* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
Download Commun-ications Test Facility
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Mains electricity wikipedia , lookup
DRDO 1. IRDE (INSTRUMENTS RESEARCH DEVELOPMENT ESTT.), DEHRADUN TEST FACILITIES / EQUIPMENT AVAILABLE AT IRDE, DEHRA DUN Ser Test Facilities/ No. Parameter Test Equipment/ Machine Range/ Accuracy Availability at Station Remarks 1. Stabilisation Accuracy Measurement Test Facility 3 Axis motion Simulator with Line of Sight Measurement Instrumentation upto 400 /s Measurement accuracy upto 5 sec of an arc Yes -- 2. Inspection of Aspheric/ Spherical/Lenses, Flat mirrors and measurement of roughness as per optical parameters Form Taly Surf 0.01 Resolution Yes -- Inspection/measurement of optical parameters such as EFL, BFL, Resolution & Concentricity Askania Optical Collimator 0.001mm Yes -- 3. 2 4. a) MTF/OTF, EFL, Transmission b) MRTD, MDTD Thermal Imaging performance Test set up IRMTF Yes -- MRID 8-11m Spectral Bond 5.75 cycles/mrad Yes -- 5. Testing of Image Intensifier Tubes for Resolutions, EBI, Magnifications, distortions, Lumineous Gain, Radiant Gain, Signal to Noise ratio, Screen Brightness, Photocathode spectral Response, Veiling Glare etc. Test setup for various parameters within +/-2% photometric accuracy Yes An extensive test lab has been created at IRDE for testing II Tubes of various types. 6. Apparatus for Measurement of % Transmission/(Integrated & Spectral) & Reflectivity Test setup +/- 2% Yes -- 7. Apparatus for Measurement of Veiling Glare index. --do-- +/-2% Yes -- 8. Performance Evaluation Test facility for Image Intensifier Based Night Vision Devices to measure technical parameters viz. Mag., FOV, Definition and system resolutions etc. Illuminators with 80 metres long suitable combination dark hall of filters and lamps to simulate varied night light conditions(10-1 to 10-4 lux) ranging from full moon to overcast conditions encountered during night. High, medium and low contrast USAF resolution pattern to check performance under different contrast conditions. Yes This facility is unique of its kind and is being extensively used for testing of NVDs by various PAs. 3 9. Adherence of thin film coating 10. Reflection & Transmission measurement from 1-27 m Adherence Tester +1 psi Yes -- FTIR Spectro photometer +1% Yes -- 11. Measurement of radius of Curvature of Lenses and test plates 12. Measurement of Focal Length/Back focal length and eccentricity of lenses Precision Spherometer 4mm to / .001mm Yes -- Focometer 10mm to Yes 1200mm +ve 10mm to 1050mm -ve/.04mm to .05mm -- 13. Measurement of Refractive index and V value Abbe’s Refractometer 1.3 to 1.7 / .0001 Yes -- 14. Measurement of angles Pyramidal error through angles, Surface flatness 15. Measurement of radius of curvature and surface accuracy of flats, spherical and performance of subassembly Precision Spherometer 360/1sec of an arc Yes -- Phase shifting Laser interferometer Max. aperture Yes /150mm, Radius measurement upto .001mm, surface deformation upto /20,where =632.8nm -- 16. Measurement of dioptric power and axis of cylindrical lenses Dioptrometer 25 Diopter/0 to 180 Yes axis .25 Diopter -- 17. Low/High Temp. Test Low/High Temp. chamber(KashiNath Hyderabad) space(1m x 1m x 1m) -60C to 100C +/-3C Yes Testing spec. JSS-55555 IS-10236 Mil-STD 810E. One port hole dia 70mm 4 18. Low/High Temp. Test Low/High Temp. chamber(Kasco-Pune) space(1m x 1m x 1m) -60C to 100C +/-3C Yes Testing spec. JSS-55555 IS-10236 Mil-STD 810E. One port hole dia 105mm 19. Dry Heat High Temp. Test High Temp. Test chamber(Labman) space(1.2mx1.2mx1.2m) Ambient to 100C +/-2C Yes Testing spec. JSS-55555 IS-10236 Mil-STD 810E. One port hole dia 50mm 20. Damp Heat Test chamber(Vijay Luxmi) Damp Heat Test 10C to 100C +/-2C JSS-55555 W/space(1.2mx1.2mx1.2m) RH 95% +/-5% Yes Testing spec. Damp Heat Test chamber gallon Comp (London) W/space (80cmx70cmx70cm) Yes 21. Damp Heat Test Ambient to 100C +/-2C RH 95% +/-5% IS-10236 Mil-STD 810E. One port hole dia 50mm Testing spec. JSS-55555 IS-10236 Mil-STD 810E. One port hole dia 50mm 5 22. Damp Heat Test chamber W/space Damp Heat Test +/-2C (80cmx60cmx70cm) 10C to 100C JSS-55555 RH 95% +/-5% Yes Testing spec. 23. Storage Test Storage Test chamber (KascoPune) W/space (90cmx90cmx120cm) 15C to 80C +/-2C RH 95% +/-5% Yes Testing spec. JSS-55555 IS-10236 Mil-STD 810E. One port hole dia 100mm 24. Dust Test Dust Test chamber Make deal, Calcutta W/Space(1mx1mx1m) Ambient to 100C +/-3C RH<30% 25gm dust +/-5gm should be collected in 5min. Yes Testing spec. JSS-55555 IS-10236 Mil-STD 810E. One port hole dia 100mm 25. Salt Spray Test Salt spray Test chamber Labman, Calcutta W/Space(110cmx60cm) Ambient to 50C +/-2C High humidity nature of corrosion Saline. Yes Testing spec. JSS-55555 IS-10236 MIL-STD 810E. One port hole dia 100mm IS-10236 Mil-STD 810E. One port hole dia 50mm 6 26. Bump Test Bump Test machine Vijay Luxmi Bangalore w/space (60cm x 60cm) Max. test load Yes 113kg Height of fall adjustable 2.5cm max frequency 2 to 4 Bumps per second Peak acc. 40g +/- 4g Testing spec. JSS-55555 IS-10236 MIL-STD 810E One port hole dia 100mm 27. Drop Test Drop test Machine make(Budh Singh and Sons,Roorkee) w/space(86cmx61cm) Max test load 50 kg Max drop height 150cm Peak acc. 100g +/-4g Testing spec. JSS-55555 IS-10236 MIL-STD 810E Yes One port hole dia 100mm 28. Shock Test Shock Test Machine Avco-USA w/space 40cmx40cm Max load test 90 kg Peak acc. 15g to 1500g 1500g Pulse duration .5mile sec to 18 mile sec. Pulse profile half sine wave & Terminal peak saw tooth. Yes Testing spec. JSS-55555 IS-10236 MIL-STD 810E One port hole dia 100mm 29. Vibration Test system Sinusoidal Random Sine-on-Random Vibration Test system (SDPL Roorkee) Max acc. 65g Bare Yes table load capacity 100kg at 30mmp top. Displacement Frequency 5 to 2000Hz Power output 2000kgf with sliptable mount platform area 30cm dia. Testing spec. JSS-55555 IS-10236 MIL-STD 810E. One port hole dia 100mm 7 30. Combined Vibration test with Low/High Temp. Vibration test system from SDPL,Roorkee and chamber Kasco, Pune. Range and accuracy Yes of vibration machine Please see Sr No.29 Chamber test space (1mx1mx1m) Temp. -40C to 100C +/-2C Testing spec. JSS-55555 IS-10236 MIL-STD 810E One port hole dia 100mm 2. CABS (CENTRE AIR BORNE SYSTEMS), BANGALORE COMPENDIUM OF TEST EQUIPMENT/TESTING FACILITIES Sl Test Facilities/ No. Parameter 1. Lightning Test Facility Test Equipment/ Machine i) Impulse Voltage Generator Range/ Accuracy 4000 kV 3% Energy = 126 kJ Rise Time = 1.2 us ( 10%) Fall Time = 50us ( 10%) Availability at station Remarks CABS, Bangalore Used for testing lightning attachment points ii) Current Generator ‘A’ 200 kA 10% Action Integral = 2 x 106 A2 S 20% Duration = 500 us CABS, Bangalore ii, iii, iv & v used for testing Direct effects of lightning iii) Current 2 kA 10% Generator ‘B’ Max. Charge Transferred = 10 C 10% CABS, Bangalore iv) Current Generator ‘C’ CABS, Bangalore 200 – 800 A 20% Max. Charge Transferred = 200 Used for testing Indirect effects of lightning 9 v) Current Generator ‘D’ vi) Current Generator ‘E’ 2 HVDC Test Facility 1200 kV HVDC Generator C 20% CABS, Bangalore 100 kA 10% Action Integral = 0.25 x 106 A2 S CABS, Bangalore 50 kA 10% Rate of Rise = 30 kA/us 1000 kV 3% 25 mA Ripple = 5% CABS, Bangalore For withstand voltage test of insulating systems 10 Sl Test Facilities/ No. Parameter 3. Global Positioning System (GPS) Test Facility Test Equipment/ Machine STR 4760; L1; C/A Code; 12channel GPS Satellite Signal Simulator with built-in trajectory generators for Space vehicles, aircraft, ships & ground vehicles. Range/ Accuracy Availability at station Remarks No. of Sat. Channels : 12 CABS, Bangalore Used for testing GPS / DGPS equipment. Output Frequency : 1575.42 MHz 158 Hz Signal level : -160 dBW 20 dB Signal Level Resolution : 0.1 dB Can be used for testing as development support. Velocity range : 120.000 m/sec Acceleration Range : 3600 m/sec2 System outputs Jerk Range: 5000 m/sec3 RF signals as per GPS ICD- Pseudorange error : 0.1 m (RMS) 200 B Pseudorange Rate Error : 0.1 m/sec (RMS) Acceleration Error : 0.005 m/sec2 (RMS) Jerk Error : 0.02 m/sec3 (RMS) Can be used for dynamic testing of System level GPS / DGPS equipment performance. 11 4. Commun-ications Test Facility Fast Installation Tester (Marconi 46882-262N) - Forward & Reverse Power - VSWR Accuracy - Voltmeter - Resistance Meter - Identification of Antenna Shorts - Auto Detect of Pulse Transmission 70MHz to 1000MHz (Range) 0.1dB (Accuracy) 0.1 (Accuracy) 30mV (Accuracy) 0.1 (Accuracy) CABS, Bangalore Handheld Oscilloscope (Tektronix THS730A) Radiocommunication Service Monitor (Rohde & Schwarz CMS 54) 0-200MHz (Range) 5mV/Div (Accuracy) --Do-- 0.4 MHz to 1 GHz (Range) 0.4dB (Accuracy) --Do-- 12 5. Microwave Test Facility Vector Network Analyzer HP8720ES (Agilent) Spectrum Analyzer HP8563E (Agilent) Pulsed/CW Microwave Counter HP5361B (Agilent) High Frequency probe HP85024A (Agilent) Microwave Power meter EPM441 (Agilent) Microwave Power Sensor HP8481A (Agilent) Peak Power Meter/ Digital Sampling Analyser 4500 (Boonton) Synthesized Signal Generator HP83731B (Agilent) Hand Held High Performance Power Density meter. Model No 50 (Raham) 50 MHz to 20 GHz Accuracy : Amp : 0.1 dB at –40dB Phase : 1 at –40 dB 30 Hz to 26.5GHz Accuracy : Sweep : 1% Amplitude : 1dB Freq : 1*10-8 * Final Frq 10Hz to 26.5GHz Accuracy : 1 LSD 300 kHz to 3GHz 1dB for 300kHz to 1GHz Accuracy : -2 to 3dB > 1GHz 100 KHz to 110GHz Power range : -70dBm to 44dBm Accuracy : 0.02dB(log) 10MHz to 18GHz Power range: –30 dBm to 20dBm Accuracy : -4% to 2% 10 to 20dBm Negligible: -30 to +10dBm 30 MHz to 40GHz Power Range : -40dB to 20dB(pulse) -50dB to 20dB(CW) Accuracy : 0.065 at 0dBm 1GHz to 20GHz Accuracy : 1 dB CABS, Bangalore 0.2MHz to 26 GHz Freq Sensitivity : 2dB Accuracy : 0.5 dB CABS, Bangalore CABS, Bangalore CABS, Bangalore CABS, Bangalore CABS, Bangalore CABS, Bangalore CABS, Bangalore 13 3. MTRDC, BANGALORE PROFORMA Compendium of Test Equipment/Testing Facilities Sl N o 1. Test Facilities/ Parameters Test Equipment/Machine Range/ Accuracy Availability at Station Precision Machining Facilities 1. Schaublin CNC Lathe 2. Centreless grinding machine 3. Precision honing machine 4. ACCUCUT Precision ceramic grinding and slicing machine 5. Precision Praga milling machine 5 microns 2 microns Available 1 microns 10 to 20 microns 25 microns 2. 3. Precision Measurement facilities 1. XYZ non-contact measuring microscope 2. 3-D Co-ordinate measuring instrument accuracy 10 microns Materials Laboratory 1. Vacuum & electron beam evaporation system for coating of lossy materials, thin films on microwave tube components 2. RF/DC sputtering system - for sputter coating of thin films of materials such as Tantalum, Zirconium, Titanium etc. on microwave tube components. 15" dia chamber ; <5x10-6 torr vacuum Available accuracy 50 microns 3 target sputtering ; target dia 4" Available Remarks 14 4. High temperature sintering and brazing stations 1. CENTORR high vacuum high temperature furnace 2. Vertical retort furnace 3. Horizontal muffle furnace 4. RF brazing station 5. Leak Detector (Hindi make) 6. Leak Detector(Varian) 5. 6. Laser Welding machine Electron Tube testing facilities 1. For precision laser welding of microwave tube sub-assemblies 1. Electron beam analyzer system 2. UHV processing station (For evacuation of microwave tubes) 3. a) Low power magnetreater/ charges model no. 595 b) High power magnetreater / charges model no. 9034 Size: 6"x6"x6" Temperature 25000C, Atmosphere: Vacuum (10-6 Torr), Dry and wet hydrogen Diameter 6 inches, temperature: 11000C, atmosphere: Dry hydrogen Diameter 6 inches, temperature: 11000C, Atmosphere: Dry and wet hydrogen Temperature: 10000C, atmosphere: Dry hydrogen 10-8 Torr 10-9 Torr spot size: 50 microns For testing of electron guns designed and developed, before integration into the microwave tube 10-8 Torr vacuum or better. Baking facility available upto 4000C Available Available Available 12KJ/6KJ 18KJ/12KJ 7. HVPS-1 (High Voltage Power Supply) Beam voltage (cathode) Beam current (cathode) Heater voltage Heater current Anode voltage Anode current 15kV (max) 2A (peak) 15Vdc/ac rms 5A (max) 2kV dc 1mA Available 15 Bias voltage Pulse top voltage 8. HVPS -2 Collector voltage Beam voltage (cathode) Beam current (cathode) Heater voltage Heater current Anode voltage Anode current Bias voltage Pulse top voltage 9. HVPS-3 Collector voltage Beam voltage (cathode) Beam current (cathode) Heater voltage Heater current Anode voltage Anode current Bias voltage Pulse top voltage 10. Microwave testing facility Collector voltage 1. Spectrum analyzer 2. Microwave pulsed freq. counter 3. Microwave freq. counter -50V tp -2950V dc 0 to +2000 V dc -12 kV 32kV (max) 3.5A (peak) 15Vdc/ac rms 5A (max) 2kV dc 1mA -50V tp -2950V dc 0 to +2000 V dc -18 kV Available 50kV (max) 20A (peak) 26Vdc/ac rms 15A (max) 1kV dc 1mA -50V tp -2950V dc 0 to +2000 V dc -45 kV Available 100 Hz-2.5GHz in the low freq. band 2 GHz-22 GHz in the pre selected microwave band Available 100 Hz-26.5 GHz 10 Hz-26.5GHz Synthesized sweeper: 0.0120.3GHz S-parameter test set: 45MHz-26.5GHz +20dBm Max, 40 VDC max 16 4. Vector network analyzer 5. Scalar network analyzer 6. Noise generator 7. Precision LCR meter 8. Peak power analyzer 10 MHz-60GHz Freq. 2 GHz-18 GHz ; O/P power: -20dBm 75 KHz- 30MHz upto 26.5 GHz