Noninvasive central blood pressure assessment
The SphygmoCor CP System
®
The gold standard in noninvasive central blood pressure assessment
SphygmoCor technology is the gold standard for noninvasive measurement of central blood pressure.
It is fully validated and has been featured in hundreds of published clinical studies. It is used in
leading medical centers worldwide and in pharmaceutical clinical trials.
The SphygmoCor CP system
acquires the patient’s radial pulse
waveform noninvasively by
applanation tonometry, derives the
pressure waveform of the ascending
aorta and reports vital
central blood pressure data.
Features
Benefits
Instantaneous calculation of key parameters,
including
– Central pressure has been shown to be a superior,
independent predictor of future cardiovascular
events than peripheral pressure
– Central Pressure Waveform
– Aortic Pulse Pressure
– Aortic Systolic Pressure
– Aortic Augmentation Index
– Ejection Duration
– Allows assessment of drug effects that cannot be
detected with brachial pressure measurements
– Provides patients with visual evidence of the effects
of lifestyle changes and drug therapies
Automatic, real-time QA feedback leading to
minimal operator variability
Noninvasive test, comfortable for patients, no
disposables needed
www.atcormedical.com
System
Specifications
SphygmoCor ® CP
System
SYSTEM SPECIFICATION
Product Configuration
PC Interface Specifications
PRODUCT
INPUTS
#V-3#0
4ONOMETER
SPECIFICATION
Physical and Environmental Specifications
/PERATING!MBIENTTEMPERATURE
ª#TOª#ª&TOª&
/PERATING2ELATIVEHUMIDITY
TO
0OWERSUPPLY53"POWERED
3UPPLY6OLTAGE
0OWER#ONSUMPTION
0ROTECTIVE#LASS
!PPLIED0ARTS
0OWER#ONNECTOR
53"6$#
M!MAX
)%##LASS)))OR)NTERNALLY
POWEREDDEPENDSON#OMPUTER
THATMODULEISCONNECTEDTO
4YPE#&%#'
4YPE"&4ONOMETER
6IA53"4YPE!#ONNECTOR
0HYSICAL3PECIlCATIONS
%NCLOSURE-ATERIAL
7EIGHT-ODULE4ONOMETER
$IMENSIONS
0#!"3
KGLBS
LXWXHCM
vLXvWXvH
Minimum Computer Requirements
IBM compatible PC or notebook computer with:
s0ENTIUM0ROCESSOR0ORGREATER
s'"2!-
sXCOLOUR8'!DISPLAY
s'"INITIALFREEHARDDISCSPACE
s#$2/-DRIVE
s7INDOWSSTANDARDPRINTERDRIVERS
s$EDICATED53"PORT
s7INDOWS800RO80"USINESS
6ISTA"USINESSOR6ISTA5LTIMATEONLY
s4HE3PHYGMO#OR®%-ISNOTSUPPORTEDON
7INDOWS.4-%
5NICATION)NTERFACE
53"SERIALINTERFACE
53"4YPE"&EMALECONNECTOR
Regulatory
Input Signal Specifications
INPUT
SPECIFICATION
FDA clearance
4ONOMETER
$IFFUSEDSEMICONDUCTORWHETSTONEBRIDGESENSOR
3ENSITIVITY
«66MM(G
#ONTACT0RESSURE2ANGE
nMM(G
#ALIBRATION
5NCALIBRATEDCALIBRATEMANUALLY
WITHSPHYGMOMANOMETER
2EFERENCE0RESSURE
!TMOSPHERE
"ANDWIDTH
$#n(Z
3AMPLING2ATE
(Z
'AIN/FFSET!DJUST
!UTO
3IGNAL2ANGE!CCURACY
M6¢
EU CE Mark (MDD, ANNEX II, Class IIa)
MHLW, Japan
&OOTSWITCH
4YPE
)02ATING
www.atcormedical.com
TGA, Australia
IEC 60601-1/ AS/NZS 3200.1 (amendments 1 and 2)
Electromedical Equipment Safety standard
IEC 60601-1-2 Electro-Medical Equipment, Electro Magnetic
Compliance (EMC) Standard
-ICROSWITCH
)08M
Noninvasive central blood pressure assessment