Download CA‐NLH‐012  Holyrood Blackstart Diesel Units Application  Page 1 of 1 Q. 

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electrical substation wikipedia , lookup

Brushless DC electric motor wikipedia , lookup

Opto-isolator wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electric motor wikipedia , lookup

History of electric power transmission wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Ohm's law wikipedia , lookup

Buck converter wikipedia , lookup

Distribution management system wikipedia , lookup

AC motor wikipedia , lookup

Surge protector wikipedia , lookup

Induction motor wikipedia , lookup

Stray voltage wikipedia , lookup

Rectiverter wikipedia , lookup

Alternating current wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Mains electricity wikipedia , lookup

Voltage optimisation wikipedia , lookup

Stepper motor wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
CA‐NLH‐012 Holyrood Blackstart Diesel Units Application Page 1 of 1 1 Q. (Re: November 2013 Report to Board on Holyrood Black Start Analysis, page 7) 2 Hydro states “there is expected to be some discrepancy between predicted 3 electrical behaviour and the real world system behaviour”. Has Hydro been able to 4 calibrate modeling results to the real world in an effort to provide greater comfort 5 that the diesel plant solution will indeed work in the real world system? 6 7 8 A. 9 10 Hydro has had success comparing the modeled motor inrush current with measured values. Hydro's application stated: 11 The station service voltage must be maintained during motor start, as a 12 severe voltage drop may cause other thermal plant equipment to cease 13 operation during a critical motor starting event. The voltage must not drop 14 below 81 percent during a motor start. However, given the fact that there is 15 expected to be some discrepancy between the model predictions and the real 16 world observations, any solution which only marginally meets this 17 requirement must be studied in greater detail before final acceptance of the 18 solution. 19 20 The diesel plant solution does not show marginal results. Therefore, the analysis of 21 the diesel units can be confidently relied upon to demonstrate that such units will 22 be able to start the boiler feed pump motors.