* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Sunmax installation manual
Resistive opto-isolator wikipedia , lookup
Music technology (electronic and digital) wikipedia , lookup
Schmitt trigger wikipedia , lookup
Opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Surge protector wikipedia , lookup
Power MOSFET wikipedia , lookup
Two-port network wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electronic paper wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Grid-connected PV Inverter Installation Guide Sunmax 1500 (Sunmax 1500-AU) Sunmax 2000 (Sunmax 2000-AU) Sunmax 2500 (Sunmax 2500-AU) Sunmax 3000 (Sunmax 3000-AU) Sunmax 3600 (Sunmax 3600-AU) Sunmax 4000 (Sunmax 4000-AU) Sunmax 4600 (Sunmax 4600-AU) Sunmax 5000 (Sunmax 5000-AU) SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 1 Notes on this Manual .................................................... 3 1.1 Validity ................................................................................................................................ 3 1.2 Installation Personnel .......................................................................................................... 3 1.3 Archiving of this Manual .................................................................................................... 3 1.4 Additional Information ........................................................................................................ 3 1.5 Symbols Used ..................................................................................................................... 3 2 Safety .................................................................. 4 2.1 Appropriate Usage ............................................................................................................... 4 2.2 Safety Instructions ............................................................................................................... 6 3 Unpacking ............................................................... 7 3.1 Products and Accessories .................................................................................................... 7 3.2 Examination for Damage during Transportation ................................................................. 8 3.3 Identify Sunmax .................................................................................................................. 8 4 Equipment Installation .................................................. 9 4.1 Select the Installation Position ............................................................................................ 9 4.1.1 Dimension and Weight ............................................................................................. 9 4.1.2 Ambient Environment .............................................................................................. 9 4.1.3 Safety Clearance ..................................................................................................... 10 4.1.4 Position for Keeping............................................................................................... 10 4.2 Instructions for Installation ............................................................................................... 11 4.2.1 Installation with Rack............................................................................................. 11 5 Electrical Connection .................................................. 12 5.1 Electrical Connection System Diagram ............................................................................ 12 5.2 Connection to Grid ............................................................................................................ 13 5.3 Connection of the AC Terminal......................................................................................... 15 5.3.1 Connection of Sunmax1500/2000/2000-AU .......................................................... 15 5.3.2 Connection of Sunmax 2500/2500-AU/3000/3000-AU ......................................... 15 5.3.3 Connection of Sunmax 3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU ..................................... 16 5.3.4 Steps for DC Terminal’s Connection ...................................................................... 16 5.4 Starting Steps of Sunmax .................................................................................................. 18 5.5 Stoppage of the Inverter .................................................................................................... 18 6 Setting the Country-specific Parameters ................................. 19 7 Communication .......................................................... 19 7.1 Communication Ports ........................................................................................................ 19 8 System Operation ....................................................... 20 9 Opening and Closing .................................................... 23 9.1 Opening Sunmax Housing ................................................................................................ 23 9.2 Closing Sunmax Housing .................................................................................................. 24 10 Troubleshooting and Maintenance ........................................ 25 10.1 Troubleshooting............................................................................................................... 25 10.2 Maintenance .................................................................................................................... 26 11 Contact us ............................................................ 27 2 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 1 Notes on this Manual 1.1 Validity This guide is applicable to eight models comprising Sunmax1500, Sunmax 1500-AU, Sunmax 2000,Sunmax 2000-AU, Sunmax 2500*,Sunmax 2500-AU, Sunmax 3000,Sunmax 3000-AU, Sunmax 3600*,Sunmax 3600-AU, Sunmax 4000,Sunmax 4000-AU, Sunmax 4600,Sunmax 4600-AU, Sunmax 5000,Sunmax 5000-AU. Note: * represents that this model is applicable to UK and Australia market only. 1.2 Installation Personnel The tasks described in this manual may be performed by electrically qualified persons only. 1.3 Archiving of this Manual The Installation Guide of Sunmax PV Grid-connected Inverter, and KLNE Warranty Card should be stored in a unified manner so as to provide you the most comprehensive assistance and the services with the highest quality. 1.4 Additional Information You can download the related information from the website www.kinglongpower.com, for example, you can download the supporting software related to your model. 1.5 Symbols Used The security warning symbols and explanations are as follows: 3 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD To avoid the risks of injury or damage to people or properties, users and operators must carefully read the safety instruction and warning information so as to ensure the proper installation and normal operation of the inverter. DANGER! ! “DANGER” indicates a hazardous situation which, if not avoided, will directly result in death or serious injury. WARNING! ! ! ! i "WARNING" indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION! "CAUTION" indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. ATTENTION! “ATTENTION” indicates a situation that can result in property damage if not avoided. The above are the signs and symbols used in this manual, which will be beneficial to you. 2 Safety 2.1 Appropriate Usage Grid-connected PV power systems consist of the photovoltaic array, a grid-connected inverter, metering device and power distribution system. Solar energy can be converted to DC energy through the solar cell array, and then convert the DC power energy to AC of same frequency and same voltage with the grid through the grid inverter. It is then fed into the power grid. The grid-connected PV inverter is the key piece of equipment in the photovoltaic power generation system. The Sunmax PV system configuration diagram is as follows: 4 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Note: If the Sunmax’s output terminal is only connected to the home load, Sunmax will stop working; Sunmax’s output must be connected to the grid or in parallel with the loads, and then connected to the grid. When designing this PV system, ensure that all the supporting equipment parameters except for Sunmax should always conform to the normal operating scope of Sunmax. Please refer to the technical parameter sheet in the appendix of this manual. Users must ensure that the data given by the photovoltaic panel array manufacturers is authentic and valid. Do not use the inverter for purposes other than those described here. The amendments to Sunmax clauses or the installation of parts, as well as Sunmax technological process and warranty claims, operating license, etc are not specially described. Relevant Certifications of Sunmax Sunmax 1500, Sunmax 1500-AU, Sunmax 2000, Sunmax 2000-AU, Sunmax 2500*, Sunmax 2500-AU*, Sunmax 3000, Sunmax 3000-AU, Sunmax 3600*,Sunmax 3600*-AU, Sunmax 4000,Sunmax 4000-AU, Sunmax 4600,Sunmax 4600-AU, Sunmax 5000, Sunmax 5000-AU Sunmax have passed the following certification standards. CE(VDE 0126-1-1, EN62109-1/-2) AS 4777&AS 3100 5 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD G83&G59 EMC(EN 61000-6-3; EN 61000-6-1; EN 61000-3-12; EN 61000-3-11) In accordance with the requirements of clients in different countries and different installation locations, Sunmax is able to set its network parameters to conform to the local grid connection regulations. 2.2 Safety Instructions Incorrect operations or mistaken use may cause danger: The life and health of operators or the third party; Equipment and other tangible property of the owner/operator; Working efficiency of equipment; Service life of equipment. ! DANGER! Danger of life due to high voltages in Sunmax! All work on the Sunmax must only be carried out by a qualified electrician. CAUTION! ! Danger of burn injuries due to hot housing parts! During operation, the upper cover of the housing and the housing body may become hot. ! CAUTION! Possible health risks due to the effects of radiation! Do not remain within a distance of less than 20 cm from the Sunmax for long periods of time. Grounding of PV panels i The grounding of panels should comply with the local requirements. To protect the properties and personal safety to the greatest extent, KLNE recommends that the external frame of the panel array should be grounded when the inverter is connected to it. 6 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 3 Unpacking 3.1 Products and Accessories Sunmax Accessory Bag Sealing Plug Item Product description and quantity Inverter One unit of Sunmax Sunmax 1500/1500-AU/2000/2000-AU/2500/2500-AU/3000/3000-AU, No sealing Plug Accessory bag Sunmax3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU , 2 sets of sealing plugs 1 AC terminal, 2 waterproof connectors, 4 expansion bolts, 4 self tapping screws, 4 ∅5 cap flanges, 2 stainless steel bolts(M5*8) and 2 stainless steel bolts (M6*14); Installation bracket 1 installation bracket Handbook 1 installation manual, 1 warranty card and 1 sheet of technical parameters. 7 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Role of the Sealing Plug After installation, block the terminal port with a sealing plug to prevent the water vapor from accessing the Sunmax and affecting the service life. 3.2 Examination for Damage during Transportation The inverter has been inspected before packaging and transportation. Although the product’s packaging is firm, unpredictable damages may occur due to accidents in the transportation process. When delivery, please carefully check the product’s packaging and internal parts such as housing, display screen, DC terminals and so on. If you find any damages, please record them in the form of a picture and contact your distributors. 3.3 Identify Sunmax You must confirm the trademark of Sunmax and the trademark is put at the display screen of the housing. Display screen of Sunmax Parameter Nameplate of Sunmax 1500 Parameter Nameplate of Sunmax 1500-AU 8 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 4 Equipment Installation 4.1 Select the Installation Position ! WARNING! Danger to life due to fire or explosion! The Sunmax housing can become hot during operation. ! Do not mount the Sunmax on flammable construction materials. Do not mount the Sunmax in areas where highly flammable materials are stored. Do not mount the Sunmax in areas where there is a risk of explosion. CAUTION! Danger of burn injuries due to hot housing parts! Mount the Sunmax such that it cannot be touched inadvertently. 4.1.1 Dimension and Weight Sunmax 1500/1500-AU/2000/2000-AU/ 2500/2500-AU/3000/3000-AU/:14kg Sunmax3600/3600-AU/4000/4000-AU/ 4600/4600-AU/5000/5000-AU: 18.4kg 4.1.2 Ambient Environment The protection level of Sunmax is IP65. The inverter can be placed outdoors. The installation location should be kept clean. When choosing Sunmax’s installation position and method, its weight and size should be taken into consideration; 9 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Make sure to install on a solid surface; The installation position should be easily accessible; The temperature of the installation position must be kept within the range between -20 ℃ and 40 ℃, but not too humid so as to ensure the optimum operation; Do not make the inverter exposed to the sun, which will reduce the power of the inverter due to overheating; Do not install the inverter on plaster walls to avoid making the resonant sound. i The inverter will give out tiny noise when in service(<30db). 4.1.3 Safety Clearance Comply with the minimum clearance to the wall to ensure sufficient heat dissipation space. 30cm Direction Minimum Clearance Sides 30 cm Above 30 cm Below 50 cm 30cm 30cm 50cm When several Sunmax are in parallel connection, it will produce high ambient temperature. For this situation, ensure the good operation of Sunmax by increasing its clearance from the wall and the supplying of cool air. 4.1.4 Position for Keeping When installing, keep perpendicular to the ground; Do not install horizontally; When choosing an installation position, its height should facilitate the observation of LED lights and LCD screen. 10 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 4.2 Instructions for Installation 4.2.1 Installation with Rack This bracket is applicable for Sunmax1500/1500-AU/ This bracket is applicable for Sunmax 3600/3600-AU/ 2000/2000-AU/2500/2500-AU/3000/3000-AU 40004000-AU/46004600-AU/5000/5000-AU A. Choose a wall or solid vertical surface that can support the inverter; B. Put the hanging bracket in the proper position, mark them and then drill four small holes with the depth of 40mm-45mm with an electric drill of 8mm in width. C. Put the four expansion bolts provided by KLNE to the four holes and make the hanging brackets correspond to the four holes; D. Insert the four installation bolts into the four corresponding white pads and then tighten the hanging bracket with them; E. Lightly attach the Sunmax on the bracket and then insert the two feet on the top of the inverter into the corresponding bracket holes; Installation steps for Sunmax 1500/1500-AU/2000/2000-AU/2500/2500-AU/3000/3000-AU 11 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Installation steps for Sunmax 3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU F. Then slowly pull down the inverter until the other two feet on the downside surface of the inverter access to bracket holes; G. After the above steps, mount the two safety screws provided by KLNE on the both sides on the top of the inverter with a screwdriver; H. Finally determine whether the Sunmax is firmly installed. 5 Electrical Connection WARNING! ! Electric shock due to short circuit! If cables with different voltages are laid parallel to one another, short circuits can result if the cable insulation becomes damaged. Lay all cables separately. ATTENTION! ! Electrostatic discharges can damage the Sunmax! Internal components of the Sunmax can be irreparably damaged by static discharge. Ground yourself before touching a component. 5.1 Electrical Connection System Diagram ‘A’ (Solar panel ) provides energy input for the inverter ‘B’ (DC breaker) is used for safety protection ‘C’ (Grid inverter) converts the DC power from the solar panel into AC power 12 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD ‘D’ (AC breaker) is used for safety protection ‘E’ (Electric meter) records the overall power sent out by the grid inverter ‘F’ (State grid) is the AC power provided by local power company 5.2 Connection to Grid Requirements for connection Ensure that the connection of Sunmax conforms to the connection requirements of the public grid; Ensure that the parameter setting of Sunmax conforms to the local grid requirements. Leakage detection device Sunmax is provided with complete leakage detection device, which can automatically recognize the actual leakage and normal capacitive discharge. If the leakage current exceeds the safety value of the detection device, the inverters alarm will trip and display the fault information, and automatically disconnect from the grid to prevent dangers. Insulation detection: when the input resistance of the inverter is less than 1MΩ, the inverter will stop startup and beep on error; and the red light turns on , the LCD screen shows ‘Low Isolation’. Residual Current Detection: if the abrupt change of leakage current exceeds 30mA or the continuous leakage current exceeds 300mA, the inverter will stop startup and beep on error; and the red light turns on , the LCD screen shows ‘High Ground I’. The following display is the AC terminal of Sunmax1500/1500-AU/2000/2000-AU/ 2500/2500-AU/3000/3000-AU, live wire L, neutral wire N and grounding wire G(〨) . Female insert with coupling ring Shell Pressing cap screw AC wire AC terminal of Sunmax 1500/1500-AU/2000/2000-AU/2500/2500-AU/3000/3000-AU 13 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD The live wire L, neutral wire N and grounding wire G of Sunmax1500/1500-AU/2000/2000-AU/ 2500/2500-AU/3000/3000-AU are shown below: Pin L Pin N Pin G The following displays the AC terminal of Sunmax 3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU : Shell Fale insert with Pressing screw cap AC wire coupling ring AC terminal of Sunmax3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU Use copper conductors only Use 10AWG copper wire for Sunmax 3600/4000/4600/5000 Use 12AWG copper wire for Sunmax 1500/2000/2500/3000 Product model and the corresponding current rating of the fuse at the AC terminal. Sunmax 1500,15A/Sunmax 1500-AU,15A Sunmax 2000,20A/Sunmax 2000-AU,20A Sunmax 2500,30A/Sunmax 2500-AU,30A Sunmax 3000,30A/Sunmax3000-AU,30A Sunmax 3600,30A/Sunmax 3600-AU,30A Sunmax 4000,30A/Sunmax 400-AU,30A Sunmax 4600,30A/Sunmax 4600-AU,30A Sunmax 5000,30A/Sunmax 5000-AU,30A The live wire L, neutral wire N and grounding wire G of Sunmax3600/3600-AU/4000/4000-AU/ 4600/4600-AU/5000/5000-AU are shown below: 14 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Pin L Pin N Pin G 5.3 Connection of the AC Terminal 5.3.1 Connection of Sunmax1500/2000/2000-AU The DC terminal of Sunmax1500/2000/2000-AU has one group of MC4 terminals, one positive pole and one negative pole; The following is the requirements for the installation of terminals: Same model; Same quantity; one-one correspondence; The panel array must be equipped with the plug-style connection cable, which connects with the DC terminal of Sunmax. The limit value of DC terminal is shown in the table below: Maximum input voltage Maximum total input current 450V/500V(DC) 9A/10A (DC) 5.3.2 Connection of Sunmax 2500/2500-AU/3000/3000-AU Sunmax 2500/2500-AU/3000/3000-AU has two groups of MC4 terminals, two positive poles and two negative poles; The following is the requirements for the installation of terminals: Same model; Same quantity; one-one correspondence; The panel array must be equipped with the plug-style connection cable, which connects with the DC terminal of Sunmax. 15 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD The limit value of DC terminal is shown in the table below: Maximum input voltage 500V(DC) Maximum total input current 13A (DC) 5.3.3 Connection of Sunmax 3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU The DC terminal of Sunmax 3600/3600-AU/4000/4000-AU/4600/4600-AU/5000/5000-AU has three groups of MC4 terminals, three positive poles and three negative poles; The following is the requirements for the installation of terminals: Same model; Same quantity; one-one correspondence; The panel array must be equipped with the plug-style connection cable, which connects with the DC terminal of Sunmax. The limit value of DC terminal is shown in the table below: Maximum input voltage Maximum total input current 500V/550V/550V /550V /550V (DC) 13A/18A/19A/18A/19A(DC) Use copper conductors only Use 12AWG copper wire 5.3.4 Steps for DC Terminal’s Connection ! DANGER! Danger to life due to high voltages in the Sunmax! Before connecting the PV generator, ensure that the AC line circuit breaker is switched off. 1. Check whether the wiring of two poles of PV is correct, and whether the output voltage and current of PV array are within the allowable range of Sunmax; 16 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD ! ATTENTION! Over-voltage can cause damages to Sunmax! If the DC input voltage is greater than the maximum input voltage of the inverter, the inverter will be subject to irreparable damages due to overvoltage; all the claims in the warranty period will become invalid! The open-circuit voltage of the PV array must be lower than the maximum input voltage of the inverter. ! CAUTION! Over-current will cause damages to the battery panels! Because Sunmax has current-limiting effect, if the current of PV modules exceeds the allowable maximum input current of the inverter, it will cause damage to the battery panel. 2. After confirming the above connections are correct, insert the DC terminals into their connecting ports correspondingly. The DC terminals not in use must be sealed with a sealing plug to prevent entry of water vapor. As shown in below: Sunmax 5000 Sunmax 1500 Sunmax5000-AU Sunmax1500-AU DANGER! ! Electric shock may endanger your life! Before connecting to the DC terminals, make sure that the DC Switch at the DC terminals and the circuit breakers at AC terminals are disconnected to prevent electric shock. Before inserting the DC terminals, firstly turn off the circuit breakers , operate on the Sunmax only after the DC terminals are stable. 17 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 3. After finishing all the connections, open the DC Switch, as shown in below: ATTENTION! ! The DC Switch controls the on-off at the DC terminals and it must be turned on when the Sunmax is in operation. 5.4 Starting Steps of Sunmax 1. Ensure that the voltage at the DC and AC side of Sunmax conform to the normal operating range; 2. Firstly open the DC Switch at the DC terminal, and then open the circuit breaker at the AC terminal. After self-checking of Sunmax, start normal operation. (Note: Sunmax-AU series have no separate DC Switch, so the circuit breaker at the DC terminal should be turned on.) ! ATTENTION! Danger of crushing when the terminals snap closed! When the AC terminals are snap closed, Sunmax cannot immediately get the power off and power discharge will occur inside. Before the screen is completely off, do not operate the inverter. 5.5 Stoppage of the Inverter The inverter’s DC terminals and AC terminals should be controlled with DC Swtich and circuit breakers separately. When stopping the operation of the inverter, it is necessary to disconnect circuit breaker of AC terminal firstly, and then disconnect DC Swtich of DC terminal. For any loss caused by failing to observe this requirement, KLNE will assume no warranty and no joint liabilities. 18 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD DANGER! i Danger to life due to high voltages in the Sunmax! Do not switch on the AC breaker until the PV generator has been connected and the Sunmax is securely closed. Disconnecting the power grid is allowed ! Only the circuit breaker should be used as a tool to disconnect from the power grid. 6 Setting the Country-specific Parameters Because there are varied installation regulations in different regions, the installer should make appropriate changes to the parameters of the inverter before being used. 7 Communication 7.1 Communication Ports There are two communication ports for Sunmax — RS232 and RS485 respectively. Use of RS232 RS232 serial line can be connected to a computer to monitor the operating state of the inverter, upgrade the program of inverter and modify the parameters of the inverter. To protect the normal use in the future, please tighten the RS232 port with a screw when not in use. When connecting 19 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD After connecting Use of RS 485 RS485 can connect several inverters to realize the monitoring of the inverters; There are 4 Pins in total,but only Pin 2 and 4 are in use.when not in service, please tighten the sealing cap. RS485 Port RS485 Port Note: Connecting manner of RS485 As shown in the diagram below, each 485 terminal is provided with four ports and only the port 2 and the port 4 need to be connected when being connected with a communication line. 8 System Operation Preparation before the start: 1. Check the connection Check whether Sunmax is securely tightened on the hanging bracket ; Check whether the DC terminal is correctly connected with the PV modules ; Check whether the AC terminal is correctly connected with the grid; Check whether the wiring at the AC terminal and DC terminal is secured; 20 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Check whether the circuit breakers at the AC terminals are connected securely; Check whether the Sunmax housing is fastened and sealed. 2. Confirm the parameters Check whether PV modules conform to the operating parameters of Sunmax; Check whether Sunmax conforms to the local grid regulations. Run Mode Open the DC Switch and the circuit breaker If the sunlight is enough, the green light on the inverter will be on; then the waiting period starts during which the grid parameters and PV modules are tested; after that, you will hear four ticktacks, which indicates that Sunmax has been in normal operation. Display status The inverter may have the following four states: Standby: This is a standby state; Waiting: The state means waiting for grid connection; Normal operation: this state means in normal operation; Fault state: this state means fault. LCD display is as follows: The first line of LCD State Display content Remark Waiting Initial waiting Checking xxS System checking Reconnect in xxs System checking Standby PV voltage low Normal State Pac = xxxx.x W Inverter watt at working Auto Test State Auto testing Protection auto test Fault State System xx Fault System fault Permanent State Inverter xx Damaged Inverter fault Program State Programing Update software Wait State 21 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD The second line of LCD Cycle display Display time /s Remark User: xxxx 1 The user type Spec: xxxx 1 The Inverter spec type Model:x.xkw 1 The Inverter model SW Version:xx.xx 1 The software version Etotal: xxxkwh 2 The energy total Etoday: xx.xkwh 2 The energy today Ttoday:xxhxxmin 2 The work time today PV:xxxv BUS:xxxv 2 The PV and Bus voltage AC:xxxv xx.xhz 2 The Grid voltage and frequency The fault state can be divided into system fault and inverter fault, as shown in table below: Display Operation System Fault Disconnect Grid Disconnect grid Grid V Fault Grid voltage out range Grid F Fault Grid frequency out range Low Isolation Low input isolation High PV Voltage PV input voltage high High Ground I GFCI active High Temperature Temperature too high Inverter Fault EEPROM Damaged EEPROM has problem Please Initiate System has not been initiated at the first time GFCI Damaged GFCI device damaged Sensor Damaged Output AC sensor damaged SCI Damaged The communication between the two MCU fault 22 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD Not Consistent The data is not the same for the two MCU High DC INJ Output DC Injection Too High Relay Damaged Output Relay Failure High Bus Voltage DC Bus Voltage Is Too High Auto test failed Auto test failed 2.5V Ref Fault 2.5V Reference Voltage Inside has problem 9 Opening and Closing ! ATTENTION! Static electricity may cause damages to Sunmax! The discharge of static electricity will cause irreversible damage to the parts inside of Sunmax. Please do not open the housing and touch the internal parts with hands. 9.1 Opening Sunmax Housing Note: only qualified personnel can open Sunmax! ! DANGER! The high voltage in the Sunmax will endanger your life! Before opening Sunmax housing, please ensure that: Turn off the DC Switch and the circuit breaker at AC and pull off the AC and DC terminals after confirming it is completely off. ! DANGER! Eclectic shock may endanger your life! Before the electricity is completely discharged inside of Sunmax, there are risks of high voltage and electric shock! 1. Turn off the DC Swtich after the circuit breaker at AC terminal is turned off, and then wait until the fault report on the LCD disappears; 2. Pull off the AC terminal and then pull off all DC terminals; 23 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 3. Wait for 15 min and ensure that the capacitor discharge is completed; you can loosen the six nuts on the housing and open the shell. 9.2 Closing Sunmax Housing ! DANGER! Electric shock will endanger your life! Before the housing is closed, do not open the circuit breaker; After confirming that the housing is fastened with nuts which cannot be moved, run Sunmax. 1. Tighten the cover with six nuts Tighten two nuts at opposite angles with appropriate tools, then install another two nuts at the other opposite angles, and finally install the two nuts in the middle. 2. Insert the DC and AC terminals correctly Connect DC terminals Check whether the connections of the positive terminals and the negative terminals are correct and confirm that the group string allocation is correct . Sunmax 2500/3000 only has one group of terminals and the ports are corresponding one by one; Sunmax 3600/4000/4600/5000 has three groups of terminals; check whether the positive poles and the negative poles are correctly connected; The terminals not in use should be sealed with sealing plugs, as shown in figure below: Sunmax2500/3000 Sunmax3600/4000/4600/5000 Connect the AC terminals There are clamps at the AC port; insert the AC terminal correspondingly and confirm that they are tightened. 24 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD ! Attention! Ensure that when connecting the PV panels with Sunmax, each positive and negative pole should be connected correspondingly, not reversed; otherwise, the Sunmax will not work normally. 3. Connect the circuit breaker. 10 Troubleshooting and Maintenance 10.1 Troubleshooting The common error messages and troubleshooting are as follows: No. Cause Remedy 1 <Disconnect Grid> Identify whether the grid stops power supply; Possible causes: Identify whether the AC circuit breaker is closed; Stop power supply from the grid; Identify whether the breakover of the two terminals AC circuit breaker is disconnected; The both sides of AC circuit breaker are in poor contact. 2 <Grid V fault> Possible causes: The grid voltage exceeds the scope prescribed in the local regulations. 3 <Grid F Fault> Possible cause: The grid frequency exceeds the scope prescribed in the local regulations. 4 <Low Isolation> Possible causes: The ground wires at the AC terminal are in poor contact. of AC circuit breaker is good; If there are no above problems, please contact your distributor or customer service department. When reporting error, check whether the grid voltage of the inverter is within the range prescribed in local regulations; Report this problem to the distributor or customer service department. Whether this problem is always existing or intermittently existing; Report this problem to the distributor or customer service department. Check whether the ground wire of AC is in good contact; If there is no problem, please contact the distributor or customer service department. 25 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 5 <High PV Voltage> Check whether the actual voltage at the DC side is within the specified range of the inverter; The actual voltage at the DC side exceeds the specified range of the inverter. 6 <High Ground I> If complying with the range of the inverter voltage, please contact the distributor or customer service department. Disconnect the circuit breakers at the DC side and AC side and check whether there are damages to the cables and circuit breakers at the AC side. The possible cause is that there is leakage at the AC side. 7 <High Temperature> The ambient temperature of the inverter is too high. Identify whether the ambient temperature is abnormal; Identity whether the inverter has sufficient heat dissipation space; Identify whether the cooling fin of the inverter is blocked; If the external environment is normal, please contact the distributor or customer service. 8 No Display on LCD Screen Check whether the DC terminals’ connection are stable; Check whether the DC Switch is on; Check whether the voltage at the DC end reaches the start voltage of the inverter. 10.2 Maintenance Check the heat dissipation: If the Sunmax is in low power for a long time, it is possible the inside temperature is too high, possible causes are as follows: A) There are earths in the cooling fins at the back of the housing and the heat dissipation channels are blocked; B) The installation space of Sunmax is too narrow and there is no enough space for the cooling fins to dissipate heat; C) The ambient temperature of Sunmax is too high. If necessary, clean the cooling fins on a regular basis and keep good ventilation of Sunmax; otherwise, if the temperature is too high, it will reduce its efficiency and reduce the service life of Sunmax. 26 / 27 SHANGHAI DOWELL ELECTRONIC TECHNOLOGY CO., LTD 11 Contact us If you have any questions about the operation of the inverter, please contact our DOWELL customer service. To help you, we need your assist to provide the following information: Inverter Model Sunmax serial number Displayed error message Data about the connected PV module Systems installation area Tel:+86 519 83181617 Fax: +86 519 89612658 Email: [email protected] Address: Headquarters: 4F Building 3, No.8 Lanxiang Road, Wujin Economic Development Zone, Changzhou, Jiang Su Province, China Technical service fax: +86 519 89612658 Technical service email:[email protected] 27 / 27