Download PTQ-‐104S - ProSoft Technology

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Quantum dot wikipedia , lookup

Many-worlds interpretation wikipedia , lookup

Orchestrated objective reduction wikipedia , lookup

Symmetry in quantum mechanics wikipedia , lookup

Quantum fiction wikipedia , lookup

Quantum computing wikipedia , lookup

EPR paradox wikipedia , lookup

Interpretations of quantum mechanics wikipedia , lookup

History of quantum field theory wikipedia , lookup

Quantum teleportation wikipedia , lookup

Canonical quantization wikipedia , lookup

Quantum key distribution wikipedia , lookup

T-symmetry wikipedia , lookup

Quantum machine learning wikipedia , lookup

Quantum state wikipedia , lookup

Hidden variable theory wikipedia , lookup

Quantum group wikipedia , lookup

Transcript
 PTQ-­‐104S What applications can I use the PTQ-­‐104S module for? The PTQ-104S module is used to place a Schneider Electric Quantum processor on an IEC
60870-5-104 communications network, passing data to/from the Quantum processor up to a
SCADA or DCS system.
Is the PTQ-­‐104S module supported in Hot-­‐Standby applications? Yes, with the latest version of the firmware for the PTQ-104S (version 2.05 and above), the
module is now able to operate in a Quantum Unity Hot-Standby application. As the
Quantum system changes from secondary to primary, the PTQ-104S changes it's IP address
and allows communications to the SCADA or DCS host to continue to occur.
Is the PTQ-­‐104S version 2 module compatible with previous v1 units ? No, the PTQ-104S module version 2.05 and greater is not backwards compatible with
previous PTQ-104S version 1 units. To support the HSBY architecture, we needed to have
a contiguous block of memory that the module exchanged data with the processor. This
meant that the backplane data exchanges had to be configured differently between v2 and
previously released v1 modules.
Version 2 units can be firmware downgraded to version 1 by contacting technical support,
but all new functionality will be added to the version 2 modules.
What programming environments is the module supported in? For Hot-Standby systems the module is only supported with the Unity Pro software
environment. If HSBY is not to be used, the module can support Concept, ProWORX
NxT, ProWORX 32, and even Modsoft .
How many PTQ modules can be used in a Quantum system? With the current version of Unity Pro, up to 5 ProSoft PTQ modules can communicate to a
single Quantum CPU.
Can I remotely connect to the module for configuration/diagnostics? Yes, the module allows for a remote connection via Ethernet to the module using the
supplied Windows software "ProSoft Configuration Builder." This software is used to
configure the PTQ module, what data is exchanged with the Quantum CPU, as well as what
devices the module will communicate with on the IEC 60870-5-104 network.
Diagnostic counters and status information is also available using the same ProSoft
Configuration Builder software.