* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download PowerPoint 프레젠테이션
Survey
Document related concepts
Public address system wikipedia , lookup
PID controller wikipedia , lookup
Electric motor wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Electric machine wikipedia , lookup
Power electronics wikipedia , lookup
Wassim Michael Haddad wikipedia , lookup
Stepper motor wikipedia , lookup
Induction motor wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Rectiverter wikipedia , lookup
Distributed control system wikipedia , lookup
Control theory wikipedia , lookup
Resilient control systems wikipedia , lookup
Control system wikipedia , lookup
Power inverter wikipedia , lookup
Transcript
INVERTER Table of Contents 1. Loom (textile) control system -----------------2. Loom traverse operation -----------------3. Warper (textile) control -----------------4. Building air-conditioning system using 485 -----------------communication 5. Trans parking system -----------------6. Cooling tower system -----------------7. Hoist driving system -----------------8. Socks manufacturing system -----------------9. Spray system for humidity control of textile -----------------factory 10. Slitting Machine -----------------11. Subway air-conditioning system -----------------12. Apartment water supply system -----------------13. Elevator driving system -----------------14. Aeration tank motor driving -----------------15. Compressor test system -----------------16. Fueling pump driving system -----------------17. Printing machine main motor system -----------------18. Running machine driving system -----------------19. Extruder screw driving system -----------------20. Steel plate line speed control system -----------------21. Coiler driving system -----------------22. Fiber coating system -----------------23. Laboratory air-conditioning system -----------------24. Energy saving case using inverter ------------------ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Appendix Loom (textile) control system 1.Introduction 3.Main function -Driving of yarn drum of loom (textile machine) should be controlled in line with main motor. Because the conventional system uses reduction gear, gearing ratio should be changed if the product type is altered. Therefore, we decided to control tension using inverter. -Field : Textile/loom -Type : iS5 2.System construction -Linkage control: Speed of main motor that releases the spool should be controlled in line with line speed of the drum. ⇒Rpm of main motor (for spool driving) is used as feedback for main speed control. -PID control: Feedback tension control 4.Others Spool 3-phase A/C Tension sensor M1 SV iS5 M3 M2 M4 Slave INV V 1 V 2 Fixed bar P/V V 1 5 G Main speed, M Pulse/voltage converter Textile manufacturer M2 P/V Mai n spe ed, M Drum Tension maintaining bar Final product 5 G Master INV Motor speed encoder M1 V 2 Tension sensor P/V Pulse/current converter Motor speed encoder 1/23 LG Industrial Systems Loom traverse operation 1. Introduction 3. Main function - When winding yarns, it is necessary to guide the yarns with traverse. - By traverse operation, the drum’s rpm is altered periodically, so that the yarns do not cluster locally (ribbon effect) or cut off. - Field: Textile machine/loom - Type: SV-iS5 - Traverse operation is performed using traverse function of APP Group, which is characteristic of iS5 - Conventionally, traverse operation was performed using inverter’s up-down operation and FDT function. However, it required additional volume and contact points. 4. Others Parameter DRV-1 DRV-2 DRV-4 I/0-12 I/O-13 I/O-40 I/O-41 I/O-42 I/O-43 I/O-44 2. Process & system construction Lint Roving machine Side view Spinning machine Winder Front view Cheese Cheese Functions Acc. time Dec. time Freq mode P1 define P2 define FM mode FM adjust FDT freq FDT band Aux mode Drum Drum Guide groove where yarns are wound Fixed guide Motor Clutch (0.4kW) yarn Clutch controlle r Winder Inverte control r ler (15kW) Parameters for iS5 traverse function 2/23 Setup 8s 12s Keypad-1 UP DOWN Freqency 78% 51Hz 8Hz FDT-5 Parameters for performing traverse operation through external sequence Parameter Functions DRV-1 Acc. time DRV-2 Dec. time DRV-4 Freq mode I/O-40 FM mode I/O-41 FM adjust APP-01 App mode APP-02 Trv. Amp APP-03 Trv. Scr APP-04 Trv Acc Time APP-05 Trv Dec Time APP-06 Trv Off Hi APP-07 Trv Off Lo Setup 8s 12s Keypad-1 Freqency 78% Traverse 7.8% 0% 1.1s 1.6s 0% 0% LG Industrial Systems Warper (textile) control 1.Introduction 3.Main function - Winds several strands of yarns in a plane. The inverter controls winding power and tension power. - Field: Textile/warper - Type: SV150iV-4 - Motor spec: 15㎾,440V.60㎐ -Winder: Winds aligned yarns -Bridle Roll: Applies tension to yarns -Comb-shaped structure: Aligns yarns uniformly 4.Others -In the system construction diagram, the threads consist of more than hundreds (300~600) of yarns. Yarns released from the threads are aligned by the comb-shaped structure and tension is applied to them while they pass the bridle roll. Then, they are wound by the winder after passing the second comb-shaped structure . 2.System construction Yarn spacing maintaining device Winder 5.Operation method -The bridle roll controls back tension with vector inverter. The winder is controlled by “PI” using iS3. Threads Bridle roll for maintaining tension 3/23 LG Industrial Systems Building air-conditioning system using 485 communication 1. Introduction 4. System construction - Introduces inverter using ESCO system in order to save energy consumption. - Field: Building air-conditioning/communication - Type: SV-iS5, iH, RS485 option card 10EA 7EA 13EA 11EA 2. Process construction Flow sensor INV N.C RF Speed control using RS485 communication RA Communication between inverters and various thermometers are controlled by the master controller. Tempera ture sensor SF CC Signal conversion is performed by one “System Base” 485 converter and three “RealSYS” 485converters. INV Speed control using RS485 5. Others Control Room - All 49 inverters are controlled by main control PC in Control Room using RS485 communication. - The inverters are allotted in groups considering communication overload and distance. - Because the user wants constant setup frequency regardless of power on/off,nonvolatile frequency in keypad command region, instead of common region frequency. 3. Main function - The inverter controls air conditioning according to temperature and number of customers, by the command of Control Room. - The supply is turned on, and the flow sensor detects air flow. 4/23 LG Industrial Systems Trans parking system 1. Introduction 3. Main function - If the car enters the parking area, it is lifted and placed to its parking position. Because a lot of cars can be parked in small area, this system is suitable for officetels or toll parking lots. - There are upper lifting (end lifting & intermediate lifting) and direct lifting modes according to the position of entrance. - Field: Parking Building - Type : iS5 - Brake opening signal should be output after identifying inverter output. The brake opening signal is generated after identifying operation (or frequency detection) signal in order to prevent falling of cars during inverter breakdown. ON ON Brake opening ON ON Fast Lifting 2. Process construction Slow Descendi ng Operation RX-ON ON FX RUN Slow Slow Slow Fast Passage - “Dwell” and “DC braking” during startup, and “DC braking” during stoppage help braking. Inv1 Ground level B1 Rotation M4 B3 M5 PLC M1 M3 B2 Inv2 4. Others M2 - Sufficient flux buildup time is required, because the motor may not be driven if the lifting acceleration time is too fast. - Stall prevention function should not be used when lifting cars. If the stall prevention is activated, the car can fall to the ground accidentally. M1 : Main lift M2 : Sub-lift M3,4,5 : For sliding 5/23 LG Industrial Systems Cooling tower system 1.Introduction 3.System construction -Cooling tower is used to cool down circulation water of chemical process. Because the cooling method is air-cooling, fan is required. The fan is driven by motor. -Conventionally, cooling of circulation water was done in On/OFF mode. However, we introduced speed control by inverter for precise control and energy saving. -Field: Fan/cooling tower -Type: iH Cooling tower Fan Motor Cooling water 2.Process construction Temperature sensing Temperature sensor INV PID controller PID V! 4.Main function <PID control> Temperature sensor -Frequency jump: Generally, the cooling tower has two or three resonance points within 0~60㎐. Therefore, operation may happen at resonance points if inverter is used for speed control. In this case, shafts that link motor bearing or motor with fan may be damaged. ⇒When applying frequency jump function, precise resonance points should be identified. For this purpose, speed is gradually altered during installation. Display V! variable resistor <Manual control> 6/23 LG Industrial Systems Hoist driving system 1. Introduction 3. Main function - A system for driving hoist, which is used for repairing lighting towers of baseball park. No precise control is required, but it is required to improve riding comfort. - Field: Hoist/lift - Type: inverter(SV-IS5) 2. Process construction 1) Speed control by voltage 2) Inverter run output is used for brake signal 3) Lifting/descent signal is controlled by the rider with lever. 4. Others Lighting tower 1) Dynamic Braking resistor is used to prevent release during deceleration. 2) Acceleration/deceleration time is determined by stop signal and stop position from test operation. DC brake is used to improve riding comfort during brake. Rack & pinion 3) Brake opening signal should be generated by accepting inverter run signal because signal delay or signal error may happen, and it is recommended to equip additional protection equipments such as governor in preparation for inverter error. ※ Brake operation diagram ~ Brake AXA, AXC Run signals 7/23 M/C LG Industrial Systems Socks manufacturing system 1. Introduction 3. Main function - LG inverter used for main driving source of socks manufacturing machine - Field: Socks manufacturing machine - Type: Inverter (SV-IG5) 1) Inverter - Forward driving startup (FX-CM) - JOG function - Speed control by keypad - Torque increase by manual torque boost function 2. System construction Spool 4. Others - Production speed can be regulated by controlling motor speed with inverter Socks manufacturing - Because JOG operation is possible, tangled yarns can be disentangled using JOG frequency. - Noise is reduced by inverter operation. - Machine handling becomes easy because machine operating Driving force transfer Inverter Final product (socks) part and inverter can be connected easily. Motor 8/23 LG Industrial Systems Spray system for humidity control of textile factory 1. Introduction 3. Main function - Humidity control of textile factory is important with regard to product quality. - The humidity control is performed by spraying moisture in room between air path. Generally, this spraying is controlled by valve, but if inverter is used, there will be advantage in control efficiency and energy saving. - Field: Pump - Type: SV-iH - Because the installed valve control system is replaced by motor speed control system, all that is required is matching valve control amount and speed control output. No additional function is required. 2. Process construction 4. Others Factory room - If there arises current non-equilibrium at input, this is due to factory electricity supply. It can be solved by adding reactors. sens or Humidity feedback Speed control Addition al controll er 9/23 LG Industrial Systems Slitting Machine 1. Introduction 3. Main function - Slits material of sanitary napkin for women (width: 1 m) in 8 strands and rewinds it. - Field: Linked controller/unwinder, slitting, rewinder, pinch - Type Unwinder: 037iV-2 1EA Slitting bridle: 037iV-2 1EA Rewinder: 022iV-2 4EA Pinch machine: 037iS3-2 1EA - Maximum line speed is 200m/m, and 10V main speed control is input. - Unwinder: Because minimum diameter of roll is 100 and the gearing ratio is 30:46,40:132,30:24, i.e. 4.048:1, the maximum motor speed is (200/0.1π)(132/40)(46/30)(24/30)=2577rpm. Also, because maximum diameter of the initial material is 1500 , motor speed at the maximum line speed becomes (200/1.5π)(132/4046/30)(24/30)=172rpm. That is, 172 ~ 2577 rpm should be maintained at the maximum line speed. 2. Process Slitting machine Rewinder Looper - Slitting bridle: Because minimum diameter of roll is 114 and the gearing ratio is 24:44,21:44, i.e. 3.841:1, the maximum motor speed becomes (200/0.1π)(44/21)(44/24)=2145 rpm. Unwinder Pneumatic - Rewinder : Because minimum diameter of roll is 190 and the gearing ratio is 30:46,1:5, i.e. 7.667:1, the maximum motor speed becomes (200/0.1π)(46/30)(5/1)=2569rpm. And, at the maximum diameter of 1200, the motor speed becomes (200/1.2π)(46/30)(5/1)=407rpm. - The rewinder uses torque minor loop mode in iV winder version. V2 iV022-2 V1 Position Sensor V2 V2 - The unwinder uses iV winder version with variable external PI speed control. The looper position data is linked with front slitting bridle operation. iV037-2 iV037-2 V1 V1 Main Speed Control(0~10V) Main Controller 10/23 LG Industrial Systems Subway air-conditioning system 1. Introduction 3. Main function 1) inverter - LG inverter used for air conditioning of subway station - Field: Air conditioner - Type: Inverter (SV-iS5) - Forward driving startup (FX-CM) - Speed control by variable resistor (V1) - Communication control selection using PLC - One-touch control using PMU 2. System construction - Remotely/locally controllable 4. Others -에너지 절감 Air in Air out -설비 유지 보수 용이 -운전소음 감소 - Communication control using PLC and PMU is possible. -물탱크 제거에 따른 설치비용 감소 - System control can be performed in station office because remote/local transition is possible. Train 5. 기타 - Energy consumption is reduced because air supply/return can be controlled by season. In ve인 rt버 er - Installation, maintenance and repair are simple. 터 Exhaust blower Supply blower 11/23 LG Industrial Systems Apartment water supply system 1. Introduction 3. Main function 1) Inverter - LG inverter used for supplying water to apartment households - Field: Water supply pump for high-rise apartment - Type: Inverter(SV-iS5) - Forward driving startup (FX-CM) - Speed control by variable resistor(V1) - Control by communication 2. Process construction 2) PLC - Process PID control Apartment (12~18F) 4. Others 6 buildings / 860 households - PLC (Master-k80s) was used as main controller. Speed of 4 inverters was controlled by PID control. - Because the water volume is controlled in real time using inverter, the conventional water tank becomes unnecessary. Pressure gauge PLC 인 버 터 1 인 Inv2 인 버 터 3 인 Inv4 Inv1 Pump 1 Underground water tank Pump 2 Pump 3 Pump 4 Inv3 - Motor noise is reduced remarkably because motor speed is controlled by inverter. 버 터 2 - Remote water supply system control is possible using PMU (optional). 버 터 4 12/23 LG Industrial Systems Elevator driving system 1. Introduction 3. Main function 1) Height detection by inverter - LG vector inverter used for elevator control - Field: Elevator - Type: Inverter(SV-IV5L) 2) Acquires optimum speed pattern by calculating remaining distance 3) Position signal is transferred to main controller continuosly 4) Driving signal of electronic brake is directly controlled by inverter 2. Process construction Electronic brake 4. Others Motor Inverter 1) iV5-L or iV5 can be selected depending on requirements of main controller. Encoder 2) Because the inverter should send and receive specific signal with main controller, matching with the main controller is important.(iV5L Version) 3) Motor characteristic value is tuned without really driving the motor, by stop-type auto-tuning. Counter Weight 3Φ AC Car Sensor 13/23 LG Industrial Systems Aeration tank motor driving 1. Introduction 3.Main function -DO(dissolved Oxigen) of water is controlled for rapid reaction of pollutants and chemicals. -Inverter is used for speed control. -Inverter is used for precise control and energy saving. -Field: Blower/aeration tank -Type: SV075iH-4(75㎾) -Motor spec: 75㎾, 2-pole -PID control is used to precisely control water concentration. 4.Others 2.System construction -Although the blower is energy-saving load, energy consumption is not saved if aeration tank is the main load. ⇒Pressure is applied to the blower of aeration tank because it is positioned in water. Therefore, a large torque is required to overcome the pressure and expel air bubble. Here, the water pressure acts as damper. Blower Damper control and aeration tank characteristics Air bubble Inverter Water concentration detection PID control Power (㎾) General energy-saving characteristic curve Load (blow or flow volume) <Load amount vs. Power consumption> 14/23 LG Industrial Systems Compressor test system 1. Introduction 3. Main function 1) Inverter - LG inverter used for compressor test - Field: Screw-type compressor - Type: Inverter(SV-IH) - Forward driving startup (FX-CM) - Speed control by keypad - Overload trip - Overheat prevention 2. System construction 4. Others Inverter Screw-type compressor - Because frequency can be easily altered with inverter, test can be carried out for any country. - Because the inverter provides data such as power consumption, output voltage and output current, additional equipment is unnecessary. Connected for compressor test Breaker 3-phase output line 3Φ AC 15/23 LG Industrial Systems Fueling pump driving system 1. Introduction 3.Main function -Fueling pump for supplying oil to airplane. Oil pressure is maintained by inverter depending on load change. -Field: Pump -Type: SV-iH -Except for ordinary operation (60㎐) to maintain constant pressure, additional load (fueling amount) is controlled by inverter in order -PID control : 4~20㎃ of pressure signal is transferred to DCS, and DCS sends PID output for inverter control. 2.System construction 4.Others DCS Control System 4~20mA input 4~20mA P -Because the motor was for medium-voltage (6,600V), UP/DOWN transformer was used to control low voltage inverter (440V). ⇒Inverter input was decreased from 6,600V to 440V. Then, inverter output was increased from 440V to 6,600V because the motor was for 3300V. ⇒Heat resistance is important when selecting the UP/DOWUN transformer, because heat is generated. Pressure signal transfer P P P 16/23 LG Industrial Systems Printing machine main motor driving 1. Introduction 3.Main function -Prints two colors after unwinding paper roll, and then rewinds it. -Field: Individual machine (printing machine) -Inverter: SV037iV5-4 (3.7㎾) -Motor spec: 3.7㎾ (Encoder equipped to general motor: Metronics 1,000Pulse) -ASR (Automatic speed regulator) P,I gain control ⇒P gain: 40% I gain: 400㎳ 2.System construction 4.Others Tension controller 2-Color printing -The rpm variation should be within 1rpm for printing accuracy. ⇒If variation becomes large, printing position may not coincide in 1-color printing and 2-color printing. Connected by gear 1-Color printing 0~10V Variable resistor LG vector inverter E Motor Encoder feedback 17/23 LG Industrial Systems Running machine driving system 1. Introduction 3. Main function - LG inverter used for controller of running machine driving motor - Field: Running machine - Type: Inverter (SV-IC5) 1) Inverter - Forward driving startup (FX-CM) - Speed change by Up/Down operation - Sensorless vector operation 2. Process construction - Motor overheat prevention - Overload trip - Control by communication 4. Others Motor 1Φ AC Inverter - Strong torque characteristics at low speed by sensorless vector - Smooth acceleration/deceleration and reduced noise - Product stability increased by motor overheat prevention and inverter overload prevention - Communication with running machine specific controller is possible 18/23 LG Industrial Systems Extruder screw driving system 1. Introduction 3. Main function 1) Inverter - LG inverter used for extruder screw driving - Field: Extruder screw - Type: Inverter (SV-IH) - Forward driving startup (FX-CM) - Speed control by variable resistor (V1) - Motor overheat prevention - Overload trip 2. Process construction Raw material 4. Others - Productivity can be increased because extruder screw Inverter speed can be easily controlled by variable resistor (V1). - The screw speed can be controlled in real time depending on the temperature of extruder cylinder. - If the motor is overloaded or overheated because of poor extrusion, the self-protection function protects the motor and inverter without additional equipment. Screw - Because the motor speed is controlled by frequency, the wider and more precise control is possible compared with conventional step control. - Motor noise is reduced. Motor 19/23 LG Industrial Systems Steel plate line speed control system 1. Introduction 3. Main function - Forward driving startup (FX-CM) - LG vector inverter used in steel plate production line - Field: Individual machine (roller) - Type: SV-iV - Up/Down operation - Jog frequency operation - Use DB resistor - Motor overheat prevention 2. System construction - Overload trip 3ΦAC Steel plate drum Leveler LG vector invert er 4. Others Cutting roll Product (steel plate) - Leveler’s main role is to remove residual stress. - Product size can be controlled precisely by leveler line speed control using inverter. - UP-Down operation and Jog function for ease operation. - Vector was used to precisely control line speed in order to obtain precise dimension of final product. - AC reactance was applied at input line for power-factor improvement and input circuit protection. Cutter Steel plate 20/23 LG Industrial Systems Coiler driving system 1. Introduction 3.Main function -The conventional winding motor requires large current for startup and is disadvantageous in productivity. -Inverter is used to reduce startup current and improve productivity. -Load: Coiler -Inverter: SV132iH-4 (132㎾) -Motor:110㎾ (Modified winding motor) -During startup: Acceleration time should be selected so that the normal speed can be attained within 1min for general 150% load. -During stoppage: Because the rotational inertia is large, free run stoppage and machine brake are used. 2.System construction 4.Others Drum(24inch*6,16inch*9,12inch*1) -Because winding motor is used directly to inverter, internal resistance of the motor was removed. ⇒During wire connection, overheat may damage the wire. Capstan Decelerator Twister Drum -Twister: Twists 16 strands of wire released from each drum. -Capstan: Applies tension to maintain the twisted state. 21/23 LG Industrial Systems