Megohmmeters 5kV C.A 6545 / C.A 6547 SALES PRODUCT INFORMATION Electrical testing and safety Cécile Le Goué PC_F_ CA 6545/47 - 1 Personal et confidential TEST & MEASUREMENT DIVISION The Experts in insulation at 5kV PC_F_ CA 6545/47 - 2 Personal et confidential TEST & MEASUREMENT DIVISION Measurements C.A 6545 C.A 6547 INSULATION Predetermined test voltages : 500-1000-2500-5000V Programmable test voltage : 40 à 5100V (pas 10V/100V) VOLTAGE 30 kW…10 TW 10 kW…10 TW 25…5100 V DC (15..500 Hz) CAPACITANCE 0,005…49,99 µF LEAKAGE CURRENT 0,000…3000 µA PC_F_ CA 6545/47 - 3 Personal et confidential TEST & MEASUREMENT DIVISION Functional specifications C.A 6545 Automatic calculation of DAR & PI ratios Automatic calculation of DD (Dielectric Discharge test) Yes, DAR & PI Yes, DD = I1mn / (Test voltage x C) Yes Programming of test duration R(t) function C.A 6547 Limited to 20 samples With 128 kbyte SMOOTH function Yes Programmable alarms Yes Exact test voltage measured Yes PC_F_ CA 6545/47 - 4 Personal et confidential TEST & MEASUREMENT DIVISION Other specifications C.A 6545 C.A 6547 Memory - Yes, with 128 kbyte RS232 - Yes, bi-directionnal Supply NiMH rechargeable battery Yes Battery charge status indicator Backlit screen + bargraph Electrical safety Dimensions Yes IEC 1010-1 Cat.III 1000V (or Ca.I 2500V) + EN 61557 270 x 250 x 180 mm 4 300 g Weight PC_F_ CA 6545/47 - 5 Personal et confidential TEST & MEASUREMENT DIVISION A special built-for-the-field design Clamps and plugs are perfectly insulated and measurement leads are 3m long. A 3m guard lead is also supplied for high-insulation measurements. A tool-bag containing all accessories A site-adapted hard casing, IP 67 when closed and IP 53 when opened PC_F_ CA 6545/47 - 6 Personal et confidential TEST & MEASUREMENT DIVISION A studied ergonomic design Test voltage selection by rotary switch: • 4 pre-determined test voltages: 500 V 1000V 2500V 5000V • 1 programmable test voltage position: 40 to 5100V in 10V or 100V steps Measurement and function selection by pressing on a push-button A giant backlit LCD screen with digital display + bargraph PC_F_ CA 6545/47 - 7 Personal et confidential TEST & MEASUREMENT DIVISION For an excellent quantitative analysis... INSULATION measurement to 10 TW VOLTAGE measurement to 5100 V CAPACITANCE measurement of the tested circuit LEAKAGE CURRENT measurement and qualitative analysis... automatic calculation of DAR, PI and DD ratios R(t) graph plotting PC_F_ CA 6545/47 - 8 Personal et confidential TEST & MEASUREMENT DIVISION Reminder Insulation resistance measurement qualifies the degree of insulation in installations or equipment. It also serves as a basis for preventive maintenance. Insulation measurement is very sensitive to variations in temperature and humidity. While testing, measurement is also initially influenced by unwanted currents. So, it is best to carry out : quantitative measurement of long duration: provided by mode "Time-controlled testing" and R(t) graph plotting a qualitative analysis with calculation of DAR, PI and DD ratios. PC_F_ CA 6545/47 - 9 Personal et confidential TEST & MEASUREMENT DIVISION Reminder * DAR, PI ? A qualitative analysis can turn out to be more clever and reliable than a simple quantitative analysis: the calculation of DAR and PI ratios enable the user to ignore climatic conditions and unwanted currents liable to invalidate measurement results. reminder : DAR = R 1mn / R 30s & PI = R 10mn / R 1mn * DD ? This test is especially suited for measurement on heterogeneous and multi-layer insulation, for it can reveal a defective layer among layers with high resistance. We recommend charging the insulator with 500V for 30 minutes. DD = I1mn (current measured after 1mn (mA)) Test voltage (Volt) x Capacitance measured (Farad) * R(t) graph plotting : when a time-controlled test begins, measured insulation samples are automatically memorized. It is possible to follow insulation evolution in function to the test voltage's application duration. Then R(t) graph can then be plotted out either by hand or directly on a PC screen using the MégohmView software. PC_F_ CA 6545/47 - 10 Personal et confidential TEST & MEASUREMENT DIVISION To order C.A 6545…………………………………………P01.1397.01 C.A 6547…………………………………………P01.1397.02 delivered complete with tool-bag containing accessories : - 2 x 3 m safety leads with HV plug and HV crocodile clip (red/blue) - 1 x 3 m safety guard lead with HV rear pick up plug and HV crocodile clip (black) - 1 x 0.35 m rear pick up lead (blue) - 1 x 2 m mains supply lead - 1 user's manual in 5 languages code 689 439 A00 - 5 plastic-coated, two-sided condensed user's manual PC_F_ CA 6545/47 - 11 Personal et confidential TEST & MEASUREMENT DIVISION Accessories & replacement parts 8 m HV blue crocodile clip lead 8 m HV red crocodile clip lead 8 m HV black crocodile clip rear pick up lead 15 m HV blue crocodile clip lead 15m HV red crocodile clip lead 15 m HV black crocodile clip rear pick up lead PC Software for C.A 6547 Serial printer Serial-to-parallel adapter 3 x 3m HV crocodile clip leads (blue / red / guarded black) 0.35 m rear pick up lead (blue) Tool-bag 2 m mains supply lead PC_F_ CA 6545/47 - 12 Personal et confidential TEST & MEASUREMENT DIVISION P01.2952.14 P01.2952.15 P01.2952.16 P01.2952.17 P01.2952.18 P01.2952.19 P01.1019.38A P01.1029.03 P01.1019.41 P01.2952.20 P01.2952.21 P01.2980.61 P01.2951.74