• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
- IEEE Mentor
- IEEE Mentor

CFE Generator Protection Guidelines for Setting 40 and 64G
CFE Generator Protection Guidelines for Setting 40 and 64G

... ground fault currents are common. Additionally, even if protective relays trip fast, fault currents are present for several seconds, causing major machine damage. This connection is usually limited to low-capacity generator applications and is not covered by the CFE guide. 3) Low-Impedance Grounding ...
3. APPLICATION OF NON-PROTECTION FUNCTIONS
3. APPLICATION OF NON-PROTECTION FUNCTIONS

Fault Finding in Thyristor Equipment
Fault Finding in Thyristor Equipment

... conditions which may be difficult to reproduce. This chapter should help in the location of most faults and does explain the methods which can produce the quickest results. However, there will always be faults which are very difficult to find and no amount of written information will overcome this. ...
The Basic Principles of Electrical Overstress (EOS)
The Basic Principles of Electrical Overstress (EOS)

... (700 mA) would still protect the device, since the maximum continuous operating current for this particular LED is 1000 mA. Even if the LED were to be operated at its maximum rated current of 1000 mA, it would still be protected if the response time of the driver were less than that of the maximum d ...
Micrologic P fonctionnement
Micrologic P fonctionnement

... Improvement of discrimination with HV fuses Better protection of switchgears Understanding Micrologic P- 14/03- DBTP218EN ...
Disconnecting Means
Disconnecting Means

... an elevator code requirement that affects the electrical installation. The electrical installation allows this requirement to be implemented at the disconnecting means for the elevator in NEC® 620.51(B). This requirement is most commonly accomplished through the use of a shunt trip disconnect and it ...
USB 2.0 and USB 3.0 Circuit Protection
USB 2.0 and USB 3.0 Circuit Protection

DDA-3000 - Biddle Megger
DDA-3000 - Biddle Megger

... 4. TIMER STOP MODE - Three modes of operation are available to control the output and timer operation. C.A. (Current Actuate) - When the device to be tested has no contacts other than those involved in the passing of test current, this type of operation is used. In this position, the timer will run ...
orta geri̇li̇m şalt tesi̇si̇
orta geri̇li̇m şalt tesi̇si̇

... Cable output holes for external connection are equipped with cable connection. In low voltage compartment there shall be a cable channel containing auxiliary cable connections between switchgears. Cable connection between switchgears shall be implemented by sockets. 4.2.4.1 Protection Relays Each ci ...
AN347
AN347

... output TMDS line from the HDMI connector while the HDMI source is powered off. As a result, any ESD protection device added to TMDS line has to be powered even if PI3HDMI201/301 is not powered up. In other words, a standby 3.3V should be used employed to Vcc_standby pin shown in figure 3 above. Besi ...
High Impedance Fault Detection on Distribution Systems
High Impedance Fault Detection on Distribution Systems

... The most critical decision to be made after installation of high impedance fault detection is what control actions to take if a HIF is detected. There is no one method for determining which control action a utility should take. Each utility will have to determine a control strategy to fit their goal ...
Volume 7, Issue 2, March-April, 2016, pp.50–58, Article ID: IJEET_07_02_006 http://
Volume 7, Issue 2, March-April, 2016, pp.50–58, Article ID: IJEET_07_02_006 http://

Slide 1
Slide 1

personal protective equipment
personal protective equipment

csl series - Marley Engineered Products
csl series - Marley Engineered Products

... ENCLOSURE - Shall be fabricated of 16 gauge cold-rolled steel (14 gauge optional), with a built-in wireway with factory installed wiring rated up to 45 amps. This makes it unnecessary to fish wires through when wiring two or more heaters in parallel. Removal of the front panel will provide unobstruc ...
Monitoring Devices SENTRON Answers for infrastructure and cities. Configu-
Monitoring Devices SENTRON Answers for infrastructure and cities. Configu-

... Plant safety and operating safety are becoming increasingly important alongside the protection of personnel. Shutdowns due to the unexpected tripping of protective devices cause high costs. It is possible to detect residual currents in the electrical installation before the protective device respond ...
Generator Protection
Generator Protection

... called Main-I and Main-II with at least one of them being carrier aided non-switched three zone distance protection. • The other protection may be a phase segregated current differential (this may require digital communication) phase comparison, directional comparison type or a carrier aided non-swi ...
View Attachment - Northeast Power Coordinating Council
View Attachment - Northeast Power Coordinating Council

View Attachment - Northeast Power Coordinating Council, Inc.
View Attachment - Northeast Power Coordinating Council, Inc.

... disturbance data is available to facilitate analysis of bulk power system (BPS) disturbances. All references to equipment and facilities herein, unless otherwise noted, will be to BPS elements. ...
ISO Rules Part 500 Facilities Division 502 Technical Requirements
ISO Rules Part 500 Facilities Division 502 Technical Requirements

Datasheet
Datasheet

... When a short circuit occurs in the winding element of a capacitor unit, gas can form, causing the capacitor case to swell and eventually burst if left uncontrolled. A protection relay can be used to detect such faults well in advance. The relay compares the star points of two parallel star connected ...
Applying branch circuit breakers and supplementary protectors in
Applying branch circuit breakers and supplementary protectors in

... This line is rated up to 40A and comes in single, double and triple pole versions with instantaneous trip characteristics C and D. Of course, the line is also in conformity with the IEC standard for molded case circuit breakers, IEC 60947-2, and can therefore be universally applied. The NEC defines ...
Yardmaster™ Magnet Controller 4292
Yardmaster™ Magnet Controller 4292

Short-circuit current rating (SCCR) of industrial control panels
Short-circuit current rating (SCCR) of industrial control panels

... • In the power circuit, such as motor controllers, overload relays, fused disconnect switches, and circuit breakers • In the control circuit, such as pushbuttons, signal lamps, selector switches, time-delay switches/relays, switches, control relays • In a combination of two circuits These components ...
< 1 ... 12 13 14 15 16 17 18 19 20 ... 68 >

Protective relay



In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected. The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency. Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays. In many cases a single microprocessor relay provides functions that would take two or more electromechanical devices. By combining several functions in one case, numerical relays also save capital cost and maintenance cost over electromechanical relays. However, due to their very long life span, tens of thousands of these ""silent sentinels"" are still protecting transmission lines and electrical apparatus all over the world. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices, or one or two microprocessor relays.The theory and application of these protective devices is an important part of the education of an electrical engineer who specializes in power systems. The need to act quickly to protect circuits and equipment as well as the general public often requires protective relays to respond and trip a breaker within a few thousandths of a second. In these cases it is critical that the protective relays are properly maintained and regularly tested.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report