* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ECEN5817L38 - University of Colorado Boulder
Power factor wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power over Ethernet wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power inverter wikipedia , lookup
Electrification wikipedia , lookup
Audio power wikipedia , lookup
Opto-isolator wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electronic engineering wikipedia , lookup
Printed electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Electric power system wikipedia , lookup
Distribution management system wikipedia , lookup
Mains electricity wikipedia , lookup
Power engineering wikipedia , lookup
Wireless power transfer wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Alternating current wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Zero-voltage transition converters The phase-shifted full bridge converter Buck-derived full-bridge converter A popular converter for server frontend power systems Zero-voltage switching of each halfbridge section Each half-bridge produces a square wave voltage. Phase-shifted control of converter output ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 1 Efficiencies of 90% to 95% regularly attained Controller chips available Lecture 37 Issues with this converter It’s a good converter for many applications requiring isolation. But… 1. Secondary-side diodes operate with zero-current switching. They require snubbing or other protection to avoid failure associated with avalanche breakdown 2. The resonant transitions reduce the effective duty cycle and conversion ratio. To compensate, the transformer turns ratio must be increased, leading to increased reflected load current in the primary-side elements 3. During the D’Ts interval when both output diodes conduct, inductor Lc stores energy (needed for ZVS to initiate the next DTs interval) and its current circulates around the primary-side elements—causing conduction loss ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 2 Lecture 37 Result of analysis Basic configuration: full bridge ZVT ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 3 Lecture 37 Actual waveforms, including resonant transitions ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 4 Lecture 37 Issues with this converter It’s a good converter for many applications requiring isolation. But… 1. Secondary-side diodes operate with zero-current switching. They require snubbing or other protection to avoid failure associated with avalanche breakdown 2. The resonant transitions reduce the effective duty cycle and conversion ratio. To compensate, the transformer turns ratio must be increased, leading to increased reflected load current in the primary-side elements 3. During the D’Ts interval when both output diodes conduct, inductor Lc stores energy (needed for ZVS to initiate the next DTs interval) and its current circulates around the primary-side elements—causing conduction loss ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 5 Lecture 37 Diode switching analysis ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 6 Lecture 37 Diode commutation: intervals 3 and 4 ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 7 Lecture 37 Waveforms: ZCS of D6 ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 8 Lecture 37 Intervals 3, 3', and 4' ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 9 Lecture 37 Simplification of circuit model during 4' ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 10 Lecture 37 Simplification of circuit model during 4' ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 11 Lecture 37 State plane diagram of ringing during 4' ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 12 Lecture 37 Waveforms: ZCS of D6 ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 13 Lecture 37 Approaches to snub the diode ringing (a) conventional diode snubber ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 14 Lecture 37 Approaches to snub the diode ringing (b) conventional passive voltage-clamp snubber ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 15 Lecture 37 Approaches to snub the diode ringing (c) simplify to one passive voltage-clamp snubber ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 16 Lecture 37 Approaches to snub the diode ringing (d) improvement of efficiency in voltage-clamp snubber ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 17 Lecture 37 Approaches to snub the diode ringing (e) active clamp lossless snubber ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 18 Lecture 37 Approaches to snub the diode ringing (f) primary-side lossless voltage clamp ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 19 Lecture 37 Another application of the ZVT: DC Transformer Operate at a fixed conversion ratio with high duty cycle, leading to high efficiency—avoids the problems of circulating currents Use other elements in the system to regulate voltage PFC 350 V ZVT 5V DC-DC 1V Load AC line isolation ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 20 DC-DC Load DC-DC Load Lecture 37 Active clamp circuits Can be viewed as a lossless voltage-clamp snubber that employs a current-bidirectional switch See Vinciarelli patent (1982) for use in forward converter Related to other half-bridge ZVS circuits Can be added to the transistor in any PWM converter Not only adds ZVS to forward converter, but also resets transformer better, leading to better transistor utilization than conventional reset circuit ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 21 Lecture 37 The conventional forward converter • Max vds = 2Vg + ringing • Limited to D < 0.5 • On-state transistor current is P/DVg • Magnetizing current must operate in DCM • Peak transistor voltage occurs during transformer reset • Could reset the transformer with less voltage if interval 3 were reduced ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 22 Lecture 37 The active-clamp forward converter • Better transistor/transformer utilization • ZVS • Not limited to D < 0.5 Transistors are driven in usual half-bridge manner: ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 23 Lecture 37 Approximate analysis: ignore resonant transitions, dead times, and resonant elements ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 24 Lecture 37 Charge balance Vb can be viewed as a flyback converter output. By use of a current-bidirectional switch, there is no DCM, and LM operates in CCM. ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 25 Lecture 37 Peak transistor voltage Max vds = Vg + Vb = Vg /D’ which is less than the conventional value of 2 Vg when D > 0.5 This can be used to considerable advantage in practical applications where there is a specified range of Vg ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 26 Lecture 37 Design example 270 V ≤ Vg ≤ 350 V max Pload = P = 200 W Compare designs using conventional 1:1 reset winding and using active clamp circuit ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 27 Lecture 37 Conventional case Peak vds = 2Vg + ringing = 700 V + ringing Let’s let max D = 0.5 (at Vg = 270 V), which is optimistic Then min D (at Vg = 350 V) is (0.5)(270)/(350) = 0.3857 The on-state transistor current, neglecting ripple, is given by ig = DnI = Did-on with P = 200 W = Vg ig = DVg id-on So id-on = P/DVg = (200W) / (0.5)(270 V) = 1.5 A ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 28 Lecture 37 Active clamp case: scenario #1 Suppose we choose the same turns ratio as in the conventional design. Then the converter operates with the same range of duty cycles, and the on-state transistor current is the same. But the transistor voltage is equal to Vg / D’, and is reduced: At Vg = 270 V: D = 0.5 peak vds = 540 V At Vg = 350 V: D = 0.3857 peak vds = 570 V which is considerably less than 700 V ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 29 Lecture 37 Active clamp case: scenario #2 Suppose we operate at a higher duty cycle, say, D = 0.5 at Vg = 350 V. Then the transistor voltage is equal to Vg / D’, and is similar to the conventional design under worst-case conditions: At Vg = 270 V: At Vg = 350 V: D = 0.648 D = 0.5 peak vds = 767 V peak vds = 700 V But we can use a lower turns ratio that leads to lower reflected current in Q1: id-on = P/DVg = (200W) / (0.5)(350 V) = 1.15 A ECEN 5817 Resonant and Soft-Switching Techniques in Power Electronics 30 Lecture 37