P 505 Statistical Determination of Insulator Performance at Koeberg Insulator Pollution Test Station Presented by Dr WL Vosloo (Eskom) Dr I Gutman (STRI) Dr JP Holtzhausen (University of Stellenbosch) Typical Performance Data at KIPTS Electrical Performance with Natural Pollution Natural Ageing Performance Note: E-1 and F are the reference insulators at KIPTS and was not chosen as the optimum solution for this area. Strength P() Stress f() f ( ) P( ) Risk for flashover Strength: probability for flashover Stress: density of occurrence Statistical Approach Pollution severity() 1. 2. 3. Pollution stress at site: probability density function f() Probability for flashover at maximum operating voltage: cumulative distribution function P() Multiplication of f() and P() – the area under this curve defines the risk for flashover Pollution stress at site: probability density function f() The site ESDD in mg/cm2 can be calculated from: ESDDSite 1 where: = I U 150 (empirically determined factor) I 1 Kf U 2 where: = = = = I U Kf Kf L 0 conductivity of the pollution layer in μS peak leakage current in A peak phase voltage in kV insulator form factor Measured on Insulator at KIPTS ds 2 R( s) where: S L R(s) = = = the distance measured along the profile of the insulator creepage path length insulator radius at distance ‘s’ Probability for flashover at maximum operating voltage: cumulative distribution function P() U 50% A K f n n 1 1 n 1 L n n 1 where: A n = = 2.27 (empirically determined factor) 0.35 (empirically determined factor) I 1 Kf U 2 NCI totally Hydrophilic where: I U Kf = = = = Kf L 0 conductivity of the pollution layer in μS peak leakage current in A peak phase voltage in kV insulator form factor Measured on Insulator at KIPTS ds 2 R( s) where: S L R(s) = = = the distance measured along the profile of the insulator creepage path length insulator radius at distance ‘s’ Calculated Number of Flashovers per Insulator per year Determine What Insulation to Use Predict In Service Insulation Performance Transmission Line Calculated faults per year Actual faults per year A 0,6 1,0 B 1,0 0,5 C 0,2 0,5 Future Work • Further investigate the use of leakage current data measured on all insulators tested at KIPTS so as to determine there statistical performance curves • Determine statistical performance curves for various standard insulators in the laboratory (ac and dc) • Establish a methodology where both sets of data can be used so as to help Eskom select insulators for the power network Thank You Thank You