Download Installation Instructions

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Current source wikipedia , lookup

Tube sound wikipedia , lookup

Transformer wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Islanding wikipedia , lookup

Three-phase electric power wikipedia , lookup

Electrical substation wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power engineering wikipedia , lookup

Electric battery wikipedia , lookup

Stray voltage wikipedia , lookup

Audio power wikipedia , lookup

Solar micro-inverter wikipedia , lookup

History of electric power transmission wikipedia , lookup

Surge protector wikipedia , lookup

Integrating ADC wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Power inverter wikipedia , lookup

Rechargeable battery wikipedia , lookup

Transformer types wikipedia , lookup

Alternating current wikipedia , lookup

Schmitt trigger wikipedia , lookup

Voltage regulator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Rectifier wikipedia , lookup

AC adapter wikipedia , lookup

Power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
DPS3
Power Supply/Charger
Overview:
DPS3 power supply/charger converts low voltage AC input into 6VDC, 12VDC or 24VDC @ 2.5A of continuous supply
current (see specifications). This general purpose power supply has a wide range of applications for access control, security
and CCTV system accessories that require additional power.
Specifications:
Visual Indicators:
Input:
• 6VDC or 12VDC output - use TP1640;
24VDC output - use T2428100.
• AC input and DC output LED indicators.
Output:
• Extremely compact design.
• Includes battery leads.
• Snap Track compatible
(order Altronix model number ST3).
Features:
• 6VDC, 12VDC or 24VDC selectable output.
• 2.5A continuous supply current.
• Filtered and electronically regulated output.
• Short circuit and thermal overload protection.
Board Dimensions (L x W x H approx.):
Battery Backup:
3.5” x 3” x 2” (88.9mm x 76.2mm x 50.8mm).
• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switch over to stand-by battery when AC fails.
• Maximum charge current 0.35A.
•
Battery short circuit protection (circuit breaker).
Voltage Output/Transformer Selection Table:
Switch Position
Transformer Requirements
(Recommended Altronix Part #’s)
1
2
6VDC
ON
OFF
16VAC / 40VA (TP1640)
12VDC
OFF
OFF
16VAC / 40VA (TP1640, T24130 or T2885)
24VDC
OFF
ON
28VAC / 100VA (T2885)
Note: Transformers with higher VA ratings may be used for all output voltages above as long as you
do not exceed 28VAC or 45VDC.
Output Voltage
Installation Instructions:
The DPS3 should be installed in accordance with The National Electrical Code and all applicable Local Regulations.
1. Mount the DPS3 in desired location.
2. Set DC output voltage with switches (refer to Voltage Output/Transformer Selection Table).
3. Connect proper transformer to terminals marked [AC] (Voltage Output/Transformer Selection Table).
Use 18 AWG or larger for all power connections (Battery, DC output).
Keep power-limited wiring separate from non power-limited wiring (115VAC / 60Hz Input, Battery Wires). Minimum 0.25” spacing must be provided.
4. Measure output voltage before connecting devices. This helps avoiding potential damage.
5. Connect devices to be powered to terminals marked [+ DC ---].
6. When the use of stand-by batteries is desired, they must be lead acid or gel type.
Connect battery to the terminals marked [+ BAT ---] (battery leads included).
Use two (2) 12VDC batteries connected in series for 24VDC operation.
Note: When batteries are not used, a loss of AC will result in the loss of output voltage.
LED Diagnostics:
Red (DC)
ON
ON
OFF
OFF
Green (AC)
ON
OFF
ON
OFF
Power Supply Status
Normal operating condition.
Loss of AC. Stand-by battery supplying power.
No DC output. Short circuit or thermal overload condition.
No DC output. Loss of AC. Discharged or no battery present.
Terminal Identification:
BKLYN, NY 11220
ST3 Drawing:
0.875”
22.2mm
12, 24 VDC
SMP3 6,POWER
SUPPLY
SW1
SW2
6V
ON
OFF
12 V
OFF
OFF
24 V
OFF
ON
0.625”
15.9mm
ON
ALTRONIX CORP.
DPS3 - Board Drawing:
0.125”
3.2mm
0.3125” (7.9mm)
SW1
SW2
3.4375”
87.3mm
3.25”
82.55mm
2.75”
2.6875”
68.26mm 69.85mm
AC
DC
+ DC --
+ BAT --
AC
AC
Terminal Legend Function/Description
Low voltage AC input (Voltage Output/Transformer Selection Table).
For 6VDC output use 16VAC or higher with 24VA power rating or higher.
AC /AC
For 12VDC output use 16VAC or higher with 40VA power rating or higher.
For 24VDC output use 28VAC with 85VA power rating or higher.
Caution: Do not apply voltages above 28VAC (28VAC is maximum input rating)
- DC +
6VDC-12VDC-24VDC @ 2.5A continuous power-limited output.
+ BAT Stand-by battery connections. Maximum charge rate 300mA.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: [email protected]. Lifetime Warranty, Made in U.S.A.