* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 1 - hoytmonitor
Electric power system wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Smart meter wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Power over Ethernet wikipedia , lookup
Opto-isolator wikipedia , lookup
Sound level meter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Stage monitor system wikipedia , lookup
Power engineering wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
History of electric power transmission wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Peak programme meter wikipedia , lookup
Distribution management system wikipedia , lookup
WattDog WattView PanelDog Hoyt Monitor Technologies presents The Dog Meters 5/23/2017 1 WHAT IS A WATTDOG? ANSWER: An AC measuring meter with a deep level of intelligence that displays and records all parameters relevant to AC Power measurements A GRAPHICAL colored LCD with TOUCH SCREEN control Full Duplex Communication Ports Software for the creation of an Executive Summary Report Optional Software for on site configuration 5/23/2017 2 Display Information Wire Configuration Local Time and Date AC POWER Instantaneous Watts Active Lines 3:52 PM 02/11/11 1P3W V olts : 120V / Cumulative Power Approximate cost Approx. Active Rate for period measured 163.8 1.37 $0.12 Voltage per Phase WATTS KWh Cost Activ e Rate $0.085 De tail Gr aph Se tup About HOYT MONITOR TECHNOLOGIES 5/23/2017 3 More Display Information AC POWER 3:52 PM 02/11/11 1P3W V olts : 120V / 163.8 1.37 Toggle through installed screens $0.12 WATTS KWh Meter Set up and Memory details Cost Activ e Rate $0.085 De tail Setup Graph details 5/23/2017 Gr aph Se tup HOYT MONITOR TECHNOLOGIES About Configure Logging Time and Dates 4 SECONDARY DISPLAY OPTIONS AC POWER AC POWER 3:52 PM 02/11/11 3:52 PM 02/11/11 3P3W 3P3W 120V / AM PS L1 L2 L3 Detail 0.85 0.46 0.20 Graph KWh PF 1.53 0.96 0.83 0.95 0.04 0.96 Setup 120V / About HOYT MONITOR TECHNOLOGIES Amps L1 L2 14.6 1664 .95 L3 14.4 1659 .96 Cost A wide range of screens are available to the viewer AC POWER W 00 13 Cost De tail 00 13 HOYT MONITOR TECHNOLOGIES About 25 t $ 00 5: Se tup 2:56 PM 00 5: Graph 3.5 2.4 0.5 00 1: Start: Demand Pk W 00 1: 1.63 0.130 1.70 0.134 1.66 0.132 Active Rate $0.085 5/23/2017 WattDog will accommodate this requirement 3P3W 120V / De tail About Se tup Graph De tail HOYT MONITOR TECHNOLOGIES 3:52 PM 02/11/11 L1 L2 L3 PF .96 AC POWER KWh Watts 14.3 1647 Many times users want different parameters displayed Graph Se tup HOYT MONITOR TECHNOLOGIES A few of the choices available are being shown t About Use your imagination and create your own 5 Display Description / Advantages KWh / Phase This display shows: Amps / Phase PF / Phase Advantage: Any significant load unbalance is seen AC POWER 3:52 PM 02/11/11 Amperes per Phase 3P3W 120V / AMPS KWh PF L1 L2 L3 0.85 0.46 0.20 1.53 0.96 0.83 0.95 0.04 0.96 Detail Graph Setup HOYT MONITOR TECHNOLOGIES About KWh per Phase Advantage: Shows loading which can translate to cost Power Factor Advantage: See the PF of the load per phase A poor Power Factor will impact the overall cost 5/23/2017 6 Display Description KWh Cost per Phase AC POWER 3:52 PM 02/11/11 3P3W 120V / KWh L1 L2 L3 Cost 1.63 0.130 1.70 0.134 1.66 0.132 Active Rate $0.085 Start: Graph Se tup De tail Pk W 3.5 2.4 0.5 2:56 PM • This information is useful in scheduling a machine in a process • Seeing the energy per phase and the cost About HOYT MONITOR TECHNOLOGIES Any parameter can be displayed as an independent value on a separate screen 5/23/2017 Peak Watts • Load Anomalies can be seen leading to an investigation of a potential problem 7 Display Description Users sometimes prefer to see Graphic representations of certain parameters AC POWER W Demand 00 13 00 5: 00 1: 25 t Cost A Graph is an instant view of a series of measurements taken over a period of time $ 00 13 00 5: 00 1: De tail Graph Se tup HOYT MONITOR TECHNOLOGIES 5/23/2017 t About By including this facility within the meter, it allows a user to view parameters without opening a computer and searching a file 8 Sometimes Simplicity is all that is needed Wire Configuration Local Time and Date Active Lines AC POWER 1P3W 3:52 PM 02/11/11 120V / Accumulated KWh since start Voltage per Phase 1.37 KWh Time and Date logging started This screen is showing KWh only Star t: 4:00PM 03/29/11 De tail Se tup About HOYT MONITOR TECHNOLOGIES Star t Start Time and the Start Date is displayed. These parameters might be different for the local time and date Touch Screen can be Disabled to prevent access 9 5/23/2017 Sometimes, Simplicity still requires additional information Total KW per tariff period The Demand Period breakdown AC POWER Cost for each period 1P3W 3:52 PM 04/05/11 120V/ KW 5.37 10.57 Dem Per Peak Off Peak Cost $44.68 $1.46 Historical data is always valuable End 5:00 PM 4/11/11 De tail Se tup About These screens are user selected at time of configuration AC POWER Star t 3:52 PM 04/05/11 History HOYT MONITOR TECHNOLOGIES Ye ar 2010 2011 2012 De tail Total KWh 2.2M Wh 2.1M Wh 2.03M Wh Se tup About Cos t $9,333 $9,280 $8,930 Star t If not selected at initial configuration they can be added in the field with a firmware upgrade HOYT MONITOR TECHNOLOGIES 5/23/2017 10 Limited Fault Detection capability 1P3L Single Phase 3 Lines Note this image is labeled 1P 3L. This configuration allows the user to look at 3 branch circuits on the same phase. Using a DC Version of the meter and the HMT Multiplexer module the viewer can view multiple branch circuits using one meter Error indications The meter is pre-configured for the wiring requirements of the application If the meter detects a voltage on the applicable inputs then the lighted dots will appear Green If one line or multiple lines do not have a voltage present, the illuminated Dots will show as RED and flash 5/23/2017 11 Typical Panel installation CT’s can be Split Core of Solid Core types 3:52 PM 02/11/11 CT1 1P3W Volts: 120V/ 163.8 1.37 HMT CT2 HMT WATTS KW h Ac tiv e Rate $0.085 Graph Setup Main Breaker Neutral Bus ON Cost Off $0.12 Detail P2 Neutral P1 AC POWER The installer has a choice of using Split Core CT’s or Solid Core CT’s About G ROUND 15 15 15 15 15 A A A A A 15 A 5/23/2017 Revision 3 15 15 15 15 A A A A 15 15 15 15 A A A A Voltage Leads from phase to meter terminals. 15 15 15 15 15 15 A A A A A A HOYT MONITOR TECHNOLOGIES For higher accuracies use Solid Core CT’s 12 Making the Connections Ethernet P1 CT1 P2 P3 CT2 CT3 SD USB N P G AUX ACV 5/23/2017 Revision 3 WattDogs Rear Panel is labeled and color coded for easy installation Ethernet, USB, and SD Card ports are located on the Rear Panel 13 Review We have seen A meter set up as single display with multiple pieces of information A meter set up as a single display with 1 line of information A meter with the ability to have multiple screens available for a quick check of measured parameters The ability to inhibit screens at the meter site and view the measured parameters at a central location The ability to configure the meter to display any measured parameter The Choices are yours. 5/23/2017 14 SOFTWARE DO WE NEED IT ? Any measurement worth making is worth saving Recording this measured data is key to being able to manage or analyze the obtained results Equally important is the method used to store the measured results Just as important is the retrieval of the data and the ability to place it into a report format The instrument used for storing and reporting results is 5/23/2017 software 15 What is WattView Reporter WattView Reporter is the Utility Software supplied with each WattDog meter With the Reporter Software the user can: Setup Information on meter as to its configuration and location Setup Start Time and Start Date for a recording Setup Stop Time and Stop Date for a recording Setup Continuous recording (No stopping time or date) Generate A detailed report of the measured parameters Export Data to other data based files for analyzing or billing purposes View Data in text or graphic formats 5/23/2017 16 WattView Prepare to add a meter to the system library Identify each meters configuration Open to set logging criteria Open to select report writer Welcome to the Home Page. From here you can navigate through this easy to use program 5/23/2017 17 WattView Reporter Meter Inventory WattView shows: • The meters installed Installed Meters • The location of each Management Information Meter Inventory and Configuration Meters Locations • Configuration of each • Other pertinent information 5/23/2017 18 WattView Reporter Circuit Configuration Circuit Type Circuit usage WattView lists the configuration of the circuit and its location 5/23/2017 19 WattView Reporter Circuit Configure Select location for logging Set the logging interval WattView sets the logging time and location of the meter 5/23/2017 20 WattView Reporter Set Primary Current Set Primary Voltage Set PT Ratio Set CT ratio Setup phase voltage and current as well as PT and CT scaling ratios 5/23/2017 21 WattView Reporter Here we report the Name of the Job We set the logging Start Date We set the logging End Date The Peak and Off Peak Tariffs are installed We include Company and Contact Information 5/23/2017 22 WattView Reporter Reports The user can select a wide range of reports with detailed information on parameters chosen at setup 5/23/2017 23 Summary The Dog Meters (WattDog and PanelDog) are multi-functional products These meters can be configured to measure any physical parameter They are capable of being scaled to AC or DC value They offer a full array of communications They offer control signals They represent the next generation in metering devices Remember! The only limit this meter series has, is your imagination 5/23/2017 24 THE END We thank your for your attention. Questions? 23 Meter Street Penacook, NH 03303 5/23/2017 25