* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Document
Survey
Document related concepts
Electrical engineering wikipedia , lookup
History of electric power transmission wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power electronics wikipedia , lookup
Voltage regulator wikipedia , lookup
Current source wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Surge protector wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electronic engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Power MOSFET wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Transcript
Technology & Engineering Division DATA ACQUISITION FOR PRE-OPERATIONAL TESTING OF BNL-E951 15T PUSLED MAGNET Chen-yu Gung Mercury Target Collaboration Meeting MIT Plasma Science and Fusion Center October 17 – 19, 2005 DAQ for BNL 15 T Pulsed Magnet 1 Technology & Engineering Division Instrumentation and Signal Level Instrumentation Name Number of Signals Signal Level Power Supply 2 (Vmagnet & Vshunt resistor) 0 – 10 V AMI LN level sensor 2 0 – 10 V CERNOX 11 Varies with temperature Discrete level sensor diode 10 Unknown Others, such as TC’s, Hall probe, etc. TBD TBD DAQ for BNL 15 T Pulsed Magnet 2 Technology & Engineering Division CRYOGENLEVEL LEVEL CRYOGEN CONTROLLER CONTROLLER V_ps CH01 I_ps CH02 L01 CH03 L02 CH04 T01 CH05 CH06 . . T11 D01 D02 . . D09 PULSED MAGNET D10 . OTHERS . . Txx: CERNOX; Dxx: DIODE / DISCRETE LEVEL SENSOR; Lxx: LN LEVEL SENSOR (CONTINUOUS); DAQ for BNL 15 T Pulsed Magnet VOLTAGE DIVIDERS T02 . . T10 ISOLATION AMPLIFIERS PULSED MAGNET POWER SUPPLY CH14 CH15 CH16 CH17 . DAQ DAQCARD CARD NB-MIO-16XL-18 NB-MIO-16XL-18 SIGNALS AND DATA ACQUISITION FOR PULSED MAGNET TEST MAC / LABVIEW . CH24 CH25 CH26 . . CH32 3 Technology & Engineering Division Data Acquisition System Use 2 National Instrument NB-MIO-16XL-18 in one Macintosh computer. DA is programmed in Labview. — Thing to do – modify existing program. Precision at 16 bit for bipolar DA between ± 10 V: ~ 0.3 mV. Maximum (damaging) input voltage: ± 35 V. Max. sampling rate for single channel DA: 55 Ksamples/sec. Max. sampling rate for multi-channel DA: 20 Ksamples/sec. DAQ for BNL 15 T Pulsed Magnet 4 Technology & Engineering Division CERNOX Temperature Sensor ~ 400 Ohm ~ 40 Ohm Ref: Courts, S.S and Swinehart, P.R., ‘Stability of Cernox Resistance Temperature Sensors’, Adv. in Cryogenic Eng., Vol. 45, 2000. Typical resistances of CERNOX are between 40 Ohm and 400 Ohm at respective temperatures of 120 K and 80K. The sensor voltage signals are between 0.4 V and 4 V if an excitation of 10 mA is used. DAQ for BNL 15 T Pulsed Magnet 5 Technology & Engineering Division Excitation Source for CERNOX Lake Shore Model 120CS Current Source Output Current 1 A to 100 mA Accuracy 0.1% on fixed ranges Stability Better than ± 0.01% Compliance Voltage 11 Volts up to 50 mA • Each current source will be used to drive 4-5 CERNOX’s connected in series with an excitation current set at 10 mA. Connections of the current leads will be made outside the magnet vessel. • Four lead measurement will be used. The voltage leads will be tapped to the current leads outside the magnet vessel. • The voltage drop along the lead wires needs be corrected. • The same type of current source will be used to drive the discrete LN level sensor diodes. Connection: TBD. DAQ for BNL 15 T Pulsed Magnet 6 Technology & Engineering Division Data Acquisition During Cool-down and After Pulsing During cool-down and before pulsing the magnet, including purging out LN, record — — — LN level Temperature DAQ sampling interval: 2 minutes (tentative) After pulsing the magnet, record — — Temperature DAQ sampling interval: 30 seconds (tentative) DAQ for BNL 15 T Pulsed Magnet 7 Technology & Engineering Division Data Acquisition During a Pulse (Optional) Will attempt to record the power supply voltage and current, and the temperature variation during a pulse. But, it is dictated by the inductive voltage picked up by the DAQ system (noise and voltage limit). Need ~ 13 channels.; zero LN level signals will not be recorded. A typical pulse duration is ~ 15 seconds. The sampling interval can be set to 5 ms. DAQ for BNL 15 T Pulsed Magnet 8 Technology & Engineering Division Summary Record temperature and LN level signals with existing equipment before and after pulsing the magnet is straightforward. — TBD: Excitation and signal level of discrete level sensor diode. Recording temperature signal during a pulse (optional) is dictated by the inductive voltages picked up by the DAQ. DAQ for BNL 15 T Pulsed Magnet 9