American Industrial Supply
Inc. DATA SHEET
TECHNICAL
aIs
DEVOUR
"New Generation"
Liquid Alive Bacteria
Free Enzyme Cultures
ES
AST
CW
I
N
A
ORG TLY
ALL NSTAN
S
E
I
I
UEF DORS REE TING SAFE
LIQ
O
S & FOUL ELLA F-POLLU TALLY
T
S
E TES MON
N
EN
G
I
• D MINA SAL C • NO IRONM ALINE
I
I
V
D
K
L
N
• E TIFIE NOGE D • EN N-AL
R
O
• CE N-PATH ORIZE XIC, N
H
O
• NO A AUT NON-T
D
,
• US N-ACID
• NO
Product # 3047 Quarts
Product # 5169 Bulk
For Professional Use Only
Contains no hazardous ingredients as listed in the
following references: (1) CFR 29, 1910.1000, subpart Z,
REV 01JUL88; (2) The Director's List of Hazardous
Substances (CA); (3) Threshold Limit Values and Biological
Exposure indices for 1989-1990 (ACGIH)
0
0
0
Lateral Diameters (Inches)
8 inches
12 inches
16 inches
20 inches
24 inches
Ounces/500 feet
32 ounces
48 ounces
64 ounces
96 ounces
128 ounces
Additional Information
Aerobic bacteria ........................50 million/ml
Anaerobic Bacteria ...................50 million/ml
Total Bacterial..........................100 million/ml
Protease Enzyme...............2500 PV units/ml
Amylase Enzyme.................300 DV units/ml
Lipase Enzyme ................................Present
Form ...................................................Liquid
Color...............................Light Lemon Yellow
Odor.....................................................Slight
Flash Point (ASTM-D3278)...................None
Storage Stability at 70° F.....................1 year
Phosphates (as % P2O5)........................O%
DEVOUR combines the synergistic power of FREE
ENZYMES and specially cultured bacteria this liquid
has tremendous waste-digesting power in a convenient
liquid form. It introduces millions of beneficial bacteria
to digest waste and eliminate odors in plumbing,
grease traps, septic systems and all other waste
systems. This product contains bacterial spores - no
vegetative cells that might cause spoilage - and high
level of free enzymes to provide the most effective
action. DEVOUR contains no solvents, acids, or
caustics and will not harm any type of plumbing.
Eliminate odors and waste the natural way!
SPECIFICATIONS: these specifications are typical and subject to
usual manufacturing tolerances.
Corporate Office
Burbank, California
To Order Call (800) 366-0961
aIs
D
E
V
O
U
R
NATIONWIDE DISTRIBUTION
• Burbank • Atlanta
• Philadelphia • Houston
CONSULT LABEL AND MSDS BEFORE USING.
HEALTH
FLAMMABILITY
REACTIVITY
SPECIFIC
DEVOUR New Generation, combines the potent waste
digesting properties of natural enzymes and special strains of
natural bacteria. These Bacillus bacteria spores (both
anaerobic and aerobic) are cultured for the ability to digest
waste in minutes, not hours as most.
DEVOUR New
Generation’s bacteria are combined with FREE ENZYMES
using a patented stabilization process. Enzymes work as predigesters to break down solid wastes, paper, grease, oils and
fats. Bacteria then digests waste - just as in lakes, streams and
rivers.
APPLICATIONS FOR DEVOUR:
SINKS, FLOOR DRAINS, URINALS AND TOILETS: Use 2
ounces once per week in every drain and allow to work
overnight. For drains that receive large amounts of organic
matter (kitchen and floor drains, laundry sinks and drains),
increase the treatment to 4 to 6 ounces, as often as every other
day. For best results, add digestant at end of day or other period
of lowest flow. Bleach, disinfectants and harsh drain openers
may kill the bacteria. Allow several hours after the use of these
products, then re-treat with digestant. GREASE TRAPS: For
average size grease traps (about 20 cubic feet), use one quart
added directly to trap or through drain. Then use one pint per
week for maintenance.
SEPTIC TANKS: Use 2 to 4 quarts for initial treatment of 500
gallon tank. For weekly maintenance, use 1 pint for each 5
people on the the system. Treat drain fields and leach beds by
pouring into the distribution boxes or vents.
SEWER LATERALS: Laterals are treated during periods of low
flow by adding through manholes. Dosage per unit length of
lateral will vary with the diameter of the line: