* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Altech/ABL Sursum Miniature Circuit Breakers
Electrical ballast wikipedia , lookup
Three-phase electric power wikipedia , lookup
Thermal runaway wikipedia , lookup
Electric power system wikipedia , lookup
Electric machine wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
History of electric power transmission wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Buck converter wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Protective relay wikipedia , lookup
Fault tolerance wikipedia , lookup
Induction motor wikipedia , lookup
Opto-isolator wikipedia , lookup
Mains electricity wikipedia , lookup
Flexible electronics wikipedia , lookup
Stepper motor wikipedia , lookup
Regenerative circuit wikipedia , lookup
Ground (electricity) wikipedia , lookup
Integrated circuit wikipedia , lookup
Surge protector wikipedia , lookup
Electrical substation wikipedia , lookup
Alternating current wikipedia , lookup
RLC circuit wikipedia , lookup
Residual-current device wikipedia , lookup
Earthing system wikipedia , lookup
Miniature Circuit Breakers Sales Training Outline 2006 Klaus Tum Product Manager 35 Royal Road Flemington, NJ 908-806-9400 www.altechcorp.com Klaus Tum (short bio) • Electrical Engineer • 10 years with Altech Corporation • Product Manager of Circuit Breakers, Busbars, Motor Disconnect Switches, Foot Switches, Sensors, Contactors, Motor Starters, Pin & Sleeve Connectors Altech’s Line of Circuit Breakers Includes: • • Miniature circuit breakers -UL508 • Three phase adjustable trip circuit breakers • Earth leakage circuit breakers • Accessories Introduction • The Altech Miniature Circuit Breaker (MCB)/ Manual Motor Controller is a circuit protection device, which is able to protect the wiring and the loads of electrical circuits. • These MCB’s are a Thermal-Magnetic type circuit breaker. • The wiring/cabling will be protected from overloads by the MCB’s Thermal part and the loads (motors, heaters, power supplies, etc.) will be protected from short circuits by its magnetic parts. • NOTE: The Altech MCB can only be used as a “supplementary Protector”. It CANNOT be used as a branch circuit protector (Molded Case Circuit Breaker (MCCB) or UL listed RK5 fuse). General Specifications • Manual Motor Controller UL 508 Listed suitable for Motor Disconnect Means. DIN Rail mountable • Electrical ratings: 0.3A up to 60A, 480Y/ 277VAC • Interrupting capacity: 10kA (with back-up fuse) • Group ratings: 5 and 10kA (without circuit branch protection) • Thermal magnetic type • Six different trip characteristics: – B, C, D, E, G, Z – UL, CSA, CE • 1, 2, 3 pole and 1 & 3 pole plus neutral configurations • Accessories – Auxiliary Switch (UL508 Listed) – Shunt Trip (UL508 Listed) – Undervoltage Trip • UL508 Listed Busbar Distribution System Thermal-Magnetic Principle Main Current & Arc Current Limiting Path ______________ Main (line) Current Path ---------------- Arc Current Limiting Path Thermal Principle (Overload Protection) • The thermal part of the circuit breaker utilizes a bimetallic strip electrically in series with the circuit. The heat generated by the current during an overload deforms the bimetallic strip and trips the circuit breaker. – Example: • Overload occurs when the vacuum is obstructed and the power cord gets overheated. – NOTE: The thermal part of the circuit breaker is temperature sensitive and can be adversely affected by changes in ambient temperature (MCB calibrated at 40° C (104° F) ). Magnetic Principle (Short Circuit Protection) • The magnetic part of the circuit breaker consists of an electromagnetic coil and an armature device that opens the movable contact quickly to protect the circuit whenever the current (short circuit current) exceeds a predetermined value. This happens because the current in the coil generates sufficient magnetic flux to attract the armature. Reset is manual and rapid. – Example: • Short circuit occurs when the hot wire and neutral/ground accidentally come together. Trip-Characteristics & Applications Section A Overload Y Time Z X V Section B Short Circuit W U Current Time Trip-Characteristics & Applications Z Section A Overload Y Current Section A- Overload • This section reflects the protection behavior of the circuit breaker when an overload occurs. Usually the overload increases its value above the rated current slowly. – The left line shows when the MCB does not trip. – The right line is the opposite, the MCB must trip! – The middle black line indicates the “ideal” trip curve. Due to manufacturing tolerances and surrounding influences, the MCB can only be calibrated “around” this line. Trip-Characteristics & Applications Short Circuit Time Section B X V U W Current Section B - Short Circuit • This section reflects the protection behavior of the circuit breaker in the case of an inrush current or a short circuit. – Inrush current occurs when the load is turned on and off (the inrush of a regular motor is approximately 6x the rated current). It is VERY important to know the inrush current when selecting the proper circuit breaker. The time of an inrush is usually between 100-500ms. If the correct circuit breaker is selected it will be insensitive to the inrush current (see points “X” & “W”). The circuit breaker will trip if the current exceeds 16XRC in 100ms (see point “V”). Section B Short Circuit Time Section B - Short Circuit - Continued X V U W Current – Short Circuit Current is the current which occurs in the case of a hot wire and ground/neutral coming together. • This current is usually very high (between 300A - 2000A) and the circuit breaker will trip within milliseconds. Note: If the MCB has a rated current of 10A, it will trip in 7ms, if the short circuit current is 400A (see point “U”). TIME The B-Trip Characteristic CURRENT • • Applications – Business equipment, wiring protection, lighting, appliances, control circuits, some motors and some electronic circuits Available current – 0.3A-60/63A The C-Trip Characteristic • • Applications – Low inrush, 3-4x rated current, motors, lighting, wiring protection, appliances, business equipment, control circuits Available current – 0.3A-60/63A The D-Trip Characteristic • • Applications – High inrush, 10-16x rated current, motors, transformers, power supplies, heaters, reactive loads Available current – 0.3A-60/63A The E-Trip Characteristic • • Application – High efficiency motors, which have very high inrush, 12x rated current Available current – 0.3-60/63A The G-Trip Characteristic • • Applications – General industrial, including motors, some transformers, solenoids, control circuits, lighting, wiring Available current – 0.3-60/63A The Z-Trip Characteristic • • Applications – Semiconductors, components with low surge current and short circuit withstand capabilities Available current – 0.3-50A Summary of Applications/Trip Curve Selection Guide Summary of Applications/Trip Curve Selection Guide (Continued) . UL 508 Style • Catalog number will be imprinted on the Circuit Breaker as shown in the picture to the left “1BU16” (1 pole, B-Trip characteristic, UL Type, 16 A). UL 1077/ UL 508 Comparison • • UL1077 – MCB can only be used by UL certified/ approved panel shops – MCB is only “recognized”, which means the entire panel consisting of recognized components needs additional approval by a UL inspector UL508 – MCB is “listed” – Every Licensed Electrician can use the MCB, not only a UL Panel Shop – Manual Motor Controller is suitable for motor disconnect – Tested for these applications: – AC Motor Starting, Across the line – AC General use – AC Resistance – AC Discharge Lamps (Ballast) – AC Incandescent Lamps (Tungsten) Competitors (V-EA, MA Circuit Breakers) • Crossable in fit, form and function-> DIN Rail mountable, European style, Thermal-Magnetic MCB. – ABB (S230-S280 series) – AEG System (ELFA series) – Airpax (IELR series) – Allen-Bradley (1492-MCB series) = Weber(AS 168 series) – Carlingswitch (D-Series) – Cutler - Hammer (SPCL - series) – ETA (42-01 series & 91 series) – GE (V-Line series) – Klöckner - Möller (FAZ-series) – Phoenix (TMC series) – Siemens (5S-series) – Square-D (Merlin Gerin multi 9 series) – Square-D Telemacenique (GB 2-MCB series, etc.) – Weidmüller (MCB series) • Only crossable if customer is able and willing to change panel/circuit design – Eaton/Heinemann – IDEC – Potter & Brumfield Target Customers • Panel shops • Machine manufacturers which provide complete packages • Any industrial plant • Licensed electricians/ contractors Why Altech? • UL 508 LISTED • High Quality • Complete line with the most various trip characteristics to meet all application needs • Most circuit breakers in stock • Price competitive in 10KA versions • One source can provide almost complete power distribution solutions (busbars, terminal blocks, enclosures, etc.) MA Three Phase Adjustable Trip Miniature Circuit Breaker UL508 listed CAN/CSA-C22.2 No. 14 certified C MA Three Phase Adjustable Trip Miniature Circuit Breaker The MA was designed to handle the high inrush loads of 3 phase transformers, power supplies, motors, etc. • • General Specifications – Complies with various national and international standards e.g. UL, CSA, VDE, IEC, CE – DIN Rail mountable – Adjustable thermal trip allows finalization of initial designs before procurement of the load equipment is complete – Voltage rating: 480Y/277 V AC – Rated current from 0.16A - 40A – 3 poles Accessories available (same as V-EA MCB) – Auxiliary Switch – Shunt Trip – Undervoltage Trip V-EA and MA Circuit Breaker Accessories Accessories can be factory or field mounted on V-EA miniature circuit breakers and MA motor protection switches for enhanced control and monitoring capabilities. Field mounting kits include all necessary parts and instructions. Accessories can be gang mounted on a single breaker (the Auxiliary Switch in the outside position). The mounting arrangement links the internal latch-pins for the tripping mechanisms, ensuring simultaneous trips. Handles are linked to simplify manual resetting. Remote Trip-Shunt Trip • Coil actuated, the FA Shunt Trip allows electrical remote tripping of a breaker. It is trip-free and the housing and terminal specifications are the same as for V-EA miniature circuit breakers. • The Shunt Trip contains its own contacts which break the tripping power circuit when tripped. It is available with trip-coils in the most standard control voltages. FA Undervoltage Trip Re-power your system under controlled conditions following a power loss or serious undervoltage. Altech UA Undervoltage Trips are coupled to the tripping latch pins of the VEA or MA to which they are attached, reliably producing trips at the drop-out voltage and preventing resetting when less than 85% line voltage is present. The Undervoltage Trip is provided with at least 6-inch pigtails of stranded fixture wire for hook-up to the V-EA or MA line terminals. • Reset-Hold Voltage = 0.85 x Ve • Drop-Out Voltage = 0.35 to 0.7 x Ve UA Auxiliary Switch H11U • Altech H Auxiliary Switch is suitable for logic interrogation and for use as a two-circuit Form C contact. It can also function as an auxiliary switch for control circuits. More Accessories FI Earth Leakage Circuit Breakers • FI compact Earth Leakage Circuit Breakers detect and interrupt earth (ground) faults. They are VDE approved for the European system of protecting people, animals, equipment and property from dangerous line-to-ground and shock hazard currents. – For example: • The insulation of shockproof equipment or their leads is defective. • The earth wire is interrupted. • Earth wire and live wire have been transposed accidentally, thus rendering live the body of a protection Safety Class I device. • A component which is live in normal operation is touched during repairs. Continued FI 2 FI 4 • General Specifications – DIN Rail mountable – Voltage rating: 415Y/240VAC – Maximum rated line current from portable power supply 16A - 63A – Fault Trip current from 10mA - 300mA • Fault Trip Current Calibration – FI trips are calibrated at less than fault trip current for ensured safety (Typical trip range between 66.6-83.3% fault trip current, e.g. typical trip at 20-25mA for fault RC of 30mA) Principle of Operation • In the event of a short to earth, the residual current operated system prevents shock-hazard voltages from remaining on the body of Safety Class I electrical equipment or machines. For this purpose, the FI Earth Leakage Circuit Breaker monitors the difference between loads flowing through it and ensures that is approximately zero. If, as a result of an earth fault, this difference exceeds the circuit breaker’s residual operating current rating, then the FI will disconnect the faulty equipment. Fault Current Circuit Residual Current Circuit Busbar Distribution System • The Altech Busbar Distribution System is an innovative way to jumper up to 57 poles of Altech Miniature Circuit Breakers (MCB)/ Manual Motor Controllers (MMC). • Advantages: – – – – – Installation time savings Panel space savings Little or no maintenance High electrical ratings Busbars maintain UL approval, even after being cut Busbar Distribution System Busbar Ordering Information Busbar Ordering Information Power Feed Devices Assembly Two Power Feed Methods