* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download VertX
Audio power wikipedia , lookup
Power inverter wikipedia , lookup
Power over Ethernet wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrification wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Voltage regulator wikipedia , lookup
Electrical substation wikipedia , lookup
Buck converter wikipedia , lookup
Power MOSFET wikipedia , lookup
Power engineering wikipedia , lookup
Surge protector wikipedia , lookup
Power electronics wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
VERTX AISLE LIGHTER Vertical Aisle Lighter High-Bay Luminaire WAREHOUSE + AISLE ENVIRONMENTS As warehouses grow and aisles become taller and longer, the need has arisen for a luminaire that can deliver the horizontal punch while providing vertical uniformity. Standard aluminum high-bays can offer a very narrow distribution but their symmetric distribution produces a “scallop” effect of uneven vertical illumination. Prismatic acrylic and glass luminaires provide better vertical uniformity but at higher mounting heights it requires more luminaires to meet the horizontal luminance requirements. OPTIMUM PERFORMANCE The VertX aluminum reflector was designed to address the shortcomings of typical high-bay luminaires by offering an asymmetrical distribution for better vertical uniformity but with a strong downward punch to meet the high horizontal lighting requirements. Unlike traditional high-bays that produce a symmetrical distribution, the VertX was designed specifically to fit the long narrow warehouse aisles that are most common today. ENERGY SAVINGS OPPORTUNITIES This distribution allows the luminaires to be spaced further apart and deliver higher horizontal light levels versus traditional products, or use the same number and reduce the lamp wattage of luminaires for higher vertical uniformity and equivalent horizontal illumination. For the ultimate in energy and maintenance savings, combine the VertX with Cooper Lighting’s ECONTM electronic H.I.D. ballast and LumaWatt Hi/Lo control systems. The VertX aisle lighter is the H.I.D. solution to meet today’s challenging warehousing designs. Powered by technology ECONTM is available only in the Benchmark housing. >>> Typical High-bays vs. the VertX HORIZONTAL AVG. FIXTURE TYPE QTY. REQ. MAX. MIN. Aluminum High-Bay 11 Acrylic High-Bay 14 30.25 33.8 30.82 33.6 VertX 10 33.6 Acrylic/Aluminum 18 16 VERTICAL MAX./MIN. AVG. MAX. MIN. MAX./MIN. 15.4 2.19 19.1 1.76 17.5 59.6 2.9 20.55 18.1 56.1 3.4 39.5 16.7 16.5 2.37 15.5 36.8 3.1 11.87 29.97 35.1 12.2 2.88 20.1 55.8 2.3 24.26 30.5 34.6 18.6 1.86 20.8 54.7 3.1 17.65 Aislelighter Modified Aluminum High-Bay Aisleligher AISLE:...........................8'10" x 200' x 32' MOUNTING HEIGHT:.....30' RACKS:.........................25' REFLECTANCE:.............Ceiling: 50%, Aisle: 0%, Wall 10% • HORIZONTAL REQUIREMENTS—Fewer fixtures. • VERTICAL REQUIREMENTS—Same number of fixture with lower wattage. 1 Indoor Lighting Solutions HB VertX Cooper Lighting Specification Features REFLECTOR The VertX is a hydroformed aluminum reflector scientifically designed with multiple facets to produce a long narrow distribution to provide the right balance of horizontal and vertical illumination. Rigid construction and an anodized finish ensure consistent optical performance. The bottom of the VertX reflector is symmetrical to allow easy installation of safety glass lens or wire guard accessories. LAMP The VertX was designed to use clear HID lamps for maximum lumen output and performance. The vertical lamp orientation delivers higher lumen output and longer lamp life. Requires mogul-base 175-450W Metal Halide or 250-400W High Pressure Sodium lamps. EB E&G VertX HOUSING + BALLAST The VertX reflector assembles easily to either the Steeler or Benchmark housings. AV19 reflector mounts easily to the ladder bracket assembly or die-cast neck and distributions can be adjusted for precise control. The ENVA19 is provided with a die-cast aluminum neck and provides for a wide range of distributions from concentrated to wide. Both the Steeler and Benchmark ballast housings are available with magnetic or ECONTM electronic HID ballast. The ECONTM offers Electronic HID ballast superior lamp maintenance and its 0-10V variable dimming capability make it ideal for warehousing applications. MOUNTING Steeler and Benchmark housings ship standard with an easy slide-on die-cast aluminum mounting box with a tapped opening for 3/4" conduit. Hook, cord and plugs, remote connections, Thru-Way power and pendant hooks are available. All products are also available with MWS modular wiring. MWS installs in 1/3 of the time as conduit and MC cable and offers great flexibility to address future building changes. SS VertX L U M AW AT T [ I N D I V I D U A L F I X T U R E C O N T R O L ] LumaWatt motion detector works in conjunction with fixture dimmers to provide bi-level control based on an area’s occupancy. Motion detector is passive infrared type and reacts to changes in infrared energy (heat) within the coverage area. LumaWatt individual fixture controls are the perfect solution for warehouse and storage area retrofit opportunities. Wiring is integrated directly to the housing without the need to run additional control wires throughout the facility. SE E&G VertX Cooper Lighting HSW or LSW Option Indoor Lighting Solutions 2 INDUSTRIAL>>>Aluminum High-Bay SS VertX 150-450W HP/MH/MP/ML V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E 26 7/8" [683mm] A P P L I C AT I O N The SS VertX aisle lighter is ideal for higher mounting height warehouse applications. Its unique distribution pattern delivers high horizontal illumination while reducing “scallops” or hot spots for a more uniform vertical surface. 19" [483mm] LUMARK® MOUNTING O R D E R I N G I N F O R M AT I O N Easy slide-on die-cast aluminum S A M P L E N U M B E R : M H S S - A V 1 9 - M - 4 0 0 - M T- Q mounting box with tapped opening for 3/4" conduit. HOUSING Heavy-duty, formed steel housing LAMP TYPE SERIES REFLECTOR TYPE HP=High SS=Steeler AV=VertX Pressure Sodium 1 MH=Metal Halide 2 MP=Pulse Start MH (CWA) 2, 3 ML=Pulse Start MH (Linear Reactor) 2, 3, 4 REFLECTOR DIAMETER 19=19" with an open air ballast for cooler operation is finished in a white polyester powder paint. BALLAST High power factor ballast with class H insulation. Minimum starting temperature is -40°C (-40° F) for HPS and -30°C (-20° F) for MH, MP and ML. UNIVERSAL BRACKETS Universal ladder brackets allow for the flexibility to change out with other reflectors available in acrylic or glass. SOCKET Mogul-base porcelain socket. REFLECTOR Computer-designed, field-adjustable reflector mounts easily and allows multiple distribution patterns for SOCKET POSITION/ DISTRIBUTION 5 C=Concentrated M=Medium W=Wide LAMP WATTAGE 150=150W 6 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W 450=450W VOLTAGE 7 OPTIONS + 120V ACCESSORIES 11 208V (See Below) 240V 277V 347V 480V MT=Multi-Tap 8 TT=Triple-Tap 9 5T=5-Tap 10 OPTIONS + ACCESSORIES OPTIONS (add as suffix) 11 P=Pre-set Socket Position from the factory SS=Space Saver Feature QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3, MWS, RM or HC) RM=Remote Mount 12 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 13 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 13, 14 HSW=Integral LumaWatt Sensor and Control with Wide Distribution for CWA Magnetic Ballast 13 Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start) EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts) EM/SC=Quartz Restrike wired for Separate Circuit 15 F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240, or 480V only) FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1 or SHK. EXAMPLE: PC3-120V ACCESSORIES (order separately) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1, or SHK PHC-XXXV=Power Cord and Plug 18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage precise control. PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. EXAMPLE: PHC-120V PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). EXAMPLE: PHC-120V-NEMA C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK) MW=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. EXAMPLE: SCF6=6' Cable) SCR=Aircraft Safety Cable for Housing to Reflector L/TCB=Less Top Connector Box (Housing shipped less top connector box. Specify when using TWMBS accessory) LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240 or 480V) TWMBS=Thru-way Mounting Box C3=3' Cord-No Plug-Requires FH-1, FL-1, or SHK MBT=Twin Mount Bracket (Fixtures must be same voltage,wattage and without hooks, loops or plugs) WG19/AV=Wire Guard for AV19 (Not compatible with “SGB19”) SGB19/AV=Safety Glass Bottom for AV19 (Not compatible with “WG19”) WG19/SGB/AV=Wire Guard with Safety Glass Bottom S H I P P I N G D ATA Approximate Net Weight: 33-40 lbs. (15-18 kgs.) NOTES: 1 Not available in 175, 200, 320, 350 and 450W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC code requires that open luminaires must utilize a safety glass bottom (SGB) accessory or an open rated socket (OR) and lamp. 3 200, 250, 320, 350, 400 and 450W only. 4 277V only, not available with Q, EM, HL, HC, or HS option. 5 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 6 HPS only. 7 Products also available in non-US voltages and 50HZ for international markets. 8 Multi-tap ballast 120/208/240/277V wired 277V. 9 Triple-tap ballast 120/277/347V wired 347V. 10 5-tap ballast 120/208/240/277/480V wired 480V. 400W MH only. 11 Must be listed in order shown and separated by a dash. 12 Not available with QD, W, WL options. 13 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations for compatible lamps. For use with CWA ballast only. 14 Not available with QD PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 15 Not available with HL or HC option. 3 Indoor Lighting Solutions Cooper Lighting Aluminum High-Bay<<<INDUSTRIAL 150-450W HP/MH/MP/ML/MD HB VertX H E AV Y- D U T Y V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E Powered by technology 27" [686mm] A P P L I C AT I O N The HB VertX aisle lighter is ideal for higher mounting height warehouse applications. Its unique distribution pattern delivers high horizontal illumination while reducing “scallops” or hot spots for a more uniform vertical surface. 19" [483mm] LUMARK® O R D E R I N G I N F O R M AT I O N MOUNTING S A M P L E N U M B E R : H P H B - A V 1 9 - M - 4 0 0 - M T- Q Easy slide-on die-cast aluminum LAMP TYPE SERIES REFLECTOR TYPE HP=High HB=High-Bay AV=VertX Pressure Benchmark Sodium 1 MH=Metal Halide 2 MP=Pulse Start MH (CWA) 2, 3 ML=Pulse Start MH (Linear Reactor) 2, 3, 4 MD=Pulse Start Metal Halide (Electronic) 2, 5, 6 REFLECTOR DIAMETER 19=19" OPTIONS + ACCESSORIES SOCKET POSITION/ DISTRIBUTION 7 C=Concentrated M=Medium W=Wide LAMP WATTAGE 150=150W 8 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W 450=450W 9 VOLTAGE 10 OPTIONS + 120V ACCESSORIES 15 208V 11 (See Below) 11 240V 277V 11 347V 480V MT=Multi-Tap 12 TT=Triple-Tap 13 5T=5-Tap 14 E=Electronic 11 mounting box with tapped opening for 3/4" conduit. HOUSING Durable heavy-duty die-cast aluminum housing for lasting performance in the harshest environments. Integrally hinged for ease of maintenance with optional OPTIONS (add as suffix) 15 P=Pre-set Socket Position from the factory OR=Open Rated Socket for Metal Halide Lamps SS=Space Saver Feature QB=Quiet Ballast (Available on the Benchmark ballast housing only) QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3, MWS, RM or HC) RM=Remote Mount 16 TE=Toolless Entry HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 17 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 17, 18 HSW=Integral LumaWatt Sensor and with Wide Distribution Control for CWA Magnetic Ballast 17 LC=Low Voltage Control (0-10V DC Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit. Available with Benchmark housing and electronic HID ballast only—MD lamp type) 17, 19 LSW=Integral 0-10V Sensor and with Wide Distribution Control for ECONTM Electronic Ballast 17, 19 Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start) EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts) EM/SC=Quartz Restrike wired for Separate Circuit 5 F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240, or 480V only) FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1 or SHK. EXAMPLE: PC3-120V PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. EXAMPLE: PHC-120V-NEMA PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). EXAMPLE: PHC-NEMA C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK) MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. EXAMPLE: SCF6=6' Cable) SCR=Aircraft Safety Cable for Housing to Reflector L/TCB=Less Top Connector Box (Housing shipped less top connector box. Used when using TWMBS [Steeler Family] and TW [Benchmark Family] accessories) LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) toolless entry. Finished in a white polyester powder coat. BALLAST High-power factor ballast with class H insulation. Minimum starting temperature is -40°C (-40°F) HPS and -30°C (-20°F) for MH, MP, ML, and MD. UNIVERSAL BRACKETS Universal ladder brackets allow for the flexibility to change out with other reflectors available in acrylic ACCESSORIES (order separately) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1 or SHK PHC-XXXV=Power Cord and Plug 18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage or glass. TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240 or 480V) TW=Thru-way Mounting Box C3=3' Cord-No Plug-Requires FH-1, FL-1 or SHK MBT=Twin Mount Bracket (Fixtures must be same voltage,wattage and without hooks, loops or plugs) SOCKET Mogul-base porcelain socket. REFLECTOR Computer aided designed, field-adjustable reflector mounts easily and allows multiple distribution patterns for precise control. Special contours and unique system of facets minimizes NOTES: 1 Not available 175, 200, 320, 350 and 450W. 2 Approved lamp containment barrier required when enclosed rated MP/ML/MH lamps are used. 2005 NEC code requires that open luminaires must utilize a safety glass bottom (SGB) accessory or an Open rated socket (OR) and lamp. 3 200, 250, 320, 350, 400 and 450W only. 4 277V only, not available with Q or EM option. 5 Not available with HL or HC. 6 320, 350 and 400W only (See ECON section for list of current approved lamps at www.cooperlighting.com). 7 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 8 HPS only. 9 Standard 55°C ambient environments. 10 Products also available in non-US voltages and 50Hz for international markets. Consult factory for availability and ordering information. 11 MD available in 208, 240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. 12 Multi-tap ballast 120/208/240/277V wired 277V. 13 Triple-tap ballast 120/277/347V wired 347V. 14 5-tap ballast 120/208/240/277/480V wired 480V. 400W Metal Halide. 15 Must be listed in order shown and separated by a dash. 16 Not available with QD, W, WL option. 17 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations for compatible lamps. For use with CWA or ECONTM ballast only. 18 Not available with QD PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 19 Specify when using MD lamp type only. Cooper Lighting arc tube voltage rise. S H I P P I N G D ATA Approximate Net Weight: 35 lbs. (15 kgs.) Indoor Lighting Solutions 4 INDUSTRIAL>>>Aluminum High-Bay SE E&G VertX 150-450W HP/MH/MP/ML E N C L O S E D & G A S K E T E D V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E 31 3/16" [792mm] A P P L I C AT I O N The SE E&G VertX aisle lighter is ideal for higher mounting height warehouse applications. Its unique distribution pattern delivers high horizontal illumination while reducing “scallops” or hot spots for a more uniform vertical surface. 19" [483mm] LUMARK® MOUNTING O R D E R I N G I N F O R M AT I O N Easy slide-on die-cast aluminum S A M P L E N U M B E R : H P S E - E N A V 1 9 - M - 4 0 0 - M T- Q mounting box with tapped opening for 3/4" conduit. HOUSING Heavy-duty, formed steel housing with an open air ballast for cooler operation is finished in a white LAMP TYPE SERIES REFLECTOR TYPE HP=High ENAV=Enclosed & SE=E&G Pressure Gasketed VertX Sodium 1 VertX MH=Metal Halide 2 MP=Pulse Start MH (CWA) ML=Pulse Start MH (Linear Reactor) 2, 3 REFLECTOR DIAMETER 19=19" polyester powder paint. SOCKET POSITION/ DISTRIBUTION 4 C=Concentrated M=Medium W=Wide LAMP WATTAGE 150=150W 5 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W 450=450W VOLTAGE 6 OPTIONS + 120V ACCESSORIES 10 208V (See Below) 240V 277V 347V 480V MT=Multi-Tap 7 TT=Triple-Tap 8 5T=5-Tap 9 BALLAST High power factor ballast with class H insulation. Minimum starting temperature is -40°C (-40°F) for HPS and -30°C (-20°F) for MH, MP and ML. SOCKET Mogul-base porcelain socket. NECK Die-cast aluminum neck with staggered mounting bosses for eight-position adjustability of the socket which provides a variety of distributions from concentrated to wide. REFLECTOR Computer aided designed, reflector mounts easily and allows multiple distribution patterns for precise control. Special contours and unique system of facets minimizes arc tube voltage rise. LENS OPTIONS + ACCESSORIES OPTIONS (add as suffix) 10 P=Pre-set Socket Position from the factory SS=Space Saver Feature QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3, MWS, RM or HC) RM=Remote Mount 11 HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 12 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 12, 13 HSW=Integral LumaWatt Sensor and Control with Wide Distribution for CWA Magnetic Ballast 12 Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start) EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts) EM/SC=Quartz Restrike wired for Separate Circuit 14 F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240, or 480V only) FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1 or SHK. EXAMPLE: PC3-120V ACCESSORIES (order separately) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 277V-L7-15P, 347V-L3720P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1, or SHK PHC-XXXV=Power Cord and Plug 18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. EXAMPLE: PHC-120V PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). EXAMPLE: PHC-120V-NEMA C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK) MW=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. EXAMPLE: SCF6=6' Cable) SCR=Aircraft Safety Cable for Housing to Reflector L/TCB=Less Top Connector Box (Housing shipped less top connector box. Specify when using TWMBS accessory) LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (120, 277, or 347V) TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage (208, 240 or 480V) TWMBS=Thru-way Mounting Box C3=3' Cord-No Plug-Requires FH-1, FL-1, or SHK MBT=Twin Mount Bracket (Fixtures must be same voltage,wattage and without hooks, loops or plugs) WG19/SGB/AV=Wire Guard with Safety Glass Bottom Clear tempered glass lens in an extruded aluminum hinged door frame with latches to allow access for relamping without tools. S H I P P I N G D ATA Approximate Net Weight: 38-50 lbs. (17-23 kgs.) NOTES: 1 Not available in 175, 200, 320, 350 and 450W. 2 175, 200, 250, 320, 350, 400, 450W only. 3 277V only, not available with Q, EM, HL or HC option. 4 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 5 HPS only. 6 Products also available in non-US voltages and 50HZ for international markets. 7 Multi-tap ballast 120/208/240/277V wired 277V. 8 Triple-tap ballast 120/277/347V wired 347V. 9 5-tap ballast 120/208/240/277/480V wired 480V. 400W MH only. 10 Must be listed in order shown and separated by a dash. 11 Not available with QD, W, WL options. 12 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations for compatible lamps. For use with CWA ballast only. 13 Not available with QD PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 14 Not available with HL or HC option. 5 Indoor Lighting Solutions Cooper Lighting Aluminum High-Bay<<<INDUSTRIAL 175-450W HP/MH/MP/ML/MD EB E&G VertX H E AV Y- D U T Y E N C L O S E D & G A S K E T E D V E R T I C A L A I S L E L I G H T E R H I G H - B AY L U M I N A I R E Powered by technology 30" [762mm] A P P L I C AT I O N The EB E&G VertX aisle lighter is ideal for higher mounting height warehouse applications. Its unique distribution pattern delivers high horizontal illumination while reducing “scallops” or hot spots for a more uniform vertical surface. 19" [483mm] LUMARK® O R D E R I N G I N F O R M AT I O N MOUNTING S A M P L E N U M B E R : H P E B - E N A V 1 9 - M - 4 0 0 - M T- Q Easy slide-on die-cast aluminum mounting box with tapped opening LAMP TYPE SERIES REFLECTOR TYPE HP=High ENAV=Enclosed EB=E&G VertX Pressure & Gasketed Sodium 1 VertX MH=Metal Halide 2 MP=Pulse Start MH (CWA) ML=Pulse Start MH (Linear Reactor) 2, 3 MD=Pulse Start Metal Halide (Electronic) 2, 4 REFLECTOR DIAMETER 19=19" SOCKET POSITION/ DISTRIBUTION 5 C=Concentrated M=Medium W=Wide LAMP WATTAGE 150=150W 6 175=175W 200=200W 250=250W 320=320W 350=350W 400=400W 450=450W VOLTAGE 7 OPTIONS + 120V ACCESSORIES 12 208V 8 (See Below) 240V 8 277V 8 347V 480V MT=Multi-Tap 9 TT=Triple-Tap 10 5T=5-Tap 11 E=Electronic 8 for 3/4" conduit. HOUSING Durable heavy-duty die-cast aluminum housing for lasting performance in the harshest environments. Integrally hinged for ease of maintenance with optional toolless entry. Finished in a white OPTIONS + ACCESSORIES OPTIONS (add as suffix) 12 PS=Protective Starter (Available in 1000W HPS only. For other wattages, consult factory) SS=Space Saver Feature QB=Quiet Ballast (Available on the Benchmark ballast housing only) QD=Quick Disconnect Die-cast Pendant Mount Box (Specify Single Voltage, Not compatible with PC3, PHC, C3, MWS, RM or HC) RM=Remote Mount 13 TE=Toolless Entry HL=LumaWatt Fixture Control Module (Allows low voltage control wire to be daisy-chained between fixtures outside AC conduit run similar to low voltage intercom’s, fire alarms and phone systems) 14 HC=LumaWatt Fixture Control Module (Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit) 14, 15 HSW=Integral LumaWatt Sensor and with Wide Distribution Control for CWA Magnetic Ballast 14 LC=Low Voltage Control (0-10V DC Low voltage leads pulled out of top connection box for areas requiring all wiring to be installed in conduit. Available with Benchmark housing and electronic HID ballast only—MD lamp type) 14, 16 LSW=Integral 0-10V Sensor and with Wide Distribution Control for ECONTM Electronic Ballast 14, 16 Q=Quartz Restrike DC Bayonet Base (Quartz lamp will not come on at initial cold start) EM=Quartz Restrike with "Delay Relay" (Lamp strikes at both hot and cold starts) EM/SC=Quartz Restrike wired for Separate Circuit 3 F1=Single Fuse (120, 277 or 347V only) F2=Double Fuse (208, 240, or 480V only) FILT=Sintered Bronze Filter (Sintered bronze filter prevents the entrance of contaminants) FH-1=Die-cast Aluminum Fixture Hook (with 3/4" threads for easy installation) FL-1=Malleable Iron Plated Fixture Loop (with 3/4" threads for easy installation) SHK=Die-cast Aluminum Fixture Hook (with safety screw and 3/4" threads for easy installation) polyester powder coat. BALLAST PC3-XXXV=3' cord with NEMA plug (120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, AND 480V-L820P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1, or SHK. EXAMPLE: PC3-120V PHC-XXXV=Power Cord and Plug (18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must specify single voltage. EXAMPLE: PHC-120V-NEMA PHC-XXX-NEMA=Power Cord and NEMA Plug] 18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook). EXAMPLE: PHC-NEMA C3=3' Cord with no plug (Must use with FH-1, FL-1, or SHK) MWS=MWS Industrial components attached to the fixture at the factory. (Standard cord length is 3 ft., 6 ft. and 11 ft. also available. Please refer to MWS Modular Wiring System section for additional information) SCF=3' Aircraft Safety Cable secures Housing to Ceiling (Alternative lengths available. EXAMPLE: SCF6=6' Cable) SCR=Aircraft Safety Cable for Housing to Reflector L/TCB=Less Top Connector Box (Housing shipped less top connector box. Used when using TWMBS [Steeler Family] and TW [Benchmark Family] accessories) LL=Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) QLL=Quartz Lamp Included (Lamp is Cooper designated product based on luminaire requirements. Lamp is shipped separate from luminaire unless otherwise noted) WL=Wet Location Listed Luminaires 17 High-power factor ballast with class H insulation. Minimum starting temperature is -40°C (-40°F) HPS and -30°C (-20°F) for MH, MP, ML, and MD. SOCKET Mogul-base porcelain socket. NECK Die-cast aluminum neck with staggered mounting bosses for eight-position adjustability of the socket which provides a variety of distributions from concentrated to wide. ACCESSORIES (order separately) FH-1=Fixture Hook FL-1=Fixture Loop SHK=Hook with Safety Screw PC3-XXXV=3' Cord with NEMA Plug—(120V-L5-15P, 208V-L6-15P, 240V-L6-15P, 347V-L37-20P, and 480V-L8-20P) Other cord lengths are available by specifying length (PC6 for 6’ cord). Requires FH-1, FL-1, or SHK PHC-XXXV=Power Cord and Plug—18" Power Cord and Non-NEMA plug configuration. Must be used with FL-1 and TPPH (Thru-Way Pendant Power Hook). Must Specify Single Voltage PHC-XXXV-NEMA=Power Cord and NEMA Plug—18" Power Cord and 20 Amp NEMA plug configuration. Must be used with FL-1 and TPPH-NEMA (Thru-Way Pendant Power Hook) TPPH-XXXV-NEMA=Thru-way Pendant Power Hook. Requires FL-1 and PHC-XXXV-NEMA. Specify Voltage TPPH-XXXV=Thru-Way Pendant Power Hook Requires FL-1 and PHC. Specify Voltage REFLECTOR TPPH-F-XXXV=Thru-Way Pendant Power Hook–Single Fuse, 120, 277 or 347 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F2-XXXV=Thru-Way Pendant Power Hook–Double Fused, 208, 240 or 480 Volt. Requires FL-1 and PHC. Specify Voltage TPPH-F-QD-XXXV=Thru-Way Pendant Power Hook–Single Fuse, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage TPPH-F2-QD-XXXV=Thru-Way Pendant Power Hook–Double Fused, Quick Disconnect. Requires FL-1 and PHC. Specify Voltage C3=3' Cord-No Plug-Requires FH-1, FL-1, or SHK MBT=Twin Mount Bracket (Fixtures must be same voltage, wattage, and without hooks, loops or plugs) TW=Thru-way Mounting Box WG19/SGB/AV=Wire Guard with Safety Glass Bottom Computer aided designed, reflector mounts easily and allows multiple distribution patterns for precise control. Special contours and unique system of facets minimizes arc tube voltage rise. LENS Clear tempered glass lens in an extruded aluminum hinged door frame with latches to allow access for relamping without tools. NOTES: 1 Not available in 175, 200, 320, 350 and 450W. 2 200, 250, 320, 350 and 450W only. 277V only, not available with Q or EM option. 3 Not available with HL or HC. 4 Electronic available in 320, 350 and 400W only. (See ECON section for list of current approved lamps at www.cooperlighting.com). 5 Factory set for concentrated, medium or wide distributions only if P (factory pre-set) is in the nomenclature of the fixture. 6 HPS only. 7 Products also available in non-US voltages and 50Hz for international markets. Consult your Cooper Lighting Representative for availability and ordering information. 8 MD available in 208, 240 or 277V or with “E” option which will operate voltages from 200-277V 50/60 Hz. 9 Multi-tap ballast 120/208/240/277V wired 277V. 10 Triple-tap ballast 120/277/347V wired 347V. 11 5-tap ballast 120/208/240/277/480V wired 480V. 12 Must be listed in order shown and separated by a dash. 13 Not available with QD, W, WL option. 14 30 second time delay when switching from bright to dim. Consult individual lamp manufactures recommendations for compatible lamps. For use with CWA or ECONTM ballast only. 15 Not available with QD PC3, C3, PHC or MWS. Not available with single circuit MWS special order. 16 Specify when using MD lamp type only. 17 Not available with HL, HC, HSW, LC, and LSW options. Cooper Lighting S H I P P I N G D ATA Approximate Net Weight: 34-47 lbs. (15-21 kgs.) Indoor Lighting Solutions 6 CUSTOMER FIRST CENTER 1121 HIGHWAY 74 SOUTH PEACHTREE CITY, GEORGIA 30269 770 486 4800 FAX 770 486 4801 Domestic Facilities, USA Cranbury, New Jersey Elk Grove Village, Illinois Irving, Texas Ontario, California Peachtree City, Georgia International Sales, USA Peachtree City, Georgia CANADA Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 905 507 4000 FAX 905 568 7049 Domestic Facilities, Canada Calgary, Alberta Chomedey, Laval P.Q. The Cooper Lighting Family Halo Cooper Lighting - Metalux Cooper Lighting - Lumark Cooper Lighting - Sure-Lites Neo-Ray Corelite Portfolio Iris Shaper Lumière Invue McGraw-Edison Fail-Safe MWS DLS RSA Ametrix VertX Vertical Aisle Lighter High-Bay Luminaire Cooper Lighting, Inc. All rights reserved Printed in USA www.cooperlighting.com ADH050438