Noninvasive central blood pressure assessment The SphygmoCor CP System ® The gold standard in noninvasive central blood pressure assessment SphygmoCor technology is the gold standard for noninvasive measurement of central blood pressure. It is fully validated and has been featured in hundreds of published clinical studies. It is used in leading medical centers worldwide and in pharmaceutical clinical trials. The SphygmoCor CP system acquires the patient’s radial pulse waveform noninvasively by applanation tonometry, derives the pressure waveform of the ascending aorta and reports vital central blood pressure data. Features Benefits Instantaneous calculation of key parameters, including – Central pressure has been shown to be a superior, independent predictor of future cardiovascular events than peripheral pressure – Central Pressure Waveform – Aortic Pulse Pressure – Aortic Systolic Pressure – Aortic Augmentation Index – Ejection Duration – Allows assessment of drug effects that cannot be detected with brachial pressure measurements – Provides patients with visual evidence of the effects of lifestyle changes and drug therapies Automatic, real-time QA feedback leading to minimal operator variability Noninvasive test, comfortable for patients, no disposables needed www.atcormedical.com System Specifications SphygmoCor ® CP System SYSTEM SPECIFICATION Product Configuration PC Interface Specifications PRODUCT INPUTS #V-3#0 4ONOMETER SPECIFICATION Physical and Environmental Specifications /PERATING!MBIENTTEMPERATURE ª#TOª#ª&TOª& /PERATING2ELATIVEHUMIDITY TO 0OWERSUPPLY53"POWERED 3UPPLY6OLTAGE 0OWER#ONSUMPTION 0ROTECTIVE#LASS !PPLIED0ARTS 0OWER#ONNECTOR 53"6$# M!MAX )%##LASS)))OR)NTERNALLY POWEREDDEPENDSON#OMPUTER THATMODULEISCONNECTEDTO 4YPE#&%#' 4YPE"&4ONOMETER 6IA53"4YPE!#ONNECTOR 0HYSICAL3PECIlCATIONS %NCLOSURE-ATERIAL 7EIGHT-ODULE4ONOMETER $IMENSIONS 0#!"3 KGLBS LXWXHCM vLXvWXvH Minimum Computer Requirements IBM compatible PC or notebook computer with: s0ENTIUM0ROCESSOR0ORGREATER s'"2!- sXCOLOUR8'!DISPLAY s'"INITIALFREEHARDDISCSPACE s#$2/-DRIVE s7INDOWSSTANDARDPRINTERDRIVERS s$EDICATED53"PORT s7INDOWS800RO80"USINESS 6ISTA"USINESSOR6ISTA5LTIMATEONLY s4HE3PHYGMO#OR®%-ISNOTSUPPORTEDON 7INDOWS.4-% 5NICATION)NTERFACE 53"SERIALINTERFACE 53"4YPE"&EMALECONNECTOR Regulatory Input Signal Specifications INPUT SPECIFICATION FDA clearance 4ONOMETER $IFFUSEDSEMICONDUCTORWHETSTONEBRIDGESENSOR 3ENSITIVITY «66MM(G #ONTACT0RESSURE2ANGE nMM(G #ALIBRATION 5NCALIBRATEDCALIBRATEMANUALLY WITHSPHYGMOMANOMETER 2EFERENCE0RESSURE !TMOSPHERE "ANDWIDTH $#n(Z 3AMPLING2ATE (Z 'AIN/FFSET!DJUST !UTO 3IGNAL2ANGE!CCURACY M6¢ EU CE Mark (MDD, ANNEX II, Class IIa) MHLW, Japan &OOTSWITCH 4YPE )02ATING www.atcormedical.com TGA, Australia IEC 60601-1/ AS/NZS 3200.1 (amendments 1 and 2) Electromedical Equipment Safety standard IEC 60601-1-2 Electro-Medical Equipment, Electro Magnetic Compliance (EMC) Standard -ICROSWITCH )08M Noninvasive central blood pressure assessment