Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Spectrometric Diagnosis Group in Plasma Chemistry and Physics 박영동1, 오수기2 1Department of Chemistry, 2Department of Physics, Ajou University, Suwon 443-749, Korea Vision/Mission High Resolution Spectroscopy/Optical Diagnosis Group Chemistry Laser Spectroscopy Molecular Beam Spectroscopy Photoionization Spectroscopy Physics Interferometry Optics Fabry-Perot Atomic and Plasma Physics Stength/Capacity Chemistry Molecular Spectroscopy Theoretical Spectroscopy Physics Optics – Fourier optics, interferometry Plasma Physics Tokamak Plasma The magnetic field lines inside the tokamak chamber are divided into two groups: the magnetic separatrix surface One forming nested closed surfaces in the main chamber without touching the material wall the “core” region hot and dense the other leading to the divertor chamber the “scrape-off” region cold and diluted The heating effect of the electric current, joule-heating, is less than 50 million degrees. The need for additional heating has led to neutral beam heating. CXS is an appropriate tool to measure the effect of neutral beam heating. The Charge Exchange Recombination Spectroscopy (CXRS) ion temperature Doppler broadening poloidal and toroidal rotation speed Doppler shift impurity density total intensity H0 + C6+ → H+ + [C5+]* charge exchange between neutrals in the neutral beams and ions in the plasma CXRS system in JT-60U Doppler Broadened Data Fabry-Perot interferometer Mirrors Photon counter Piezo actuator Design of a spectrograph system for temperature measurement in Fusion Reactor using Doppler Broadening Fabry-Perot interferometer system Advantages can achieve very high spectroscopic resolution Disadvantages 1. Need very sharp filter to separate photones outside of free spectral range 2. input beam should be stable during scan period. 3. hard to employ large aperture system McPherson Model 2062 2-meter focal length f/14.1 Monochromator, $200,000 McPn CXRS Grating Groove Density (g/mm) 1200 Resolution** (nm) 0.005 Dispersion (nm/mm) 0.4 AJOU CXRS 50 cm C C D Focusing Mirror Grating 2 1800 gr/mm 1st order Grating 1 1200 gr/mm -1st order Light Source Collimating Mirror Entrance Slit 50000 Grating Groove Density (g/mm) 1200+1800 Resolution** (nm) 0.007 Dispersion (nm/mm) 0.7 Intensity(a.u.) 40000 0.07 A FWHM fitted experimental data 30000 20000 10000 0 531.95 532.00 Wavelength(nm) 532.05 AJOU CXRS AJOU CXRS AJOU CXRS Ne I =529.8189 nm Ne I =530.4758 nm Ne I =528.0085 nm FIG. 4. The measured Ne I spectrum lines by the two-grating spectrometer equipped with the PhotonMax 512B CCD camera. AJOU CXRS Conventional (80 ms, 1760 McPherson spectrometer(80 ms)mm) Ajou two-grating ms) Two-grating (96spectrometer(46 ms, 1720 mm) Intensity (a. u.) 200 McPn CXRS 150 The Ajou system is ~10 times better in S/N for a fraction of the cost for ‘old’ system. 100 50 0 528.5 529.0 529.5 530.0 Wavelength (nm) FIG. 5. The spectrum signals are obtained with the two-grating spectrometer (triangle) and conventional spectrometer (square) for the KSTAR plasma. It is shown that the S/N ratio of the two-grating spectrometer is much larger than that of the conventional spectrometer. 1.6 (a) Ti (keV) 1.2 0.8 Ajou 0.4 Conventional (1.70 s) Two-grating (1.75) 0.0 1.7 1.8 1.9 2.0 2.1 2.2 2.3 McPherson exposure(ms) 46 80 intervals(ms) 50 100 140 (b) Vt (km/s) 105 70 Conventional (1.70 s) Two-grating (1.75 s) 35 0 1.7 1.8 1.9 2.0 2.1 2.2 2.3 Major radius (m) FIG. 6.(a) The ion temperature profiles and (b) toroidal rotation velocity measured with both spectrometers for the KSTAR plasma shot number of 4364are compared. ITER CXRS optical fiber bundle the viewing lines diagnostic neutral beam spectrometers The Charge Exchange Recombination Spectroscopy (CXRS) system in an upper port plug for ITER. Figure from http://www.rijnhuizen.nl/annual_report/2007/02_the_research_at_rijnhuizen/2_2.html What’s Next? JT-60U Number of channels Spatial resolution toroidal : 23 toroidal : 5 cm Time resolution 16.7 ms poloidal : 36 poloidal : 0.8/1.5 cm K-STAR Number of channels The more, the better Time resolution 16.7 ms 1. 2. 3. 4. target 128 channels 20 ms Increase S/N by a factor of 3 or greater. Needs a CCD detector at Ajou. Design multilayer spectrometer systems. A few researchers.(Grads, Post doc.) 올해도 복스러운 해가 되기를 기원합니다 [Spectroscopic principle for CXRS] Neutral atom (H0) and impurity ion (Aq+) undergo a charge transfer that leaves the product ion in an excited state. H0 + Aq+ → H+ + [A(q-1)+]* Aq+ = C6+. carbon is one of intrinsic impurities and they are fully stripped throughout the plasma volume. Emissions are excited at wavelengths long enough for making accurate Doppler broadening and shift measurements. [Diagnostic Method] One of heating beams NB #14 is used for this measurement (see figures). Due to the above reaction, carbon ions near the neutral beam emit green light (529.2 nm at n=8-7 transition). Doppler broadening (→ temperature), Doppler shift (→ rotation velocity) and its area (→ impurity density). According to the ionization balance, there are C5+ ions in the edge region, which can emit at the same transition due to direct excitation by electrons (not by neutral beams). Therefore it is important to separate the spectrum by beam excitation from that by electron excitation. In order for this, CXRS system in JT-60U has an exclusive optics for the background spectrum. From Y. Koide, A. Sakasai, Y. Sakamoto, H. Kubo and T. Sugie, Rev. Sci. Instrum. 72, 119 (2001)