ASIPP EAST PF Coils Quench Protection Design of EAST Superconducting Tokamak Oct. 5, 2005 PF power supply team Institute of Plasma Physics,Chinese Academy of Sciences Hefei Anhui 230031 P.R.China ASIPP PF Coil Distribution The whole EAST PF magnet system consists of 14 coils, among them PF1 to PF6 are the CS coils, PF7 to PF10 are the diverter coils, and PF11 to PF14 are the PF big coils. They located symmetrically around the equatorial plane ASIPP PF Coil current in EAST operation I (KA) t (s) ASIPP The connection between PF coils and PFPS PS1 PS3 PS5 1# 3# 5# 7# 2# 4# 6# 8# PS2 PS4 PS6 PS7 PS8 PS9 PS11 9# 11# 13# 10# 12# 14# PS10 PS12 The PF system consists of 14 upper and lower SC coils around the plasma in the EAST tokamak, due to the series connection in diverter, 12 set of PFPS is essential. ASIPP Parameter for PF Magnet and Plasma Operation Nominal cycle period PF magnetization PF dwell time to keep magnetization Plasma initiation Plasma current ramp up Maximum plasma flat top Plasma current ramp down 2800 s 20 s 20 s 0.06 s 4s 1000 s 4s Tab. 1 EAST PF magnet parameters ASIPP PF Coil Parameters and Requirements Rated current Excited time Voltage (terminal to terminal) Voltage (magnet to ground) Limited heat condition Quench protection delay Self inductance Mutual inductance Storage energy in operation 15kA 20s 10000V 10000V 5.1108 A2s 1s 17.6~129.5mH 0.33~ 21.6mH 42MJ (max. 140MJ) ASIPP The power supply circuit of EAST PF coil F D ASIPP The requirements of quench protection ★ to discharge the magnets in such a way that is less than a prescribed limit under all conditions; ★ to limit the maximum instantaneous voltages imposed on the magnet (terminal to terminal, and terminal to ground); ★ to ensure successful discharge with a prescribed reliability for a given number of events over the design lifetime. ASIPP QP Feature for PF Coil ★ Frequent switching off. the high current rate, and plasma disruption in operation, The PF coil has possibly more quench, ★ strong coupling. The 12 pairs of coil have strong decoupling in each other, in QP the coil energy dissipation will be different from single coil. ★ Positive and negative current. in PF coil,it is important for QP design to use artificial current zero technology ★High power in input power supply. In PF magnet system, the primary power supply usually is quite high voltage, therefore it is necessary to suppress the input power supply in QP ASIPP PF Coil Storage Energy ASIPP PF Coil Storage Energy for Each energy ASIPP 不同运行方式下各线圈最大储能 (MJ) 托卡马克运 1,2 行方式\线圈 号 大拉长运行 3.8 3, 4 5, 6 7,8 9,10 4.3 3.4 2.4 12.1 3.0 大截面运行 3.8 4.3 3.4 0.73 3.5 3.9 1.4 大体积运行 3.8 4.3 3.4 1.75 9.1 5.5 1.03 最大能量 3.8 4.3 3.4 2.4 11,12 12.1 5.5 13,14 2.6 2.6 ASIPP QP System configuration CU1 CU2 D F 2 2 P DCCT The QP consists of bypass, DCCB, PB, fuse, resistor ASIPP QP Operation Scenario ★ Bypass primary PS. Upon command, the quench protection system will suppress the power supply, close the bypass CU3. ★ Open DCCB. open the DCCB1, after 100ms, and open DCB2. ★ Open PB. If the current detected by sensor DCCT after 200ms is not zero, the pyrobreaker PB will open. ★ Fuse melt, and Energy is dissipated in R . The current flowing through the magnet then follows the circuit through CU3, R and L, and the majority of the energy is deposited in R. ASIPP DC Current Breaker Rated voltage 1.5kV Rated current 15kA Max. breaking current 50kA Max. breaking voltage 3.0kV Closing time 110ms Switching time 30ms Operation numbers 104 times Weight 210kg ASIPP Current and voltage curve for DCCB test B– breaker current ; C– arc voltage ASIPP Backup Breaker--PB Rated current 20kA Max. breaking voltage 2.0kV Max. voltage 10kV Breaking time 100µs weight 110kg ASIPP Discharge Resister and Fuse The QP in each power supply d [i ] will work during the quench of [ L] [ R ][i ] 0 dt any PF coil. Therefore the PF QP system consists of 12 R-L [i] |t 0 [i0 ] branches that have magnetic 1 coupling, the total maximum [i0 ][ L][i0 ]T E max energy Emax stored in all coils 2 should be dissipated in these 2 i j dt Am (j 1, 2, ......,12) resistor R of each QP. In R design it is necessary to consider i j R j um (j 1 , 2, ........, 12 ) whole energy transfer and max. energy storage in each PF coil and different operation time ASIPP Fuse Current 400A 1000A Melting time Not melt 850s 2000A 80s 5000A 0.8s 15000A 0.01s Pay attention: ★ at high current, melt rapidly ★ at low current, melt longer ★ shunt current from parallel switch ★ Suitable fuse parameter match with SC magnet heat condition. ★ two diodes in opposite parallel are in series with fuse ASIPP Coil Current in Quench protection 5s /elongation ASIPP Coil energy in Quench protection 5s /elongation ASIPP I2t in Quench protection 5s /elongation ASIPP quench signal Control Unit for QP software controller hardware controller QP controllers consist of two parts: one is hardware controller realized by electronic circuit and relay; others is software controller realized by realtime operation system and industrial computers. CU1 or CU2 inveres delay20ms trigger CU3 DCCB1 switch off HVBC switch off delay80ms delay 80ms delay 100ms Up commands … DCCB2 switch off delay 200ms PB switch off & DCCT>0 ASIPP Parts of PF power supply equipment (7) ASIPP The end Thanks