* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download LAB WM-454 - Teledyne LeCroy
Mains electricity wikipedia , lookup
Mathematics of radio engineering wikipedia , lookup
Oscilloscope history wikipedia , lookup
Rectiverter wikipedia , lookup
Tektronix analog oscilloscopes wikipedia , lookup
Chirp compression wikipedia , lookup
Opto-isolator wikipedia , lookup
Spectral density wikipedia , lookup
Converting Spectrum Analyzer Option Readouts from dBm to dBV LAB WM-454 February 27, 2012 Summary The LeCroy Spectrum Analyzer option reads spectral values in dBm (decibels relative to 1 mW). In some applications, users would like to read spectral values in dBV (decibels relative to 1 V). This application brief outlines a simple rescaling to accomplish this. The LeCroy Spectrum Analyzer option, shown in Figure 1, displays the frequency spectrum of an acquired signal using an interface like that of an RF spectrum analyzer. This includes readouts in dBm based on the voltage into the scope 50 Ω input. In some applications (e.g. when using a probe that has a high impedance input) users would like to read spectral amplitudes in dBV (decibels relative to 1 V). A simple rescaling allows this to be accomplished and by using the Save Table feature the spectrum peak table can be converted using an Excel spreadsheet. Figure 1: The LeCroy spectrum analyzer option uses an RF spectrum analyzer format to display the frequency spectrum of an acquired waveform including amplitude readouts in decibels relative to 1 mW (dBm) LeCroy Corporation Converting Spectrum Analyzer Option Readouts from dBm to dBV page | 1 of 3 The spectrum analyzer reads in dBm assuming a 50 Ohm load. You can recalibrate this to read in dBVrms using the following derivation: 2 2 dBm= 10*Log 10 ((V /R)/ .001) = 10*log10 (V ) +10*Log10 (1000/R) for R=50: dBm = 20*Log10(V) + 10*Log10(20) But 20*Log10(V) =dBV, so dBm= dBV+13 or dBV= dBm-13 So simply subtracting 13 dB from the table values for each harmonic will give you the correct values in dBVrms. Let’s do a measurement to check. In Figure 2 we have analyzed a 400 Hz sine wave. The sine has a measure rms voltage level of 1.0367 V as seen in the parameter P1 readout. Figure 2: Analysis of a 400 Hz sine The Spectrum Analyzer peak table shows a component a 400 Hz with an amplitude of 13.3 dBm. Applying our conversion the level 0.3dBVrms. Doing the math to convert back to volts we expect the rms voltage level of the 400 Hz component to be 1.035 V. This is within 0.1%. LeCroy Corporation Converting Spectrum Analyzer Option Readouts from dBm to dBV page | 2 of 3 LeCroy scopes have the ability to export the spectrum analyzer peak table in comma delimited (.csv) file format. This can be imported into a spreadsheet with the rescaling done there. Figure 3 shows the SaveTable tab on the Save/Recall dialog box. Figure 3: The Save Table setup to save the Spectrum Analyzer peak table in comma delimited (.csv) format Once you have saved the table you can import it into a spreadsheet and apply the rescale operation. Figure 4 shows the peak table and spectrum display for a 400 Hz square wave with an Excel spreadsheet overlaid showing the rescale operation added to the table. Figure 4: The exported spectrum analyzer peak table imported into a spreadsheet with the rescale operation added to convert the table of peak values into dBVrms Using the Save Waveform selection under the file pull down menu you can save the whole spectrum trace and rescale that as well. For very small voltages it might be more convenient to convert the voltages to dBm V (decibel referenced to 1 mV). Simply add 60 dB from the dBV value to get the value in dBm V. Adding another 60 dB will give the value in dBμV. LeCroy Corporation Converting Spectrum Analyzer Option Readouts from dBm to dBV page | 3 of 3