* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Example - s3.amazonaws.com
Audio power wikipedia , lookup
Wireless power transfer wikipedia , lookup
Ground (electricity) wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Mathematics of radio engineering wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Power inverter wikipedia , lookup
Current source wikipedia , lookup
Fault tolerance wikipedia , lookup
Power factor wikipedia , lookup
Flexible electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Two-port network wikipedia , lookup
Electric power system wikipedia , lookup
Circuit breaker wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Buck converter wikipedia , lookup
Electrification wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Integrated circuit wikipedia , lookup
Earthing system wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mains electricity wikipedia , lookup
Power engineering wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Alternating current wikipedia , lookup
EGR 272 – Circuit Theory II Lecture #12 Read: Chapter 11 in Electric Circuits, 6th Edition by Nilsson Generator and line impedances Sometimes impedances in the generator and the lines are considered in 3-phase circuits. This will result in power losses in each line and in reduced load voltages. Example: The 4-wire Y-Y system below has a balanced generator with 720 V RMS and an acb phase sequence. Determine IaA, Van, VAN, and the power loss in each line. a + 1 A + j2 + j3 2 5 + j10 n N - - + + j10 b + 1 B + j2 1 Generator j2 + j3 2 c + j10 5 C + 2 j3 Line + 5 Load 1 Lecture #12 EGR 272 – Circuit Theory II - system Recall for a generator that VL = Vp. So analyzing the - system is similar to analyzing the Y- system except that the line voltages are more easily found. Example: Determine the three line currents for a - system that has a balanced generator with 240 V RMS and a negative phase sequence. The loads are as follows: ZAB = 3+j4, ZBC = 3-j4, and ZCA = 2+j2. 2 Lecture #12 EGR 272 – Circuit Theory II Load with line impedances Including line impedances with a load makes the analysis more difficult. A good way to approach the problem is to use a -Y conversion to change the load into a Y load. Delta-to-Wye (-Y) and Wye-to-Delta (Y-) Transformations In EGR 271 -Y and Y- transformations were used with resistive circuits. These transformations can also be used with circuits consisting of AC impedances. Recall that the transformation equations are derived based on a specific labeling of the impedances, so the equations below are somewhat useless without the corresponding figures. 3 EGR 272 – Circuit Theory II Lecture #12 Delta-to-Wye (-Y) and Wye-to-Delta (Y-) Transformations a b a Z1 b Zc Z2 Zb Za Z3 c Wye Circuit Y - Conversion Equations : c Delta Circuit - Y Conversion Equations : Za Z1 Z 2 Z 2 Z 3 Z3 Z1 Z1 Z1 Zb Z c Za Z b Zc Zb Z1 Z 2 Z 2 Z 3 Z3 Z1 Z2 Z2 Zc Z a Za Z b Zc Zc Z1 Z 2 Z 2 Z 3 Z3 Z1 Z3 Z3 Za Z b Za Z b Zc Special case: If the load is balanced, these equations reduce to: Z 3 ZY (balanced load) ZY Z (balanced load) 3 4 Lecture #12 EGR 272 – Circuit Theory II Example: Determine the three line currents in a 3 Y- circuit described as follows: • The Y generator is balanced with an abc phase sequence and Van = 480 V • Each of the 3 lines (between source and load) has an impedance of 2 + j4 ohms • The load is balanced where each of the three loads have an impedance of 60 + j90 ohms 5 Lecture #12 EGR 272 – Circuit Theory II Power Calculations in 3 Circuits Total power delivered = (power delivered to each phase) Or PTotal P where P V I cos( ) and V , I , and are the voltage, current, and phase angle for each phase and is the phase angle of the impedance (or V - I ) Note: Power can be calculated, as it would be for any AC circuit. For example, total power could be found by finding the power to the resistive portion to each load. 6 Lecture #12 EGR 272 – Circuit Theory II Example: Find the total power delivered to the Y-Y circuit analyzed last class (4-wire Y-Y system has a balanced generator with Van = 480 V and a positive phase sequence with ZAN = ZBN = 2 + j2 and ZCN = 2 - j2). 7 Lecture #12 EGR 272 – Circuit Theory II Example: Find the total power delivered to the Y-Y circuit analyzed last class (balanced system with Van = 240 V, a negative phase sequence, and with impedances as follows: ZAB = 6 + j8, ZBCN = 6 – j8, and ZCA = 6). 8 Lecture #12 EGR 272 – Circuit Theory II Measuring Power with Wattmeters: A wattmeter is a piece of equipment that measures average power, P, in watts. A wattmeter has connections for both current and voltage, as shown below on the left (Electric Circuits, 9th Ed., by Nilsson). Note that the positive side of the current coil and the positive side of the voltage coil are labeled + or +. The wattmeter shown below on the right shows how a wattmeter might be connected in a circuit. a IaA + + W1 + + Van Van - n 9 EGR 272 – Circuit Theory II Lecture #12 Wattmeter reading: A wattmete r reads real (or average) power, P, in watts (W). I + + W1 + V - It reads the real part of the complex power, S V I * where V and I are the voltage and current at the wattmeter terminals . so P1 W1 Re V I * or P1 W1 V I cos( ), where is the phase difference between V and I The 2-wattmeter method and the 3-wattmeter method: Two common methods for measuring power are the 2-wattmeter method and the 3-wattmeter method. In the 3-wattmeter method, all negative voltage connection on each of the wattmeters is common (typically on the neutral line). In the 2wattmeter method, the positive voltage terminal on two wattmeters is connected to any two of the lines and both negative terminals are connected to the third line. It can be proven that total power is the sum of the wattmeter readings in either method. 10 Both methods are illustrated on the following page. EGR 272 – Circuit Theory II Lecture #12 The 3-wattmeter method: IaA a + + Van - A W1+ + Van Vcn - Vbn W2 + + + b ZCN ZBN Vbn IbB N - + + IcC W3 + c Vcn + + * * ZAN - - n W1 Re V an IaA W2 Re V bn I bB B C * W3 Re V cn IcC PT W1 W2 W3 The 2-wattmeter method: IaA a + + Van - A + Vac N Vbn - + + IbB b ZCN + WB + Vbc - I B * * bc bB PT WA WB ZBN + W Re V WA Re V ac I aA ZAN - n Vcn c WA+ B C 11 EGR 272 – Circuit Theory II Lecture #12 Example: Determine the reading for each wattmeter below and the total power absorbed by the load if the circuit has a balanced generator with Van = 480V, a positive phase sequence, and impedances ZAN = 6+j8, ZBN = 8+j6, and ZCN = 5-j5. IaA a + A + WA + Vac + n - Vcn N Vbn + + IbB b c ZAN Van ZBN ZCN + + WB + Vbc - B C 12