Download Test Procedure for the NCP1013ADAP Evaluation Board

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Ohm's law wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power inverter wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Printed circuit board wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

TRIAC wikipedia , lookup

Electrical ballast wikipedia , lookup

Rectifier wikipedia , lookup

Stray voltage wikipedia , lookup

Surge protector wikipedia , lookup

Schmitt trigger wikipedia , lookup

Voltage optimisation wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Ground (electricity) wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Power electronics wikipedia , lookup

Current source wikipedia , lookup

Buck converter wikipedia , lookup

Mains electricity wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Current mirror wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
Test Procedure for the NCP1013ADAP Evaluation Board
Figure 1 Top view of NCP1013 demo board, marked MIC1782
MIC1782 represents an application example for a 6W AC/DC adapter. Nominal voltages (at no load)
are 12V. It is a universal mains AC/DC adapter.
The following steps detail the test procedure for all this board:
1Be careful when manipulating the boards in operation, lethal voltages up to 700V are present on the
primary side. An isolation transformer is also recommended for safer manipulations.
Necessary Equipment:
1 Current limited 230Vrms AC source (current limited to avoid board destruction in case of a
defective part) or a 350VDC source (also current limited ≈ 200mA)
1 DC volt-meter able to measure up to 20V DC. A hand-held device, e.g. a FLUKE
1 DC amp-meter able to measure up to 5A DC. Again, a hand-held device, e.g. a FLUKE
1 25Ω/10W resistor
The board is operated without the J3 jumper / shunt (jumper is removed for the test).
1. Make sure there is an insulated jumper wire along the silkscreen line labeled “strap” located near
the output terminal block. If there is not, one must be added for the board to function properly.
2. Apply 230V AC over the board AC inlet. Output pins Vout (+) and Ground (-) are left floating.
3. Measure the output voltage between pins +Vout et Ground with a volt-meter on the 12V range
(normally 12.2V ± 5%).
4. Connect the 25Ω/10W resistor between pin +Vout et Ground. Verify that the output voltage stays
above 12V. Beware of the resistor that gets hot during the measurement (P = 6W).
5. Now decrease the input voltage down to 90VAC and check that bullet 3 is also ok.
6. Disconnect the resistor. Now connect the amp-meter (5A DC range) between pins +Vout et
Ground. You actually create a short which shall trigger the protection circuitry. As a result, the
output current you read shall be less than 1A DC. The reading is unstable by nature, this is
normal and due to the burst operation.
7. Remove the mains and keep a few seconds bullet 5 (short-circuit ) to discharge the bulk capacitor
If every step is going well, the board is considered to be ok.
9/21/2009
www.BDTIC.com/ON/
-1-
www.onsemi.com