* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download BE1-GPS Product Screenshow
Ground loop (electricity) wikipedia , lookup
Current source wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Chirp spectrum wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical substation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Power electronics wikipedia , lookup
Crossbar switch wikipedia , lookup
Mains electricity wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Alternating current wikipedia , lookup
Control system wikipedia , lookup
Digital electronics wikipedia , lookup
Earthing system wikipedia , lookup
BE1-GPS100 Generator Protection System BE1-GPS100 What is it? Generator Protection System based on the successful 851/951 platform • Includes Multifunction Protection and: – Metering and Control – Relay Status Alarms – Breaker Monitoring – Detailed Event and Oscillography Data – Communication (Status, Metering, Control, Settings, Events) – Programmable Logic – Programmable I/O BE1-GPS100 What makes it unique? • High Flexibility – Flexibility in protection settings – Flexibility in application logic – Flexibility in packaging (H1 and S1 case) • Optimal functionality in a small package Typical BE1-GPS One Line 52 VX on Broken Delta, 3Vo, gen neutral 24 x81 O/U 47 x27N x59N x27P x59P Bus VX* 3,2 25 * VX: one optional phase voltage input usable for either gen neutral or sync check G 46Q 50TN 50TP BF 51N 51P x40Q x32 151N VR/VC 60FL 3 x50/51N: 3Io or Ig VX, Ig Optional IE Logic x62 27-3N 1 neu VX* R or X + Front Display, RS232 ASCII, RS485, ASCII/Modbus/DNP, Oscillography, SOE, 2 Setting Groups, Programmable Logic, 4 status in, 6 contact out BE1-GPS100 Protection - Current • 51V: Phase Overcurrent – Settable for: * Voltage Controlled (51/27C) * Voltage Restrained (51/27R) * Normal (51) – Multiple time curves using IEEE C37.112-1996: * 7-CO, 5-IAC, 4-IEC, 1-fixed, 1-programmable * Each with instantaneous or integrating reset • 51N, 151N – Each can be assigned to: * Three Phase Residual-3I0 (IN) * Optional Independent Ground Input (IG) BE1-GPS100 Protection - Current • 46: Negative Sequence Overcurrent – Accepts K factor based I2 curve or – Standard time overcurrent curves • BF: Breaker Failure – Timer with fast dropout current detector – Supervise / Block with either internal elements or external inputs – Start / Initiate with either internal elements or external inputs BE1-GPS100 Protection - Current • 50TP: Phase Instantaneous / Def. Time – – – – Use for Inadvertent Energization logic or On line indication or Phase fault protection or User-defined purpose • 50TN: Ground Inst. / Def. Time – Use for Inadvertent Energization logic or – Ground fault protection or – User-defined purpose BE1-GPS100 Protection - Current • 51N monitoring Optional Independent Ground Input can act as OC differential. • For those applications requiring Generator Differential (87): Use the BE1-87G or the BE1-CDS220 – Redundancy gained by placing the differential in a separate package avoids the “all your eggs in one basket” pitfall • Basler offers competitive pricing for the CDS220/GPS100 combo package BE1-GPS100 Protection - Voltage • 24: Volts/Hertz – Inverse quantity squared curve * Time delay proportionate to (1/(M-1)^2) • 25: Sync Check – dV, dF, df – Sync allowed on gen. frequency>bus frequency if desired – Instantaneous response; no time delay needed, but can be added with 62 timer BE1-GPS100 Protection - Voltage • 27P, 127P: Phase Undervoltage • 59P, 159P: Phase Overvoltage – Unique user selected 1/3, 2/3, or 3/3 logic – Definite time • 47: Negative Sequence Voltage – Reverse phase energization detection – Applicable for mobile generators – Definite time BE1-GPS100 Protection - Voltage • 27X, 127X, 59X, 159X : Auxiliary Over and Under Voltage – Definite Time – 3 User Selected Modes - Mode 1: Aux VT, fundamental frequency * Monitor bus or monitor generator neutral for ground fault - Mode 2: Phase VT, 3Vo * Monitor generator high side for ground fault - Mode 3: Aux VT, 3rd Harmonic * Absence of neutral 3rd harmonic indicates ground fault BE1-GPS100 Protection - Voltage • 60FL: Fuse Loss Detection Algorithm – Negative Sequence Voltage in the absence of negative sequence current – Loss of all phase voltages with no phase current, with breaker closed • 81, 181, 281, 381: Over / Under Frequency – Definite time – Frequency set points can be Over or Under – Undervoltage blocking BE1-GPS100 Protection - V x I • 32, 132: Forward or Reverse, Over or Under Power (Under with user supplied logic) – Use for Loss of Prime Mover – Online indication – Sequential tripping • 40Q, 140Q: Loss of Excitation – Definite Time – Offset Sloped VAR Flow Algorithm – Set one Fast/High; 2nd Slow/Low BE1-GPS100 Auxiliary Timers • 62, 162, 262, 362: General Purpose Logic Timers – Multiple Modes of Operation * * * * * Pickup / Drop Out One Shot, Retriggerable One Shot, Non-retriggerable Integrating Timer Latch – Very Long PU and DO Time delays * 0.000-9999s (2.78hrs) BE1-GPS100 Control • Virtual Control switches in the relay replace panel mounted switches – Controllable from relay HMI or via serial ports – 101 Breaker Control switch * 3 Outputs: 101T (Pulse Trip), 101C (Pulse Close), 101SC (Slip Contact) – 43, 143, 243, 343 switches * 3 modes: On / Off; Off / Momentary On; On / Off / Pulse * User settable labels BE1-GPS100 Switchable Setting Groups • Two settings groups for addressing different operating conditions – Controlled via Programmable Inputs – Control via 43 switches – Settings are independent – Setting Group can change logic Typical One Line BE1-GPS100 PRIME MOVER G FIELD GND FLT LOGIC 3RD 151N 27X 159P 159X 32 24 132 27P 81 40Q 47 181 140Q 59P 281 159P 381 3Vo 59X IN2 SIMULTANEOUS TRIP 101 (T) 51V TIMER Unused Functions 25 IN4 127P 143 50BF 243 127X 343 SEQUENTIAL TRIP IN3 43 46 60FL 50P 50N 51N I.E. LOGIC IN1 BE1-GPS100 • • • • • Metering Functions Volts: ph-ph, ph-n Amps: Ph, N, Gnd, Neg Sequence Watts, VARS, Forward/Reverse Watt-Hours, VAR-Hours Read from – BESTCOMS – Front HMI – ASC commands – SCADA access via com. ports Metering Functions BE1-GPS100 Metering Functions • Demand – Amps: per phase, ground, negative seq. – Watts, VARs, Forward / Reverse – Demand Alarms – Today's, yesterday's, peak since reset – Demand interval separately settable for phase, neutral, and negative sequence BE1-GPS100 Settings File Documentation • Use BESTCOMS to print or export all settings with a single click • Five pages of detailed settings • Fast and easy settings documentation BE1-GPS100 Detailed Event Reports • 16 Fault Summary Reports – Includes tripping elements, targets, current, voltage, duration • 255 Sequence of Events – SOE includes all logic changes of state and all protective element and I/O pu/do • 240 Cycle Oscillography – View with free BESTwave software – Divided over 6-16 events (user setting) – 12 samples / cycle BE1-GPS100 Alarms • 4 Types of Alarms: – Relay Fail, Major, Minor, or Logic • Front Panel includes LEDs for Relay Trouble, Major, and Minor Alarms • Relay Fail Contact Output • Continuous self test • Reset alarms via Contact Input or Logic command BE1-GPS100 Breaker Monitoring • Accumulation of interrupted I or I • Provisions to disable breaker duty 2 during test current injection • Operations counter • Excessive clearing time • Built-in trip circuit monitor (Output 1) BE1-GPS100 • • • • • • • • I/O 3 Phase CTs, 1 or 5 A Optional Independent Gnd CT, 1 or 5 A 3 Phase VTs, 3W, 4W, or 1 Ph 1 Aux VT (Gen Neutral or Bus) 4 Programmable Status Inputs 5 Programmable + 1 Alarm Outputs 3 Communication Ports Front Panel: LCD display with 5 virtual switches BE1-GPS100 • • • • Advanced Human Machine Interface Programmable scroll list You can't get lost in the menu tree Automatic priority of target and alarm displays Most settings changeable via HMI – Logic setup requires com. port access BE1-GPS100 Integration Friendly Features • Virtual Switches replace physical switches for local and remote control • Metering, Alarm, and Status Reporting • Three Independent Communications Ports with optional protocol support – Modbus – DNP 3.0 Level 2 Certified BE1-GPS100 • • • • Communications Three independent general purpose com ports All are optically isolated ASCII command communications Free Windows based software included for setting and interrogation of the relay • Protocol support for Com2 (RS-485 port on rear) • IRIG-B port is standard (external time sync) BE1-GPS100 Security • Three access areas with independent passwords • Master access password • Security independently settable for each port BE1-GPS100 Hardware Features • Flash memory for embedded programming • Active CT technology • Power supply holds up to 100ms with 4 output relay energized upon complete loss of power • Full drawout half rack and S1 case BE1-GPS100 Mounting Half Rack Case (H1) Mounting Accessories Two Escutcheon Plates available: • • Panel mounts one H1 type relay Panel mounts two H1 type relays dovetailed side-by-side Two Adapter brackets available: • Mounts single H1 case relay in a 19” rack –with cutout for FT test switch –without cutout for FT test switch BE1-GPS100 What about mounting? S1 Case with Test Paddle Mounting Accessories Fits in same size cutout as Basler and GE S1 case Available in S1 single and double ended Cases Two Adapter Plates available: • • Mounts S1 case in GE S2 or West. FT21 cutout Mounts S1 case in West FT32 cutout BE1-GPS100 Windows Software Free BESTCOMS™ with Every Relay • System Setup Summary Screen shows all enabled functions • Screens are provided for the operational setting of each protective function • Screens are provided to aid making BESTlogic settings BE1-GPS100 Windows Software Free BESTCOMS™ with Every Relay • System Setup Summary Screen shows all enabled functions • Screens are provided for operational setting of each protective function • Screens are provided to aid making BESTlogic settings BE1-GPS100 Windows Software Free BESTCOMS™ with Every Relay • System Setup Summary Screen shows all enabled functions • Screens are provided for the operational setting of each protective function • Screens are provided to aid in making BESTlogic settings BE1-GPS100 FLEXIBILITY Application Logic BESTlogic • Highly flexible programming language • Equivalent to combining discrete component with user defined Boolean logic • User has the same flexibility as in the days before multifunction relays • Evaluation effort is reduced BE1-GPS100 FLEXIBILITY Application Logic • User defined Inputs and Output Application – Customize to application • User defined variable names – Easier to analyze event reports – Allows virtual switch name to be customized to application BE1-GPS100 BESTlogic Select a Pre-programmed Scheme OR Program a Custom Logic Scheme BE1-GPS100 BESTlogic Example: Virtual Selector switch Mode = 0 - disable 1 - on/off or pulse 2 - on/off only 3 - pulse only HMI or Communication Port Command 43 10 character User defined name for switch 7 Character User defined name for OFF state 7 Character User defined name for ON state Virtual switches: 43, 143, 243, 343 BE1-GPS100 BESTprint • BESTPRINT allows users to preview and print graphical representations of BESTCOMS settings files. • 15 pages of detailed documentation BE1-GPS100 Questions?