive circuits on the module. contain two 24 point, barrier type, pluggable, terminal blocks. Each point can accept two 2.05 mm² (0.081 in²) #12 A ...
Protective Relaying Philosophy and Design Guidelines
Protective Relaying Philosophy and Design Guidelines

CIRCUIT PROTECTION
CIRCUIT PROTECTION

south east central railway
south east central railway

... Q25:: What do you mean by Indication Locking and Track Locking and on which levers these are being used? Q26: Explain the working of Snubbing Circuit in Point machine operation using 3wire control. Q27: What is the concept of Cross protection in signalling circuits? Please explain. Q28: Explain the ...
Fault Analysis In Transmission System Using Matlab
Fault Analysis In Transmission System Using Matlab

... a positive-sequence component, in which the phases are in the same order as the original system, i.e., a-b-c a negative-sequence component, in which the phases are in the opposite order as the original system, i.e., a-c-b a zero-sequence component, which is not truly a three phase system, but instea ...
SIPROTEC 4 7SJ63 Multifunction Protection Relay
SIPROTEC 4 7SJ63 Multifunction Protection Relay

... calculated using a thermal homogeneousbody model (according to IEC 60255-8), which takes account both of the energy entering the equipment and the energy losses. The calculated temperature is constantly adjusted accordingly. Thus, account is taken of the previous load and the load fluctuations. For ...
Application Note
Application Note

PHASE-COMPARISON CARRIER-PILOT RELAYS
PHASE-COMPARISON CARRIER-PILOT RELAYS

Interconnect Protection of IPP Generators Using Digital Technology
Interconnect Protection of IPP Generators Using Digital Technology

ISL69147 Data Short
ISL69147 Data Short

... in the quality certifications found at www.intersil.com/en/support/qualandreliability.html Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is ...
Workshop 88`s
Workshop 88`s

... related to current. Varying voltage to an LED+resistor doesn’t work well at low levels. ...
Fault current reduction by SFCL in a distribution system with PV
Fault current reduction by SFCL in a distribution system with PV

... In the present scenario, power quality and power supply are the main problems in power system. The distributed generation (DG) system has got lot of importance because of the limitation of conventional power generation [1]-[3]. The main advantage of DG system is it reduces transmission cost. It has ...
IEEE-NFPA Small Wire Report
IEEE-NFPA Small Wire Report

Distance Protection 7SA6
Distance Protection 7SA6

< 1 ... 16 17 18 19 20 21 22 23 24 ... 68 >

Protective relay



In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected. The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency. Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays. In many cases a single microprocessor relay provides functions that would take two or more electromechanical devices. By combining several functions in one case, numerical relays also save capital cost and maintenance cost over electromechanical relays. However, due to their very long life span, tens of thousands of these ""silent sentinels"" are still protecting transmission lines and electrical apparatus all over the world. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices, or one or two microprocessor relays.The theory and application of these protective devices is an important part of the education of an electrical engineer who specializes in power systems. The need to act quickly to protect circuits and equipment as well as the general public often requires protective relays to respond and trip a breaker within a few thousandths of a second. In these cases it is critical that the protective relays are properly maintained and regularly tested.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report