Installation Instructions Dual Technology Wall/Corner Mounted Low Voltage Occupancy Sensor Model # OAWC-DT-120W Model # OAWC-DT-120W-R P/N 9850-000137-01 Location • ForUsewithGreengateSwitchpacks&Systems Only • DonotrunanyGreengateLowVoltageWiringin thesameconduitaspowerconductors Specifications Technology:PassiveInfrared(PIR)andUltrasonic(US) Power Requirements: Input: • 10-30VDCfromGreengateSwitchpackorGreengate system.Maximumcurrentneededis25mApersensor Output: • OpencollectoroutputtoswitchuptotenGreengate Switchpacks.BASwithIsolatedFormCRelay(-R model)IsolatedFormCRelayRatings:1A30VDC/VAC Time Delays:Self-Adjusting,15seconds/test(10minAuto) orSelectable5,15,30minutes Coverage:1200sq.ft. Light Level Sensing:0to300foot-candles(-Rmodel) Operating Environment: • Temperature:32°F–104°F(0°C–40°C) • RelativeHumidity:upto90%non-condensing Housing: • Mediumimpactinjectionmoldedhousing • PolycarbonateresincomplieswithUL94V0 Size:4.4"x3.4"x2"(112mmx86.4mmx50.8mm) LED Indicators:RedindicatesPIRdetection;Green indicatesUltrasonicdetection Themaximumcoverageareamayvarysomewhataccordingtoroomshapeand thepresenceofobstacles.Followthecoveragediagramconcerningmajorandminor motioncoverage.Decreasetotalcoverageareaby15%for“soft”rooms(forexample, heavydraperiesorheavycarpeting).Thesensormusthaveaclearviewofthearea tobecontrolled.Thesensorwillnot“see”throughglass.Mountingheightshouldnot exceed12feet.Optimummountingheightis10feet.Mountthesensorsothegrilles facetheopenportionoftheroomandarenotfacinganearbywall,door,windowor otherobstructingobject.Avoidpointingintohallways.Topreventfalseactivation,the sensorshouldbemountedawayfromtheairsupplyductaminimumof4to6feet. Mountingatfixtureheightismosteffective.FortypicalplacementrefertoLocation Diagram. Location Diagram Installation Wiring TheOAWC-DT-120Wcanbemountedtothewall,ceiling,junctionbox,orroundfixturewithraceway. Description 1. MakesurepoweristurnedOFFatthebranchcircuitbreaker. 2. Wireunitsasshowninwiringdiagramsperapplicablevoltagerequirements.(Usetwist-onwireconnectorsforall connections)CAPALLUNUSEDWIRELEADS. 3. Mountunittowall,ceiling,junctionboxorroundfixturewithraceway. 4. TurnpowerbackONatthebranchcircuitbreakerandwaittwominutesfortheunittostabilize. 5. Makenecessaryadjustments.(SeeCheckoutandAdjustmentssection) Occupancy Sensor Mounted to Wallboard Occupancy Sensor Mounted to Drop Ceiling Hot Occupancy Sensor Mounted to Octagon Box 12’ (3.7) Minor Motion, IR 8’ (2.4 mm) Major Motion, IR 0 Minor Motion, Ultrasonic 8’ (2.4 mm) Major Motion, Ultrasonic One Sensor, One Switchpack Line Coverage 24’ (7.3 mm) 20’ (6 mm) CAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at the branch circuit breaker. According to NEC 240-83(d), if the branch circuit breaker is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked “SWD”. All installations should be in compliance with the National Electric Code and all state and local codes. NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the effects of cycling. SENSOR WIRE LEAD LEGEND Neutral Black (Common) Red (10-30 VDC) **Use Black Lead for 120 VAC Blue (Control) Use Orange Lead for 277 VAC Yellow (Control) Cap Unused Lead Black (Common) Brown (Switch-Blue Lead Control) Blue Brown/White (Switch-Yellow Lead Control) Red (15 VDC) Blue (Control) Sensor’s Isolated Relay Switchpack Orange (Normally Open) Gray (Common) To Additional Sensors. Purple (Normally closed) Maximum of 5 sensors per switchpack. **Hot TheOAWC-DTWall/CornerMountLowVoltageOccupancySensorisaPassiveInfrared(PIR)andUltrasonic(US)motion sensinglightingcontrol,usedforenergysavingsandconvenience.PIRisusedtoturnthelightsONandtheneitherorboth technologiesareusedtokeepthelightsON.Whenmotionisdetected,thebluewireiselectronicallyconnectedtothered wire,energizingtherelayintheswitchpacktoturnONtheload.Ifvacancyisdetected,thebluewireisdisconnectedfrom thered,causingtherelaytoopenturningOFFtheload.Theredleadis10-30VDCsupply,theblackleadiscommonandthe blueistherelaycontrol. Thesensorincludesself-adaptivetechnologythatcontinuallyadjuststoconditionsbyadjustingsensitivityandtimedelay inreal-time. TheDaylightingfeature(-Rmodelonly)preventslightsfromturningONwhentheroomisadequatelyilluminatedby naturallight. TheWalk-ThroughfeaturemaximizesenergysavingsbynotleavingthelightsONaftermomentaryoccupancy.Thesensor willswitchthelightsONwhenitdetectsapersonenteringthearea.Ifthesensordoesnotcontinuetodetectmotion30 secondsfollowingtheinitialactivation,itwillautomaticallygotoashorter2minutetimedelay. InAutomaticONMode,thelightsturnONwhenapersonenterstheroom.InManualOnMode,thelightsareturnedON byactivatingamomentaryswitch(model#GMDS-*)thatisconnectedtothesensor.Whenusedwith2levellighting (-Rmodelonly),bi-levelAutomaticONcanbeachievedwhichallowsZone1tocomeONautomaticallyuponoccupancy. Zone2doesnotcomeONunlesstheoccupantpressestheoptionalmomentaryswitch. Occupancy Sensor Mounted to Round Fixture with Raceway Maximum coverage area may vary somewhat according to room shape and the presence of obstacles. The NEMA WD 7 Guide and robotic method were utilized to verify coverage patterns. Black Red Blue Yellow Brown Brown/White Orange Gray Purple Blue • Readallinstructionsonbothsidesofthissheet first • InstallinaccordancewithALLlocalcodes • Forindooruseonly White General Information Load 1 Optional Greengate GMDS SwitchBlue Control Lead-Manual ON/OFF Recommended Wire: 18-3 AWG stranded non-shielded 12’ (3.7) 10 ft (3 mm) 24’ (7.3 mm) 20’ (6 mm) 6 ft 15 ft (1.7 mm) (4.6 mm) 24 ft (7.3 mm) 50 ft (15.3 mm) Occupancy Sensor Mounted to Octagon Box with Mud Ring Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com One Sensor, Multiple Switchpacks Hot Hot Line Black(Common) Red (15VDC) Blue (Control) Switchpack Sensor's Isolated Relay Orange (Normally Open) Gray (Common) Purple (Normally Closed) Black(Common) Red (15VDC) Blue (Control) Switchpack Blue Blue White Neutral **Use Black Lead for 120VAC Use Orange Lead for 277VAC Load 1 Cap Unused Lead Blue **Use Black Lead for 120VAC Use Orange Lead for 277VAC Cap Unused Lead White Neutral **Hot Line **Hot SENSOR WIRE LEAD LEGEND Black (Common) Red (10-30VDC) Blue (Control) Yellow (Control) Brown (Switch-Blue Lead Control) Brown/White(Switch-Yellow Lead Control) PIR Sensitivity 1. Standindifferentareasoftheroomandwaveyourhands. 2. IftheRedLEDdoesnotturnON,checkforanyobstructions. 3. Standstillsixtoeightfeetawayfromsensorforfiveseconds.LEDshouldnotturnON. 4. IfRedLEDturnsONwithoutmotionorisconstantlyONadjustPIRsensitivityto50%bymovingDIPswitch5UP. Load 2 Blue To Additional Switchpacks 10 switchpacks Maximum Black Red Blue Yellow Brown Brown/White Orange Gray Purple Field-of-view outside the space 1. AdjustPIRsensitivityto50%bymovingDIPswitch5UP. 2. AdjustUltrasonicSensitivity. Daylight Adjustments (-R model only) Ifthisfeatureisnotneeded,leavethelightlevelatmaximum(fullyclockwise). TheDaylightingfeaturepreventsthelightsfromturningONwhentheroomisadequatelyilluminatedbynaturallight.Ifthere isenoughlightintheroomregardlessofoccupancy,thesensorwillholdthelightsOFF.Ifthereisnotenoughlightintheroom, thesensorwillallowthelightstoturnONwhenoccupied. Optional Greengate GMDS SwitchBlue Control Lead- Manual on/off Full and Half Logic Modes(SeeDIPswitchlegend): InbothFullandHalfLogicmodes,lightsconnectedtotheyellowcontrolleadwillnotturnONuponoccupancyactivation, shouldtheambientlightlevelexceedthepresetfoot-candlelevel. DIP Switch Settings Time Delay DIP Switch Activation Power Pack One Activation PIR Sensitivity Walk-Through Mode LEDs Override Lighting Sweep Daylighting Mode Power Pack Two (-R model only) (-R model only) 1 2 3 4 5 6 7 8 9 10 Checkout and Adjustment AdjustmentsshouldbemadewiththeHVACsystemON.Useonlyinsulatedtoolstomakeadjustments. Self-Adjust SensorisshippedintheSelf-AdjustMode.Thisappliestotimedelay,US,andPIRsensitivity.Inpreparationforthe InstallerTest,thetimedelayissetto15seconds,afterthesensorisinstalled,poweredONandhasstabilized,theunitwill time-out15secondsafterthelastmotiondetected.CoverageandsensitivitycanbeconfirmedbywatchingtheGreen(US) andRed(PIR)indicatorLEDsonthefrontofthesensor,whilemovingaroundtheroom. 1. WalkaroundtheroomandmonitorLEDs.LEDsshouldonlyturnONforonesecondwitheachmotion.(IfLEDsdonot turnON,gotoInstallerAdjustments-SensitivityAdjustmentsSection) 2. Standstillsixtoeightfeetawayfromthesensorforfiveseconds.LEDsshouldnotturnON.(IfanyLEDturnsON,note LEDandgotoInstallerAdjustments–SensitivityAdjustmentsection) 3. Walkoutsidetheroomandwait15secondsforthelightstoturnOFF.(IflightsdonotturnOFFgotoInstaller AdjustmentsSection) 4. Re-entertheroomtoactivatesensor.(IflightsdonotturnONgotoTroubleshootingSection) 5. TheunitwillremaininTestModefor5 minutesthenautomaticallyexitTestModeandgofor10min.TimeDelayUser Modesetting. Note:ToplaceintoTestMode,toggleDIPSwitch10outofitscurrentposition,wait3seconds,andthenbackintoitsoriginalposition.Toforce into10minUserModemoveDipSwitches1and2down.(IfDIPSwitches1and2arealreadydown,toggleDIPSwitch1outofitscurrentposition, wait3seconds,andthenbacktoitsoriginalposition)WhileinTestMode,theLEDswillflashonceper1/4second. Installer Adjustments Sensitivity Adjustments Ultrasonic Sensitivity(GreenLED)–Usingasmallflatheadscrewdriverturnthegreenpotentiometersothatthearrow pointsUP. 1. Standindifferentareasoftheroomandwaveyourhands. 2. IftheGreenLEDdoesnotturnON,increasetheUSsensitivitybyturningthegreenpotentiometerclockwiseinsmall increments.RepeatStep1. 3. Standstillsixtoeightfeetawayfromsensorforfiveseconds.LEDshouldnotturnON. 4. IfGreenLEDturnsONwithoutmotionorisconstantlyONdecreasetheUSsensitivitybyturningthegreen potentiometercounter-clock-wiseinsmalldecrements.RepeatStep3. Troubleshooting Issue Lights Will Not Turn ON automatically Lights Will Not Turn ON manually Time Delay Adjustments PeoplewhoremainverystillforlongperiodsoftimemayneedalongerTimeDelaythanthedefaultsettingof10minutes. AslongasAutoisenabled,thesensorwillrespondtoeachpairoffalse-OFFswithnonormalOFFinbetween,byalternately makingslightadjustmentstoeithertimedelay(by2minuteincrements)orsensitivity,sothereshouldbenoneedformanual adjustment.Ifmanualadjustmentisdesired,refertoTimeDelaysettingsinDIPswitchlegend. ResetsensortimedelaytofactorysettingsbymovingDIPswitches1and2down.(IfDIPswitches1and2arealreadydown, toggleDIPswitch1outofitscurrentposition,wait3seconds,andthenbacktoitsoriginalposition) Automatic Mode InAutomaticONMode,thelightsturnONwhenapersonenterstheroom.Ifoptionalmomentarylowvoltageswitchesare usedalongwithAutomaticONMode,activatingtheswitch(es)whiletheloadisONturnstheloadOFF.Whentheloadisturned OFFmanually,aslongasthesensorcontinuestodetectoccupancytheloadsstayOFF.Afterthetimedelayexpires,thelights stayOFFandthesensorgoesbacktoAutomaticONMode.Forwiringinformationfortheoptionalmomentarylowvoltage switch(es),pleaseseethewiringsectionoftheinstallationinstructions. Manual Mode InManualONMode,theoptionalmomentarylowvoltageswitch(es)isrequiredtoturntheload(s)ON.Onceactivatedthe sensorwillmaintainthelightsONuntilmotionceasesandthetimedelayexpires.WhiletheroomisoccupiedtheBASrelay remainsactive.Afterthetimedelayexpires,theload(s)willautomaticallybeturnedOFFandtheswitch(es)mustbeusedtoturn theload(s)ONunlessthereismotiondetectedwithinthe10secondre-triggerperiod. Suggestions WallSwitchOFF TurnWallSwitchON Iflowvoltageswitchoptionisused,lights mayhavebeenturned-offmanually Presslow-voltageswitch DaylightingFeatureEnabled IfalllightsarerequiredtoturnONadjustDIP Switch10and/ordaylightpotentiometer Powerinterruption Checkincomingvoltageand/orwiring DaylightingFeatureEnabled IfalllightsarerequiredadjustDIPswitch 10and/ordaylightpotentiometer Powerinterruption Checkincomingvoltageand/orwiring If lights will still not turn ON, set sensor to override mode and call Technical Services at 1-800-553-3879 After activation: FullLogicMode–shouldtheambientlightlevelexceedthepresetfoot-candlelevel,thelightsconnectedtotheyellow controlleadwillturnOFF.ThelightswillremainOFF,untiltheambientlightlevelfallsbelowthesetpoint. HalfLogicMode–theoutputstateoftheyellowcontrolleadwillnotchangewithambientlightchanges,afteroccupancy activation.Iftheamountofnaturallightavailablerisesabovethesetpoint,thedaylightsensorwillnotturnthelightsOFFwhile occupancyisbeingdetected. Note:Setthelightlevelwhentheambientlightisatthelevelwherenoartificiallightisneeded.Inorderforthisfeatureto function,theyellowcontrolleadmustbewired. 1. WiththeloadON,putthesensorintoTestMode.ToplaceintoTestMode,toggleDIPswitch10outofitscurrentposition, wait3secondsandthenbackintoitsoriginalposition. 2. SetDIPswitch10toFullorHalfLogicMode. 3. Setthelightleveltominimum(fullyCCW). 4. Leavetheroomandletthesensortime-outsolightsareOFF.EnterthespaceandlightsshouldremainOFF. 5. MakesurenottoblockthesensorfromthedaylightsourceandadjustthelightlevelpotentiometerCWinsmallincrements untilthelightsareON.(Pause5secondsbetweeneachadjustment) 6. OncethelightsareON,theloadconnectedtothesensorwillnotturnONiflightlevelsareabovethecurrentillumination. Possible Causes Lights Will Not Turn OFF automatically Lights Will Not Turn OFF automatically Override MakesuresensorisnotinOverrideMode(DIPSwitch8up) UltrasonicSensitivitysetHigh Lowersensitivitybyturninggreen potentiometerCCWinsmalldecrements Sensorinstalledclosetoanairvent Sensorsshouldbeinstalledminimum4-6feetaway fromanyairventandoutofpathofheavyairflow Sensorinstalledclosetoindirectlighting Sensorsshouldbemountedawayfromindirectlighting. Self-adjust Itmaybepossiblefortheunittohaveself-adjusted thetimedelaytoa30minutedelay.Ifthelightsdo notturnOFFafter30minutesfollownextstep 30MinuteDelay Maximumtimedelayis30Minutes.CheckDIP SwitchestoverifyDIPSwitchsettings.Iflightsdo notturnOFFatthesettimedelay,checknextstep PIRactivatedbyheat sourceotherthanoccupant MoveDIPSwitch5up Bypass Checkwiringtomakesuresensoror switchpackarenotbypassed Override MakesuresensorisnotinOverrideMode(DIPSwitch8up) If lights will still not turn OFF, call Technical Services at 1-800-553-3879 Warranties and Limitation of Liability Pleaserefertowww.coopercontrol.comundertheLegalsectionforourtermsandconditions. Lighting Sweep Option Ifselected,thisDIPswitchoptionforcesaninitial60seconddelayupon“power-up”topreventfalseactivationinbuildings withcomputercontrolsystems. 1. MoveDIPswitch9UP. Override TheOverridesettingallowsthelightstoremainONintheunlikelyeventofsensorfailure. 1. MoveDIPswitch8UP. WhileinOverrideMode,theoptionallowvoltagemomentaryswitch(es)willtogglethelightingload(s). Printed in Malaysia Eaton’s Cooper Controls Business 203 Cooper Circle Peachtree City, Georgia 30269 www.coopercontrol.com