Download B280-05004

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stray voltage wikipedia , lookup

Control theory wikipedia , lookup

Loading coil wikipedia , lookup

Power engineering wikipedia , lookup

Buck converter wikipedia , lookup

Distributed control system wikipedia , lookup

Telecommunications engineering wikipedia , lookup

History of electric power transmission wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Metadyne wikipedia , lookup

Resilient control systems wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Control system wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Power over Ethernet wikipedia , lookup

Electrical substation wikipedia , lookup

Rectiverter wikipedia , lookup

Mains electricity wikipedia , lookup

Distribution management system wikipedia , lookup

Transcript
COOPER POWER
SERIES
Kwik-Ship reclosers
Kwik reliability with Kwik-Ship reclosers,
and Form 6 or Form 4D control
Eaton is pleased to offer
its Kwik-Ship program for
Cooper Power™ series
NOVA™ recloser and
control shipments. This
program uses production
planning techniques and
sales inputs to provide
immediate shipment
of complete advanced,
automation-ready, polemounted or substation
reclosers within 2-4
weeks.
How to Order:
Reclosers
Review NOVA recloser
and control specifications
and check appropriate
requirements.
ü
Controls
NOVA Recloser
Catalog Number:
KNOVA27AKwik
Form 6 Pole-Mount
•
NOVA recloser: 3-Phase, 27 kV,
125 kV BIL, 800 A, 12.5 kA,
120 Vac Auxiliary-Powered
•
Eyebolt terminals 1/0
to 500 MCM
•
Input power cable, KA11ME1XX
Cable length _____ (10-50 ft, in five feet increments)
Control Catalog Number:
KME6P2AKwik
•
Form 6 pole-mount control:
120 Vac auxiliary-powered
•
Mild steel cabinet
•
120/240 V 3-wire (8 A hour
battery)
•
Serial fiber-optic
communication port
•
Basic automation provisions
including radio mounting
bracket and 24 Vdc/13.8 Vdc
converter
•
Convenience outlet
•
KA1MEXX control cable
Options
The Kwik-Ship NOVA program
applies to orders with these
specifications only. Additional
accessories may be added
with a longer leadtime. For
larger quantities or if you need
additional information, contact
your Eaton representative.
For a Kwik-Ship quote contact
your Eaton representative.
KNOVA54-3 pole frame
with load- and source-side
arrester brackets (KNOVA61-1 or NOVA61-2)
KNOVA59-1 substation frame KNOVA848 Internal Voltage Sensors (IVS)
KA97ME voltage sensing
cable (only used when
KNOVA848 is required)
IVS cable length _____ (10-50
ft, in five feet increments)
Cable length _____ (10-50 ft, in five feet increments)
Standard I/O contacts
Options
Internal Voltage Sensing
receptacle (required when
IVS is ordered)
Form 4D Pole-Mount
Control Catalog Number: KME4DPAKwik
•
Form 4D pole-mount control
•
Mild steel cabinet
•
120/240 V 3-wire (8 A hour
battery)
•
DNP3 Protocol on RS-232
Port 1
•
KME4D-1776 convenience
outlet
•
KME4D-1774-21
communications power supply
•
KA1MEXX control cable
Cable length _____ (10-50 ft, in five feet increments)
Options
KME4D-3799 Internal Voltage
Sensing (IVS) receptacle
(required when IVS is
ordered)
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
For Eaton’s Cooper Power series product
information call 1-877-277-4636 or visit:
www.eaton.com/cooperpowerseries.
Eaton’s Cooper Power Systems Division
2300 Badger Drive
Waukesha, WI 53188
United States
Eaton.com/cooperpowerseries
© 2015 Eaton
All Rights Reserved
Printed in USA
Publication No. PA280006EN June 2015
Supersedes B280-05004 August 2012
Eaton, Cooper Power, and NOVA are valuable
trademarks of Eaton in the U.S. and other
countries. You are not permitted to use these
trademarks without the prior written consent
of Eaton.