* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download applications of gps in power engineering
Power factor wikipedia , lookup
Stray voltage wikipedia , lookup
Standby power wikipedia , lookup
Power inverter wikipedia , lookup
Buck converter wikipedia , lookup
Control system wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Wireless power transfer wikipedia , lookup
Utility frequency wikipedia , lookup
Fault tolerance wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power over Ethernet wikipedia , lookup
Electric power system wikipedia , lookup
Rectiverter wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrical substation wikipedia , lookup
Power electronics wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mains electricity wikipedia , lookup
APPLICATIONS OF GPS IN POWER ENGINEERING What is GPS? GPS or Global Positioning Systems is a highly sophisticated navigation system developed by the United States Department of Defense. This system utilizes satellite technology with receivers and high accuracy clocks to determine the position of an object. The Global Positioning System A constellation of 24 highaltitude satellites GPS is A constellation of satellites, which orbit the earth twice a day, transmitting precise time and position (Latitude, Longitude and Altitude) Information. A complete system of 21 satellites and 3 spares. GPS at Work 1. Navigation - Where do I want to go? 2. Location 3. Tracking 4. Mapping - Where am I? - Monitoring something as it moves - Where is everything else? 5. Timing - When will it happen? Why do we need GPS? Safe Travel Traffic Control Resource Management Defense Mapping Utility Management Property Location Construction Layout 4 ‘birds’ (as we say) for 3-D fix Global Positioning Systems (GPS) Applications in Power Systems Power companies and utilities have fundamental requirements for time and frequency to enable efficient power transmission and distribution. Repeated power blackouts have demonstrated to power companies the need for improved time synchronization throughout the power grid. Analyses of blackouts have led many companies to place GPS-based time synchronization devices in power plants and substations Why GPS For power Eng It furnishes a common-access timing pulse which is accurate to within 1 microsecond at any location on earth. A 1-microsecond error translates into 0.021° for a 60 Hz system and 0.018 ° for a 50 Hz system and is certainly more accurate than any other application GPS time synchronization By synchronizing the sampling processes for different signals – which may be hundreds of kilometers apart – it is possible to put their phasors in the same phasor diagram GPS time synchronization V1 V V1 Ψ Substation 1 V2 FFT or any other technique gives: •Magnitude •Phase angle With respect to GPS V Substation 2 t1 t2 t3 t4 t5 t6 t7 GPS time synchronized pulses V2 Absolute Time Reference Across the Power System Phasor Measurement Units PMUs Synchronized phasor measurements (SPM) have become a practical proposition. As such, their potential use in power system applications has not yet been fully realized by many of power system engineers. Phasor Measurement Units (PMU) [or SYNCHROPHASORS] Phasor Measurement Units PMUs Phasor Measurement Units )PMU) They are devices which use synchronization signals from the global positioning system (GPS) satellites and provide the phasor voltages and currents measured at a given substation. Phasor Measurement Units PMUs input Secondary sides of the 3Φ P.T. or C.T. PMU output Corresponding Voltage or Current phasors Phasor Monitoring Unit (PMU) Hardware Block Diagram: GPS receiver Analog Inputs Anti-aliasing filters Phase-locked oscillator 16-bit A/D converter Modems Phasor microprocessor Sampling at Fixed Time Intervals Using an Absolute Time Reference v LPF A/D ¦s Time Synch GPS Clock Synchronized Phasor The GPS receiver provides the 1 pulse-per-second (pps) signal, and a time tag, which consists of the year, day, hour, minute, and second. The time could be the local time, or the UTC (Universal Time Coordinated). The l-pps signal is usually divided by a phase-locked oscillator into the required number of pulses per second for sampling of the analog signals. In most systems being used at present, this is 12 times per cycle of the fundamental frequency. The analog signals are derived from the voltage and current transformer secondary's. The Birth of the PMUs Computer Relaying developments in 1960-70s. ABB Now SEL-421 RES 521 ABB Phasor Measurement Unit’s Phasor Measurement Units PMUs central data collection Data Concentrator (Central Data Collection) ABB Different applications of PMUs in power system Applications of PMU in power 1. Adaptive relaying System 2. Instability prediction 3. State estimation 4. Improved control 5. Fault recording 6. Disturbance recording 7. Transmission and generation modeling verification 8. Wide area Protection 9.Fault location Applications of PMU in power System 1-Adaptive relaying Adaptive relaying is a protection philosophy which permits and seeks to make adjustments in various protection functions in order to make them more tuned to prevailing power system conditions Applications of PMU in power System 2-Instability prediction • The instability prediction can be used to adapt load shedding and/or out of step relays. • We can actually monitor the progress of the transient in real time, thanks to the technique of synchronized phasor measurements. Applications of PMU in power System 3-State estimation • The state estimator uses various measurements received from different substations, and, through an iterative nonlinear estimation procedure, calculates the power system state. • By maintaining a continuous stream of phasor data from the substations to the control center, a state vector that can follow the system dynamics can be constructed. • For the first time in history, synchronized phasor measurements have made possible the direct observation of system oscillations following system disturbances Applications of PMU in power System 4-Improved control • Power system control elements use local feedback to achieve the control objective. • The PMU was necessary to capture data during the staged testing and accurately display this data and provide comparisons to the system model. • The shown figure shows a typical example of one of the output plots from the PMU data Applications of PMU in power System 5-Fault Recording • They can capture and display actual 60/50 Hz wave form and magnitude data on individual channels during power system fault conditions. Applications of PMU in power System 6-Disturbance Recording • Loss of generation, loss of load, or loss of major transmission lines may lead to a power system disturbance, possibly affecting customers and power system operations. Applications of PMU in power System Disturbance Recording These figures are examples of long-term data used to analyze the effects of power system disturbances on critical transmission system buses. Applications of PMU in power System 7-Transmission and Generation Modeling Verification • Computerized power system modeling and studies are now the normal and accepted ways of ensuring that power system parameters have been reviewed before large capital expenditures on major system changes. • In years past, actual verification of computer models via field tests would have been either impractical or even impossible • The PMU class of monitoring equipment can now provide the field verification required Applications of PMU in power System 7-Transmission and Generation Modeling Verification • The shown figure compares a remote substation 500 kV bus voltage captured by the PMU to the stability program results Applications of PMU in power System 8-Wide – Area protection The introduction of the Phasor Measurement Unit (PMU) has greatly improved the observability of the power system dynamics. Based on PMUs, different kinds of wide area protection, emergency control and optimization systems can be designed Applications of PMU in power System 9-Fault Location A fault location algorithm based on synchronized sampling. A time domain model of a transmission line is used as a basis for the algorithm development. Samples of voltages and currents at the ends of a transmission line are taken simultaneously (synchronized) and used to calculate fault location. Applications of PMU in power System The Phasor measurement units are installed at both ends of the transmission line. The three phase voltages and three phase currents are measured by PMUs located at both ends of line simultaneously Fault Location PMU A Synchroniz ed phasor Modal Transform of synchronized samples PMU B Synchroniz ed phasor SPM-based applications in power systems off-line studies real-time monitoring and visualization real-time control, protection and emergency control 42 SOME RESEARCH PROGECTS (I participated in) Global Positioning System (GPS)Based Synchronized Phasor Measurement By Eng .Marwa M. Abo El-Nasr Supervised by Prof. Dr. Mohamed M. Mansour Dr. Said Fouad Mekhemer CONCLUSIONS The conclusions extracted form the present work can be summarized as follows: 1. A technique for estimating the fault location based on synchronized data for an interconnected network is developed and implemented using a modal transform 2. One-bus deployment strategy is more useful than tree search for fault location detection as it gives more system observability Conclusions 3- The average value of mode 1 and 2 of Karrenbauer transformation is used for 3-phase and line-to-line faults, while the average value of the 3 modes is used for line-to-line-ground and line-to-ground faults 4- The results obtained from applying the developed technique applied to a system depicted from the Egyptian network show acceptable accuracy in detecting the fault and locations of different faults types. Essence: This thesis is to address three issues: 1- Optimal allocation of Phasor Measurement Units (PMUs) using Discrete Particle Swarm Optimization (DPSO) technique. 2- Large scale power system state estimation utilizing the optimal allocation of PMUs based on Global Positioning Systems (GPS). 3- Power system voltage stability monitoring based on the allocated PMUs’ readings. WIDE AREA PROTECTION SYSTEM FOR MAXIMIZING POWER SYSTEM STABILITY Prepared By Fahd Mohamed Adly Hashiesh Under Supervision of Prof. Dr. M. M. Mansour Dr. Hossam Eldin M. Atia Dr. Abdel-Rahman A. Khatib Cairo – Egypt 2006 49 Research Objective Propose a protection system (strategy) to counteract wide area disturbance (instability), through employing adaptive protection relays, and fast broadband communication through wide area measurement. Configure and adapt the proposed system to be applied on Egypt wide power system network. 50 A Master Student is Trying to Implement a PMU Lab Prototype in Ain-Shams Univ. CONCLUSIONS AND FUTURE WORKS thanks to their multiple advantages, nowadays, the technologies based on synchronized phasor measurements have proliferated in many countries worldwide (USA, Canada, Europe, Brazil, China, Egypt !,..). up to now most applications based on synchronized phasor measurements have concerned mainly off-line studies, on-line monitoring and visualization, and to a less extent the real-time control, Protection, and the emergency control. the toughest challenge today is to pass from Wide Area Measurements Systems (WAMS) to Wide Area Control Systems (WACS) and WAP. 52 Off-line SPM-based applications software simulation validation SPM-based technologies can be very useful to help the validation of (dynamic) simulation software system parameter/model identification (e.g. for loads, lines, generators, etc.) the identification of accurate model/parameter is a very important and tough task for the power system analysis and control. difficulty: large number of power system components having timevarying characteristics. synchronized disturbances record and replay this task is like that of a digital fault recorder, which can memorize triggered disturbances and replay the recorded data if required. the use of SPM allows more flexibility and effectiveness. 54 Real-time monitoring SPM-based applications fault location monitoring accurate fault location allows the time reduction of maintenance of the transmission lines under fault and help evaluating protection performance. power system frequency and its rate of change monitoring the accurate dynamic wide-area measured frequency is highly desirable especially in the context of disturbances, which may lead to significant frequency variation in time and space. generators operation status monitoring this function allows the drawing of generator (P-Q) capability curve. Thus, the generator MVAr reserve, can be supervised. transmission line temperature monitoring the thermal limit of a line is generally set in very conservative criteria, which ignores the actual cooling possibilities. The use of SPM allows the higher loading of a line at very low risk. on-line "hybrid" state estimation the SPM can be considered, in addition to those from the Remote Terminal Units (RTU) of the traditional SCADA system, in an on-line "hybrid" state estimation. SPM-based visualization tools used in control centers display: dynamic power flow, dynamic phase angle separation, dynamic voltage magnitude evolution, real-time frequency and its rate of change, etc. 55 Real-time (emergency) control SPM-based applications automatic (secondary and tertiary) voltage control aim: optimize the var distribution among generators, controllable ratio transformers and shunt elements while keeping all bus voltage within limits. in the context of WAMS application, the solution of this optimization problem can be used to update settings of those reactive power controllers, every few seconds. damping of low frequency inter-area oscillations (small-signal angle instability) low frequency inter-area oscillations (in the range of 0.2 – 1 Hz) are a serious concern in power systems with increasing their size and loadability. In Europe, in particular, many research studies have been performed to reveal such oscillations as well as provide best remedial actions to damp them out. transient angle instability since such instability form develops very quickly, nowadays, Special Protection Systems (SPS), also known as Remedial Action Schemes (RAS), are designed to act against predefined contingencies identified in off-line studies while being less effective against unforeseen disturbances. 56 Real-time (emergency) control SPM-based applications (cont’d) short- or long-term voltage instability a responde-based (feedback) Wide-Area stability and voltage Control System (WACS) is presently in use by BPA. this control system uses powerful discontinuous actions (switching on/off of shunt elements) for power system stabilization. frequency instability the underfrequency load shedding has its thresholds set for worst events and may lead to excessive load shedding. new predictive SPM-based approaches are proposed aiming to avoid the drawbacks of the conventional protection. 57 Conclusions: A- Discrete Particle Swarm Optimization Technique: • A new modified DPSO technique is developed to determine the optimal number and locations for PMUs in power system network for different depths of unobservability. It gives the optimal PMUs' allocation for different depths of unobservability comparable to other techniques • The developed DPSO is tested on both 14-bus and 57-bus IEEE standard systems. • For small power systems, DPSO gives either equivalent or better results. However for large power systems, it gives almost better locations and sometimes less number of PMUs for large power systems. • DPSO determines the optimal PMUs' allocation for complete observability of the large system depicted from the Egyptian unified electrical power network. Conclusions (continued): B- Hybrid State Estimation Technique: • The phasors readings of PMUs are taken into consideration in a new hybrid state estimation analysis to achieve a higher degree of accuracy of the solution. • The effect of changing the locations and numbers of PMUs through the buses of the power network on the system state estimation is also studied with a new methodology. • The hybrid state estimation technique is tested on both 14-bus and 57-bus IEEE standard systems. It is also applied to a large system depicted from the Egyptian unified electrical power network. • PMUs' outputs affect the state estimation analysis in a precious way. It improves the response and the output of the traditional state estimation. Conclusions (continued): • The locations of PMUs according to state estimation improvement do not need to be similar to those locations according to observability depth. • The system parameters, system layout and power flow affect the PMUs' positioning for optimal state estimation. • For each system there is a certain number of PMUs with certain connections that reduces the estimation error significantly. As the number of PMUs' increases over the optimal solution, the estimation analysis begins to magnify the measurements error of the other devices. Conclusions (continued): C- On-line Voltage Instability Alarming Predictor: • The readings of the allocated PMUs are to be utilized using a newly developed technique for on-line voltage instability alarming predictor. • The predictor gives two types of alarms, one for voltage limit violation (10% voltage decrease) and the other for voltage collapse prediction according to the maximum permissible angle difference between bus voltages for certain bus loading angle. • The time taken by the alarming predictor is small, and is determined by the speed of PMUs and the used computational system. • The voltage instability alarming predictor concept is tested on both 14-bus IEEE standard system. It gives effective results. • The alarming predictor is applied to the large system depicted from the Egyptian unified electrical power network, with the aid of the voltage instability limits calculation of the system.