Download © 2009 Fast Heat, Inc. All Rights Reserved. Ground Leakage and

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Coilgun wikipedia , lookup

Control system wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Ohm's law wikipedia , lookup

Stray voltage wikipedia , lookup

Wire wrap wikipedia , lookup

Alternating current wikipedia , lookup

Thermal runaway wikipedia , lookup

Lumped element model wikipedia , lookup

Surge protector wikipedia , lookup

Galvanometer wikipedia , lookup

Rectiverter wikipedia , lookup

Metadyne wikipedia , lookup

Opto-isolator wikipedia , lookup

Residual-current device wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Earthing system wikipedia , lookup

Ground (electricity) wikipedia , lookup

Transcript
Ground Leakage and How to Reduce its Effect on Hot Runner Systems
March 2009
By Peter Kalantzis
© 2009 Fast Heat, Inc. All Rights Reserved.
All heating elements have a certain amount of electricity that “leaks” from the internal
construction of the heater to the surrounding metal sheath. This leakage is typically not a
problem where two conditions exist: a good ground connection between the mold connector and
the tool steel and a good ground connection between the mold connector and the hot runner
controller.
What is ground leakage current?
Leakage current can’t be seen, but those who have repaired hot half tools on a bench have
noticed that if the tool isn’t properly ground they can receive a nasty electrical shock. That shock
is the result of leakage current passing from the hot half plate through the person to ground.
To understand leakage current you'll need a brief understanding of typical heater construction
and what a ground is.
© 2009 Fast Heat, Inc. All Rights Reserved.
Typical heater construction:
A heating elements starts with a coil of Nichrome wire (the actual heating element) wound
around a ceramic core, which is then placed in a metal sheath and surrounded by a thermally
conductive, electrically isolating material — typically magnesium oxide (MgO).
To enhance the thermal conductivity between the coil and the metal sheath (moving heat away
from the coil to the sheath), the MgO is compacted. This compaction completely surrounds the
coil and transforms the MgO from what was once a loose powdery substance into a firm
substance with limestone consistency.
The coil’s two wires have to be connected to a controller, so a set of wiring leads are typically
welded to the coil and brought out the back of the heater. In order to provide some strain relief
and protection against moisture, the end is sealed with a high temperature epoxy.
What is ground?
The nature of electrical circuits are a bit complex for this paper, but in simple terms every
electrical circuit is based on its potential of electricity and ground gives us a reference for
measuring those circuits.
© 2009 Fast Heat, Inc. All Rights Reserved.
Suppose you are trying to measure two circuits — one an injection-molding machine and the
other a temperature controller. The circuits are from two separate AC supplies, but the grounds
are not connected. When an AC voltmeter is placed between the two grounds, you sometimes
can detect AC voltage. The reason for this is the two grounds are at different potentials and
leakage current is present.
Source of leakage current:
Now that we understand the construction of the heating element, let’s look at the actual cause.
Nearly every heating element used today in hot runner molding is constructed in such a manner
where it has, or eventually will have, some leakage of current (voltage) to ground.
Picture a simple circuit of a light bulb, switch and battery in series. When the switch is closed the
light bulb turns on. Current flows from the battery’s positive terminal through the closed switch,
through the light bulb and back to the negative terminal of the battery.
A circuit of leakage current is very similar to the light bulb circuit. Even though magnesium
oxide is an insulator, a combination of a few things allow for leakage current to occur. The
primary source is water. Moisture finds its way into a heating element because of the expansion
and contraction of the wire seal.
© 2009 Fast Heat, Inc. All Rights Reserved.
Pure water is an insulator. It is the impurities in the water between the coil and the sheath that
allows the connection to occur.
Reliability: What happens when there is NOT a good ground between the tool – mold
connector – controller?
About 99 percent of all hot runner thermocouples produced today are known as grounded
thermocouples. This means that the thermocouple has its junction or point of measurement
welded together directly to metal sheath surrounding the two wires. (See diagram below.)
Transition
(+) TC wire lead
Junction
(-) TC wire lead
When the ground between the tool-mold connector-controller is missing or becomes worn (forms
a slight resistance), the next best ground path is through the thermocouple wire. This then
exposes two major weaknesses present today in all cases.
© 2009 Fast Heat, Inc. All Rights Reserved.
First, the weakest point is in the hot runner control module. If enough current were present, the
thermocouple input circuitry would blow. This happens on most hot runner controls today with
the exception of the Pulse series which has ATP built into its input circuitry. When this failure
occurs, the module usually is damaged beyond repair. This failure causes damage in the
hundreds of dollars, not to mention the downtime.
The most cost destructive effect is when the transition in the thermocouple (this is where the
small diameter wire is connected to the lead wire) becomes a weak point. With enough leakage
current, this transition blows open. This failure is similar to a fuse blowing open. The failure here
is not so much the inexpensive thermocouple but the expensive downtime of stopping
production, opening the tool and replacing this thermocouple. This can cost thousands of dollars.
How does a ground get “lost” between the tool – mold connector – controller?
There are numerous ways, but some of the most common:
1. In most situations the ground connection between the tool and the controller is through
the mold box or junction box. The box itself serves as a grounding point when the box is
properly mounted onto the tool – tightly. If the box loosens, it can intermittently break
the ground connection between the tool and controller.
2. On each heater connector in the mold box there is a connection point for ground. If this
connector is re-wired or replaced, the ground is almost always forgotten or ignored. This
© 2009 Fast Heat, Inc. All Rights Reserved.
ground is the main point of guarantee that the ground is connected between the tool and
controller.
3. The controller itself is not grounded. On the power input the ground is loose or not
connected.
If I ensure that I have a good ground why do I need ATP?
In almost every case in an injection molding machine where consistent high amplitude vibration
is present, there is an opportunity for the mold box to loosen. This can in turn loosen the ground,
if it is left unattended.
How does ATP work?
ATP is a “non-powered” circuit specially designed for hot runner applications. There are
basically two points of protection. First, it contains a resetable PTC or “positive temperature
coefficient device” that goes into a high resistive protection mode when excessive current is
present. It basically opens the thermocouple circuit protecting the junction and controller input
circuitry. Second, a specialized protection device turns excessive “noise” and leakage current
into heat. This is primarily used for any short duration pulses present in all industrial
applications. This device serves a second function in cleaning up any noise present and giving
the controller a “cleaner” and more accurate signal to work with. Finally, it assists the PTC in its
function in protecting against leakage current.
© 2009 Fast Heat, Inc. All Rights Reserved.
When the PTC opens, when will it close again?
The PTC device's main purpose is to remain in an open state showing up as an open
thermocouple on the diagnostics in the hot runner controller. Once that ground fault is removed
(by tightening down the mold box or reconnecting the ground wire), the PTC will automatically
reset itself. This saves the thermocouple from blowing open and a control module from
becoming unusable.
So what is ATP?
ATP can be thought of as a “guard dog” against leakage current. It is always there and ready to
assist in the protection of the thermocouple transition and control module.
Do I have to connect any power to the ATP once I connect the Smart Mold Box™ to my tool?
No, the ATP circuit does not require any power. It is powered by the thermocouple connection.
Does the ATP affect the thermocouple reading?
No, it continues to output the standard acceptable range of temperatures. There is more loss seen
through connections in the thermocouple cable and mold connector than through the ATP circuit.
© 2009 Fast Heat, Inc. All Rights Reserved.