* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SW560 Single Pole Single Throw Normally Open (Part of
Electrical substation wikipedia , lookup
Skin effect wikipedia , lookup
Wireless power transfer wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power engineering wikipedia , lookup
Electrical ballast wikipedia , lookup
Thermal runaway wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Electric machine wikipedia , lookup
History of electric power transmission wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Stepper motor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Capacitor discharge ignition wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Stray voltage wikipedia , lookup
Current source wikipedia , lookup
Surge protector wikipedia , lookup
Magnetic core wikipedia , lookup
Mains electricity wikipedia , lookup
Opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Distribution management system wikipedia , lookup
Alternating current wikipedia , lookup
Ignition system wikipedia , lookup
SW560 Single Pole Single Throw Normally Open (Part of the Busbar Series) The SW560 is designed for use in telecommunication and power distribution applications where an uninterrupted load is switched. These contactors are primarily for use with Direct Current loads but can also be used with Alternating Currents. • Uninterrupted current - no or infrequent load switching requirements (maintains lower contact resistance). Application The SW560 features double breaking main contacts with silver alloy tips which are weld resistant, hard wearing and have excellent conductivity. Silver plating on the main contacts is standard for the SW560 however, optionally it can be excluded from the specification. This compact contactor can be busbar mounted vertically or horizontally, but if mounted vertically, the coil should be at the bottom. If the coil is required at the top, we can adjust the contactor to compensate for this. Optional extras include auxiliary switches, brackets, coil finishes and magnetic latching which allows the contactor to remain closed while consuming no coil power. Uninterrupted Thermal Current Rating (Ith) 600A Intermittent Current Rating: 30% Duty 1095A 40% Duty 950A 50% Duty 850A 60% Duty 775A 70% Duty 715A Rated Fault Current Breaking Capacity (Icn) Resistive Load: (in accordance with UL508*) SW560 900A at 60V D.C. SW560A Maximum Recommended Contact Voltages (Ue): SW560 Dimensions in mm [inches] 60V D.C. Typical Voltage Drop per pole across New Contacts at 100A <50mV Mechanical M.T.B.F >1 x 106 Coil Voltage Available (Us) (Rectifier board required for A.C.) From 6 to 240V A.C./D.C. Coil Power Dissipation: Highly Intermittent Rated Types 40 - 50 Watts Intermittently Rated Types 30 - 40 Watts Prolonged Rated Types 15 - 30 Watts Continuously Rated Types 10 - 15 Watts Maximum Pull-In Voltage (Coil at 20˚ C) Guideline: Highly Intermittent Rated types (Max 25% Duty Cycle) 60% Us Intermittently Rated types (Max 70% Duty Cycle) 60% Us Prolonged Operation (Max 90% Duty Cycle) 60% Us Continuously Rated Types (100% Duty Cycle) 66% Us Drop-Out Voltage Range 10 - 30% Us Typical Pull-In Time 30ms Typical Drop-Out Time (N/O Contacts to Open): Without Suppression 8ms With Diode Suppression 60ms With Diode and Resistor (Subject to resistance value) 25ms 900 Typical Contact Bounce Period < 5ms 800 Operating Ambient Temperature - 40˚C to + 60˚C 700 Magnetic Latching† (Not fail safe) ○ 100 Closed Contact Housing X Environmentally Protected IP66 X EE Type (Steel Shroud) X 2A at 48V D.C. Contact Performance Key: Copper busbar Cable Key: 387mm2 [0.6inch2] Uninterrupted Current Rated suitable for Application = Uninterrupted Note: Where applicable values shown are at 20˚C * Please check our web site for product UL status • • • • v3-04-13 Performance data provided should be used as a guide only. Some de-rating or variation from figures may be necessary according to application. Thermal current ratings stated are dependant upon the size of conductor being used For further technical advice email: [email protected] Albright reserve the right to change data without prior notice 00 25 22 50 00 20 Current (Amperes) 0.5A at 240V D.C. Advised Connection Sizes for Maximum Continuous Current 17 50 0 00 0 SW560C 5A at 24V D.C. 200 15 SW560A X 300 50 Auxiliary Contact Switching Capabilities (Resistive Load): X X 12 5A Magnetic Blowouts† Magnetic Blowouts - High Powered† ○ 00 Auxiliary Thermal Current Rating Auxiliary Contacts - V3 Mounting Brackets (see Busbar Series Catalogue) 400 0 Auxiliary Details Suffix ○ ○ Armature Cap 10 + 20 gms 500 75 With Auxiliary Figures are for guideline purposes only 600 0 1100 gms General Auxiliary Contacts 50 Time (Seconds) Guideline Contactor Weight: SW560 SW560 Available Options SW560 Contactor Performance M Contacts Connection Diagram SW560A A C SW560C Large Tips X Textured Tips X Silver Plating (fitted as standard) ○ Coil Manual Override Operation ○ ○ ○ ○ M4 Stud Terminals X AC Rectifier Board (Fitted) Coil Suppression† Flying Leads M5 Terminal Board X Vacuum Impregnation ○ Key: Optional † ○ Standard ● F Not Available X Connections become polarity sensitive Albright International Ltd, Evingar Trading Estate, Ardglen Road, Whitchurch, Hampshire, RG28 UK20 8390 1927 Albright International, 125 Red Lion Road, Surbiton, Surrey KT6 7QS, England,Tel: +44 (0) 20 8390 5357, Fax:7BB, +44 (0) Tel: +44 (0)1256 893060, Fax: +44 (0)1256 893562, Dedicated Sales Tel: +44 (0)1256 890030, Fax: +44 (0)1256 890043 E-mail: [email protected] or [email protected] Web Site: www.albrightinternational.com E-mail: [email protected] or [email protected] Web Site: www.albrightinternational.com Copyright © 2010 Albright International Ltd Copyright © 2013 Albright International LTD SW560