* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SF6 CB
Immunity-aware programming wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrification wikipedia , lookup
Electric power system wikipedia , lookup
Transformer wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Power inverter wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Fault tolerance wikipedia , lookup
Current source wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Voltage regulator wikipedia , lookup
Power electronics wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Transformer types wikipedia , lookup
Power engineering wikipedia , lookup
Distribution management system wikipedia , lookup
Ground (electricity) wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Surge protector wikipedia , lookup
Protective relay wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
History of electric power transmission wikipedia , lookup
Circuit breaker wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
SWITCHYARD www.powerpointpresentationon.blogspot.com What is a Switchyard ? It is a switching station which has the following credits : (i) Main link between Generating plant and Transmission system, which has a large influence on the security of the supply. (ii) Step-up and/or Step-down the voltage levels depending upon the Network Node. (iii) Switching ON/OFF Reactive Power Control devices, which has effect on Quality of power. SWITCHYARD EQUIPMENTS • Equipments commonly found in switchyard : 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Lightening arrestor Current transformer Voltage transformer Power transformers / I.C.T. Bus bar and clamp fittings Support structure Isolators Circuit Breaker Wave traps Earthing switch Functions of various equipment : * Transformers : - Transforms the voltage levels from higher to lower level or vice versa, keeping the power constant. * Circuit breakers : - Makes or automatically breaks the electrical circuits under Loaded condition. * Isolators : - Opens or closes the electrical circuits under No-load conditions. * Instrument transformers : - For stepping-down the electrical parameter (Voltage or Current) to a lower and safe value for Metering and Protection logics. * Earth switch : - Used to connect the charged body to ground to discharge the trapped charge to have a safe maintenance zone. Functions of various equipment : * Lightning arrestors : - Safe guards the equipment by discharging the high currents due to Lightning. * Overhead earth wire : - Protects the O/H transmission line from Lightning strokes. * Bus bar : - Conductors to which a number of circuits are connected. * Wave Traps/Line traps : - Used in PLCC circuits for Communication and Protection of Transmission lines * Reactive Power control devices : - Controls the reactive power imbalance in the grid by switching ON/OFF the Shunt Reactors, Shunt Capacitors etc., * Current Limiting Reactors : - Limits the Short circuit currents in case of faulty conditions. Switchyard One line Diagram Transfer Bus 400 KV Main Bus II Main Bus I Bus Isolator CB CB CB Transfer Bus Bay GT 20.5/400KV Gen Bay Feeder Bay Bus Switching Schemes : Bus Bar Schemes * Single Sectionalised bus * Main & Transfer bus * Sectionalised Main bus with Transfer bus * Sectionalised Double Main & Transfer bus Breaker Schemes * Ring bus * One and Half breaker * Double bus Double breaker * Single Sectionalized Bus-bar system : I/C Feeders CB Bus-bar Isolators O/G Feeders * Main & Transfer Bus-bar system : I/C Feeders CB Transfer Bus Bus Coupler Main Bus Isolators * Ring Bus system : Bus CB O/G feeder I/C Supply * One and Half Breaker scheme : Main 1 Main 2 Feeder 2 Tie CB Feeder 1 What is a Switchgear ? “The apparatus used for Switching, Controlling and Protecting the Electrical Circuits and equipment”. Need of Switchgear : * Switching during normal operating conditions for the purpose of Operation and Maintenance. * Switching during Faults and Abnormal conditions and interrupting the fault currents. Relays Relay : “A device that detects the fault and initiates the operation of the Circuit breaker to isolate the defective element from the rest of the system”. * The relays detect the abnormal conditions in the electrical circuits by constantly measuring the electrical quantities which are different under normal and faulty conditions. Requirements of Protecting relaying : Selectivity - Ability to select the faulty part and isolate that part without disturbing the rest of the system. Speed - Ability to disconnect the faulty part at the earliest possible time. Sensitivity - Ability of the relay to operate with low value of actuating quantity. Reliability - Ability of the system to operate under pre-determined conditions Simplicity - Should be so simple so that it can be easily maintained. - The simpler the protection scheme, the greater is the reliability Economy - Availability at lower cost. - Generally, the protective gear should not cost more than 10% of the total cost. However, when the apparatus to be protected is of utmost importance (e.g. Generator, GT etc) economic conditions are subordinated to reliability. Basic classification of Relays based on Function : * Over current * Under Voltage * Impedance * Under Frequency * Directional Circuit Breakers Main Parts of a Circuit Breaker : * Fixed Contact * Movable Contact * Operating Mechanism * Arc extinguishing medium Basic relay circuit scheme Equipment CT CB Supply from source RELAY Trip Coil of Breaker Battery Fault clearing process : During any Fault….. * Fault impedance will be low, so fault current will increase and relay senses this increase in current. * Relay contacts closes and sends trip signal to circuit breaker and the trip coil of the circuit breaker will get energized. * Operating mechanism of the circuit breaker will operate and separate the contacts. * Arc will be initiated between the contacts and it is extinguished by suitable methods. Arcing phenomenon : - When a fault occurs, heavy current flows through the contacts of the circuit breaker before they are opened by the protective system. - At the instant when the contacts begin to separate, the contact area decreases rapidly and current density (I/A) increases and hence rise in temperature. -The heat produced is sufficient to ionise the medium between the contacts. This ionised medium acts as conductor and an arc is struck between the contacts. - The potential difference between the contacts is very small and is sufficient to maintain the arc. - The current flow depends upon the Arc resistance. Few definitions : Breaking Capacity Max fault current at which a CB of breaking a circuit. is capable Making Capacity Max current a CB can withstand if it closing on existing Short circuit. Restriking Voltage –After the arc has been extinguished, the voltage across the breaker terminals does not normalize instantaneously but it oscillates The transient voltage which appears across the breaker contacts at the instant of arc being extinguished. Recovery Voltage –Power frequency voltage which appears across the breaker contacts after the arc is finally extinguished and transient oscillations die out. Events/Timings during fault clearing process : Fault clearing Time Relay time Circuit breaker Time = Relay time = Instant Of Fault = Closure of Trip Circuit + Circuit breaker Time to Closure of Trip Circuit to Final arc Extinction Various types of CBs : (i) Miniature CB (ii) Air Break CB (iii) Air Blast CB (iv) Oil CB (v) SF6 CB (vi) Vacuum CB Bulk Oil CB Minimum Oil CB Air Break CB : Air Blast CB : ABCB- Principle of arc quenching Bulk Oil CB : Minimum Oil CB : SF6 CB : 1. Op mechanism 8. Puffer cylinder 2. Interrupter 9. Nozzle 3. Support 10. Fixed position 4. Op rod 11. Fixed contact 5. Linkage 12. Moving contact 6. Terminals 13. Gas inlet 7. Filters Advantage of SF6 * Inert gas with high dielectric strength. * Colour less and odour less. * Non-toxic and non- inflammable. * Sf6 is blown axially to the arc, hence it removes the heat by axial convection and radial dissipation. As result the arc dia reduces and comes to zero at current zero. * Gas pressure in the chamber is at 5 ksc. * SF6 is filled at a pressure of 12 ksc in the tank and maintained by means of an individual or a common compressor. * The decomposition products of arcing are not explosive hence no chance of fire. Disadvantages * SF6 gas condensates at low temperature & high pressure Vacuum CB : Advantage of vacuum CB * Used up to 66 KV. * Vacuum is highly dielectric, so arc can’t persists. * Separation of contacts causes the release of metal vapour from the contacts, the density of vapour depends on the fault current. * At current zero the vapour emission will tends to zero and the density will becomes zero and dielectric strength will build up and restriking will be prevented. * No emission to atmosphere, hence pollution free. * Non- explosive and silent operation. * Compact size. Disadvantages * High initial cost. * Surge suppressors (R or RC combination) are to be connected at load side for limiting switching over-voltage while switching low pf loads. Isolator- functions Operates under off-load conditions Physically isolates the electric circuit Does not have any current making & breaking capacity Used in addition to C.B. Earth-Switch Operated when Isolator is open. Connected between Line conductor and Earth whenever required. Discharge the voltage trap in line. Isolator Isolator CB Source Earth S/W * Practically, Pantograph type Earth switches were used. Load Current transformers Purpose : - To step-down the high magnitude of current to a safe value to incorporate Measuring and Protection logics • Current transformers are used for the instrumentation, protection or metering of power systems and are normally installed on each side of a circuit breaker. Voltage transformers Purpose : - To step-down the high magnitude of voltage to a safe value to incorporate Measuring and Protection logics. • Voltage transformers serve a number of functions in a power system. They are required for the operation of many types of instrumentation and relay protective systems. They measure voltage and in conjunction with CT , they measure power. They feed synchronizing equipment. They can be used as coupling capacitors in power line carrier network. CAPACITIVE VOLTAGE TRANSFORMER • - Primary voltage is applied to a series of capacitors group. The voltage across one of the capacitor is taken to aux PT. The secondary of the aux PT is taken for measurement and protection. • SECONDARY VOLTAGES(110 VOLTS AC) FOR METERS AND ENERGY METERS • VOLTAGES FOR PROTECTIVE RELAYS • VOLTAGES FOR SYNCHRONIZING • DISTURBANCE RECORDERS AND EVENT LOGS • OVERFLUX RELAYS • PLCC Lightening Arrestor Purpose : - To discharge the high voltage surges in the power system due to lightning to the ground. Apparatus to be protected : * Overhead lines………Earth/Ground wires (PA=30 deg) * HV equipment………LAs * Substation…………...Lightning Masts, Earth wires Types : Rod gap LA : * Gap length is such that the break-down occurs at 80% of the spark voltage * After the surge, the arc in the gap is maintained by the normal supply voltage. So, only used as a back-up. Insulator Rod gap Equipment body Wave Trap Transmission Line S/S-1 Wave Trap To control room of S/S-1 S/S-2 Wave Trap To control room of S/S-2 * Wave trap is used for Protection of the transmission line and communication between the Substations. * VHF signal is transmitted from one end to the another through the same power line. * Sends inter-trip signal to the other end CBs so that fault can be isolated at the earliest time. THANK YOU