Download Advel PSUs - Indico

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Wireless power transfer wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Current source wikipedia , lookup

Power over Ethernet wikipedia , lookup

Stray voltage wikipedia , lookup

Power factor wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electrical substation wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Audio power wikipedia , lookup

Islanding wikipedia , lookup

Electric power system wikipedia , lookup

Electrification wikipedia , lookup

Rectifier wikipedia , lookup

History of electric power transmission wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Power engineering wikipedia , lookup

Opto-isolator wikipedia , lookup

Power electronics wikipedia , lookup

Buck converter wikipedia , lookup

Alternating current wikipedia , lookup

Mains electricity wikipedia , lookup

Power supply wikipedia , lookup

AC adapter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
Controls and Electrical Preferred
Technologies
Advel Power Supplies and ABB
Circuit Breakers
Steve Pavis PH-DT-DI CERN
Gas
Control
System
Steve Pavis PH-DT-DI CERN
Advel Power Supplies
Steve Pavis PH-DT-DI CERN
Technical Requirements (extract from our specification)
•
Preference is that overall power requirements for an individual system be
achieved within a single 19" rack mounting chassis. Where this is not
possible, e.g. for the larger systems, then two or more 19" rack mounting
chassis may be used provided their outputs can be connected together
whilst still maintaining current sharing.
•
The bidder should state “Comply” or “Doesn’t Comply” against the
following requirements for clarity in evaluating offers.
•
Housing : 19” 3U, 4U or 6U high chassis for Rack mounting
•
Hot Swappable/pluggable Power Supply modules with Input Voltage:
220VAC Input Frequency :50Hz, Output Voltage: 24VDC and 15VDC
versions (see table), arranged in an N+1 or Dual Redundant configuration
with Power Sharing.
•
Efficiency : >= 80%
•
Ripple & Noise (Acc. to IEC/EN 61204) : <= 50mV p-p
•
Output Hold up time : 15ms
•
Deviation due to dynamic load change (Transient Response) : for 60%
step load increase, output voltage must not deviate by more than 3V.
•
Front of Module LEDs for Power Supply Status
•
Power Fail Signal: Volt free contact to be provided (via terminals on the
rear of the chassis) for power fail indication of any power supply module.
•
AC input terminals and DC output terminals to be provided at the rear of
the chassis.
•
Operating Temperature: 0 - 55 degrees Celcius
•
CE Marked for compliance to EMC and Low Voltage Directives (Immunity
and Emission)
Advel PSUs
Steve Pavis PH-DT-DI CERN
In addition, the bidder should indicate the following in
the offer:
1
“In rush current" when turning on the power system (for both "no
load" and "full load" conditions)
2
Level of power factor correction (if provided)
3
MTBF for each power supply module
4
Method of power sharing e.g. "Active Current Sharing" (third
wire), or "Passive Current Sharing" (Droop regulation/Slope
Programming).
5
If current limiting is provided on the 24VDC/15VDC output,
please specify and indicate the level.
6
Height of the 19” rack mounting chassis which houses the power
modules.
Advel PSUs
Steve Pavis PH-DT-DI CERN
Responses To Cern
Specification
Advel PSUs
Steve Pavis PH-DT-DI CERN
Responses To Cern
Specification continued
Advel PSUs
Steve Pavis PH-DT-DI CERN
Advel PSUs
Steve Pavis PH-DT-DI CERN
LEDs indicate correct
current balancing and
temperature within good
operational limits
Any voltage !!
25W
250W
600W
50W
300W
750W
150W
350W
1000W
200W
500W
2000W
Output Voltage Adjust Fan Healthy LEDs
+/- 10% (in addition to
sense lines)
Advel PSUs
Steve Pavis PH-DT-DI CERN
Advel PSUs
Steve Pavis PH-DT-DI CERN
Advel PSUs
Steve Pavis PH-DT-DI CERN
PSU Circuit
Diagram
Steve Pavis PH-DT-DI CERN
ABB Busbar Mounted Circuit
Breakers
Steve Pavis PH-DT-DI CERN
AC Power Distribution
Miniature Circuit
Breakers Directly
Mounted On Busbars
(Complete assemby can
be done “on the bench”
to enable speedy
installation)
Pump Variable Frequency Drive
shielded from sensitive signals
Fieldbusses “Daisy
Chained” down the
back of the control
chassis
Rear View
Steve Pavis PH-DT-DI CERN
Touch Proof Pluggable System – load free MCBS can be snapped on and off
the bus bar assemly under live conditions without risk.
ABB Busbar
Mounted MCB
Solution
Steve Pavis PH-DT-DI CERN
Can be clipped under
live power conditions
Auxiliary
Contact
Busbar
Busbars rated
to 200A
Phase selection
ABB Busbar
Mounted MCB
Solution
Steve Pavis PH-DT-DI CERN
Various Motor
Starters available
Current measuring
modules with
LED indicators
ABB Busbar
Mounted MCB
Solution
Steve Pavis PH-DT-DI CERN
ABB Busbar
Mounted MCB
Solution
Steve Pavis PH-DT-DI CERN
ABB Busbar
Mounted MCB
Solution
Steve Pavis PH-DT-DI CERN
ABB Busbar
Mounted MCB
Solution
Steve Pavis PH-DT-DI CERN