Download ADVANCED FIRING MODULE • Cost Effective Upgrades

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stray voltage wikipedia , lookup

Power over Ethernet wikipedia , lookup

Stepper motor wikipedia , lookup

Power engineering wikipedia , lookup

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Voltage optimisation wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Power MOSFET wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Power electronics wikipedia , lookup

Mains electricity wikipedia , lookup

Alternating current wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Transcript
ADVANCED FIRING MODULE
• Cost Effective Upgrades
Preserve existing capital investment
• Zero Downtime Retrofits
Minimize impact on production
• Open Architecture Communications
Pain-free interfacing to existing controls
• Pre-Engineered Solutions
Keep the muscle,
replace the brains
Many times the lowest
cost strategy to upgrade
a machine is to re-use
expensive components
such as motors, SCR power
converters, and bus bars.
By keeping the expensive
"muscle" components and
replacing only the control
equipment “brains," your
Nidec solution will:
• Achieve new system
performance
• Improve machine uptime
• Reduce upgrade downtime
• Lower capital material costs
Guarantee success
Nidec's AFM
The Advanced Firing Module, or AFM is used to control an external, 3 phase, SCR
(thyristor) power stack of an existing DC drive. The AFM is a fully digital controller
that possesses all the functionality of the proven ADDvantage-32 Plus series of DC
drives including a digital motor field supply.
TM
An AFM can be used to replace virtually any manufacturers' DC drive SCR stack
controller.
The ADDvantage-32 Plus family of DC drive retrofit packages can be interfaced
directly to the SCR gates.
Upgrade your existing DC SCR drives to new drive performance with standard,
pre-engineered solutions for most major manufacturers, including:
• General Electric: Silcomatic I and II, Siltrol, Siltron, DC300, DC2000
• Westinghouse: T100, C56, M4, M4CH, M4CL, M5, M5B
• Reliance: S6R, MaxPac, DCS5000, Automax
• Allen-Bradley: 1395, 1397, Stromberg (ABS)
• Siemens: Simoreg, SYDADYN C/D
• Robicon: all models
ADVANCED FIRING MODULE
CHUNK-A-TIZE
Let our experienced engineers develop a plan to phase in or "CHUNKA-TIZE" your machine modernization section by section. Drives can
be modernized during regularly scheduled outages without additional
downtime.
Utilizing the distributed intelligence of the ADDvantage-32TM platform,
new AFM controllers can be installed one at a time. The interface to
your existing controls is maintained as additional sections are added
until the complete machine has been upgraded.
Zero Downtime Installation Process
The downtime, or lost production time, resulting from a normal drive
system installation often exceeds the cost of a new system.
ADDVANTAGE-32 PLUS
POWER
RUNNING
EMERG STOP OK
DRIVE READY
USER LED
CURRENT LIMIT
FWD BRIDGE ON
REV BRIDGE ON
reset
enter
DRIVE FAULT
FIELD LOSS
IOC FAULT
Nidec's retrofit techniques can eliminate installation downtime.
We plan installations around your operations by coordinating with your
team members to minimize downtime. Upgrades are often completed
section-by-section during normally scheduled machine maintenance
without losing a minute of production time.
Check our web site for more detailed specifications, drawings, and installation
instructions. www.nidec-avtron.com
SPECIFICATIONS
6 pulse single and parallel bridge firing circuits
• AC/DC voltage and current sensing and isolation hardware
• Pulse transformers with and without pulse shaping, up to
10,000 volt isolation
• Gate power supplies from 24 to 200vdc up to 100 amps
Replacement installation cabling and connectors
• 12 Pulse solutions
• Parallel and series configurations
• Distributed firing using a series bridge of gate pulse amplifiers
• Differential current protection
• Bridge balance adjustment
Gate pulse amplifiers
• Low voltage – amplified gate SCRs
• High voltage – non amplified gate applications
Robust communications for system interface, control & diagnostics
RS-485 mutli-drop serial port
Rockwell – DF1 slave
Optional mutli-protocol Ethernet support
Rockwell - Ethernet IP®
GE - Ethernet Global Data®
Schneider - Modbus® TCP
Nidec Avtron Automation Corporation
7555 east pleasant valley road | bldg 100
Independence | Ohio 44131
p: 216.642.1230
www.nidec-avtron.com | www.nidec.com