• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
SCHUKO socket outlet with RCD protection switch
SCHUKO socket outlet with RCD protection switch

... The SCHUKO socket outlet with FI-circuit breaker is a stationary protection device in socket outlet design for protection level increase according to DIN VDE 0664. The functional principle is voltage independent and corresponds to that of an residual current circuit-breaker (ground fault circuit-bre ...
IOSR Journal of Electrical and Electronics Engineering PP 01-08 www.iosrjournals.org
IOSR Journal of Electrical and Electronics Engineering PP 01-08 www.iosrjournals.org

stepper motor - IndiaStudyChannel.com
stepper motor - IndiaStudyChannel.com

lecture1425873259
lecture1425873259

SELCO D1000 Arc Protection Installation and Configuration Guidelines
SELCO D1000 Arc Protection Installation and Configuration Guidelines

Low voltage high resistance grounding systems
Low voltage high resistance grounding systems

... To add high resistance grounding to an ungrounded deltaconnected system, a neutral point must be created. Three single-phase transformers can be interconnected in a zig-zag or wye-broken delta configuration to provide such a neutral point. The transformers and grounding resistors are chosen to limit ...
ANN BASED DETECTION OF OS CONDITIONS IN POWER SYSTEM
ANN BASED DETECTION OF OS CONDITIONS IN POWER SYSTEM

... completed with the real world signals from digital recorders installed in substations. The latter may also be used for further testing of designed units. Having gathered the comprehensive base of simulation cases one has to elaborate the available data to extract needed information. It is good pract ...
Electrical Alarm Contact for Thermometers and
Electrical Alarm Contact for Thermometers and

Understanding networks
Understanding networks

... A (blue) additional network connects all the protection relays to allow exchanges and decisions as to « which relay is concerned ». ...
H938 - Veris Industries
H938 - Veris Industries

... In this model, the setpoint is adjustable through the action of a twenty (20) turn potentiometer (see the CALIBRATION section). The status output is suitable for connection to building controllers or other appropriate data acquisition equipment operating at up to 30 volts. The H938 relay requires a ...
Relaying Current Transformer Application
Relaying Current Transformer Application

Lecture 19
Lecture 19

... Since this is now a linear network, the faulted voltages and currents are just the sum of the pre-fault conditions [the (1) component] and the conditions with just a single voltage source at the fault location [the (2) component] Pre-fault (1) component equal to the pre-fault ...
APPLICATION NOTE Integrated Overcurrent / Overvoltage Protection Device Helps Protect Telecommunications Equipment
APPLICATION NOTE Integrated Overcurrent / Overvoltage Protection Device Helps Protect Telecommunications Equipment

BusWorks® XT Series Accessory Model XTA-MRNO-6 Interposing Relay Board
BusWorks® XT Series Accessory Model XTA-MRNO-6 Interposing Relay Board

... Power is normally connected to the TB3 power terminals of the module as shown on the previous page. However, this module is equipped to be optionally powered via its DIN rail bus connector provided (Acromag 1005-063), when mated to an optional plug-in terminal block (Acromag 1005-220 or 1005-221). P ...
DC input limit alarm
DC input limit alarm

... been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA's control. Components which wear are not warranted, including but not limit ...
Guidance on RCD`s
Guidance on RCD`s

... Portable RCDs incorporate a plug-pin portion and may have either a socket-outlet portion or may include terminals for external flexible cords, where appropriate. It should be noted that such RCDs do not form part of the fixed electrical installation. Such RCDs have a rated voltage not exceeding 250 ...
Applications of Op-Amps
Applications of Op-Amps

AN9842: Implementing Tip and Ring Protection Circuitry For
AN9842: Implementing Tip and Ring Protection Circuitry For

... protection resistance. As shown in Figure 2, RP has been divided into 3 separate resistors and equals 35Ω. The total resistance of the PTC and RPT on RPR should equal 15Ω. The PTC represents 5Ω of RP (total) and limits the fault current to the TVS/diode bridge and the HC5518X. Additionally 10Ω,1W re ...
NETWORK POWER MONITOR R8 / NPM-R8
NETWORK POWER MONITOR R8 / NPM-R8

... Alarm input – potential free contact only. ...
Loss of AC Voltage Considerations - pes-psrc
Loss of AC Voltage Considerations - pes-psrc

... directional sensing. For the 30° unit, maximum operating torque occurs when the current (op) flow from polarity to non-polarity of the current coil leads the voltage (VPOL) drop from polarity to non-polarity of the voltage coil by 30°. The 60 and 0 units are defined similarly. For all units, the ...
Voltage monitoring relays CM-EFS.2 For single-phase AC/DC voltages
Voltage monitoring relays CM-EFS.2 For single-phase AC/DC voltages

microcontroller based power transformer protection
microcontroller based power transformer protection



... Line numbers are provided along the bottom edge of the drawing. These permit service personnel in the field and at the Milnor® factory to quickly relate circuit locations when discussing troubleshooting over the phone. Page and line numbers are referenced on the drawing as explained in items five an ...
Charging Around the Circuit
Charging Around the Circuit

Short Circuit Current Calculations
Short Circuit Current Calculations

... When there are motors in the system, motor short circuit contribution is also a very important factor that must be included in any short-circuit current analysis. When a short circuit occurs, motor contribution adds to the magnitude of the short-circuit current; running motors contribute 4 to 6 time ...
< 1 ... 19 20 21 22 23 24 25 26 27 ... 68 >

Protective relay



In electrical engineering, a protective relay is a device designed to trip a circuit breaker when a fault is detected. The first protective relays were electromagnetic devices, relying on coils operating on moving parts to provide detection of abnormal operating conditions such as over-current, over-voltage, reverse power flow, over- and under- frequency. Microprocessor-based digital protection relays now emulate the original devices, as well as providing types of protection and supervision impractical with electromechanical relays. In many cases a single microprocessor relay provides functions that would take two or more electromechanical devices. By combining several functions in one case, numerical relays also save capital cost and maintenance cost over electromechanical relays. However, due to their very long life span, tens of thousands of these ""silent sentinels"" are still protecting transmission lines and electrical apparatus all over the world. An important transmission line or generator unit will have cubicles dedicated to protection, with many individual electromechanical devices, or one or two microprocessor relays.The theory and application of these protective devices is an important part of the education of an electrical engineer who specializes in power systems. The need to act quickly to protect circuits and equipment as well as the general public often requires protective relays to respond and trip a breaker within a few thousandths of a second. In these cases it is critical that the protective relays are properly maintained and regularly tested.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report