* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Just What Is A Service Factor?
Survey
Document related concepts
Switched-mode power supply wikipedia , lookup
Power factor wikipedia , lookup
Three-phase electric power wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Electrification wikipedia , lookup
Electric motor wikipedia , lookup
Voltage optimisation wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Induction motor wikipedia , lookup
Transcript
Just What Is A Service Factor? This is a question we regularly receive on the Hotline. Understanding how the service factor affects an electric motor can be confusing, but it is not as complicated as it may seem. This guide should help explain the term service factor and its relationship to Boat Hoist and Lift motors. The National Electrical Manufacturers Association (NEMA) defines service factor in section MG1 - 1.43 of their manual as: "The service factor of an alternating current (AC) motor is a multiplier which, when applied to the rated horsepower, indicates a permissible horsepower loading which may be carried under the conditions specified for the service factor." The conditions under which service factor may be applied are described in NEMA MG1 - 14.36 as: "When the voltage and frequency are maintained at the value specified on the motor's nameplate, the motor may be overloaded up to the horsepower obtained by multiplying the rated horsepower by the service factor shown on the nameplate." How does Service Factor (S.F.) Apply To A Motor? KNOW BEFORE YOU BUY! To determine the service factor horsepower of a motor, multiply Marathon 3/4 HP Boat Hoist Motors the nameplate horsepower (not amperage) by the service factor. HP= .75 For example, if a 1 Hp motor has a service factor of 1.25, the motor's service factor maximum horsepower is: (1 HP) x (1.25 S.F.) = 1.25 Hp SF = 1.00 Actual HP = .75 Leeson 3/4 HP Boat Hoist Motors HP= .75 SF = 1.25 Actual HP = .93 STRONGEST! AO SMITH 3/4 HP Boat Hoist Motors HP= .75 SF = 1.00 Actual HP = .75 Marathon 1 HP Boat Hoist Motors HP = 1hp SF = 1.25 Actual HP = 1.25 STRONGEST! Leeson 1 HP Boat Hoist Motors HP = 1hp SF = 1.00 Actual HP = 1.00 Anystandard 1 HP Boat Hoist Motors AO SMITH How Does Service Factor Relate to Motor Amps? HP = 1hp SF = 1.00 Actual HP = 1.00 Boat Hoist motors typically show two amperage values on the nameplate and in the specification sections of the equipment guide. The first value labeled "amps" is the expected running amps when the motor is operated at rated voltage and nameplate horsepower loads. The second value labeled "SF Amps" is the expected running amps when the motor is operated at rated voltage and service factor horsepower loads. Even though amps may increase slightly when input voltage is higher or lower than nameplate voltage, the motor amp reading remains the simplest indicator of motor load. your motor amp reading is higher than nameplate service factor amps, the horsepower load probably exceeds the service factor horsepower rating. If the AMPs are higher, continued use of the motor will cause permanent damage to the motor. Review the equipment guide for possible trouble shooting.