* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download SMP3PM (Page 1)
Power over Ethernet wikipedia , lookup
Electrification wikipedia , lookup
Electric power system wikipedia , lookup
Electrical substation wikipedia , lookup
Three-phase electric power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Stray voltage wikipedia , lookup
Electric battery wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power engineering wikipedia , lookup
Audio power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power inverter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Transformer types wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Schmitt trigger wikipedia , lookup
Voltage regulator wikipedia , lookup
Rechargeable battery wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Power supply wikipedia , lookup
Mains electricity wikipedia , lookup
Altronix ® SMP3PM Supervised Power Supply/Charger Overview: The SMP3PM is a supervised power limited supply/chargers that will convert a low voltage AC input, into a 12VDC or 24VDC power limited output, with 2.5 amps of continuous supply current (see specifications). Specifications: AC Switch selectable 12VDC or 24VDC power limited output Maximum charge current .5 amps 2.5 amps continuous supply current at 12/24VDC Filtered and electronically regulated outputs Built-in charger for sealed lead acid or gel type batteries Automatic switch over to stand-by battery when AC fails (zero voltage drop) • AC input and DC output LED indicators • AC fail supervision (form "C" contacts) • Low battery supervision (form "C" contact) • Short circuit and thermal overload protection • Includes battery leads Board Dimensions: 6.5”L x 3.5”W x 1.75H AC • • • • • • AC FAIL SW1 ALTRONIX CORP. NO BROOKLYN, NY 11220 MADE IN U.S.A. C VR1 NC C NO SW1 NC SMP3PM BAT FAIL FOR 12V SW1 AND SW2 OPEN AC SUPERVISED POWER SUPPLY / CHARGER PTC DC PTC1 FOR 24V SW1 AND SW2 CLOSED + BAT --- + DC --- Specified at 25˚ C ambient. Voltage Output/Transformer Selection Table: Output VDC 12VDC Switch Position SW 1, 2 Open Max. Load DC 2.5 amps Transformer Requirements (Recommended Altronix Part #’s) 16 VAC / 40 VA ( TP1640, T24130 or T2885) 24VDC SW1, 2 Closed 2.5 amps 28 VAC / 85 VA (T2885) Note: Transformers with higher VA ratings may be used for all output voltages above as long as you do not exceed 28VAC or 45VDC. Installation Instructions: The SMP3PM should be installed in accordance with The National Electrical Code and all applicable Local Regulations. 1. Mount the SMP3PM in desired location. 2. Set the SMP3PM-CTX to desired DC output voltage via SW1 (see power supply voltage output specifications chart). 3. Connect proper transformer to terminals marked AC (see voltage output/transformer selection table). Use 18 AWG or larger for all power connections (Battery, DC output). Use 22 AWG to 18 AWG for power limited circuits (AC Fail/Low Battery reporting). 4. Connect devices to be powered to terminals marked + DC -. Note: It is good operating practice to measure and verify output voltage before connecting devices to ensure proper operation of equipment. 5. When the use of stand-by batteries are desired, they must be lead acid or gel type. Connect battery to terminals - BAT + as marked on the unit (battery leads included). Use two (2) 12VDC batteries connected in series for 24VDC operation. Note: When batteries are not used a loss of AC will result in the loss of output voltage. 6. Connect appropriate signaling notification devices to AC Fail & Low battery supervisory relay outputs marked NC, C, NO. IISMP3PM-Rev. 091498 LED Diagnostics: Red (DC) Green (AC) Power Supply Status ON ON OFF OFF ON OFF ON OFF Normal operating condition Loss of AC, Stand-by battery supplying power No DC output Loss of AC. Discharged or no stand-by battery. No DC output. Terminal Identification: Terminal Identification Function/Description AC/ AC Low voltage AC input (see voltage output/transformer selection table). For 12VDC output use 16VAC or higher with 24 VA power rating or higher. For 24VDC output use 28VAC with 85 VA power rating or higher. Caution: Do not apply voltages above 28 VAC (28 VAC is maximum input rating) + DC - 12 / 24VDC 2.5 amps continuous power limited output. AC FAIL NC, C, NO Used to notify loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized when AC power is present. Contact rating 1amp @ 120VAC / 28VDC Low Battery NC, C, NO Used to indicate low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present. Contact rating 1amp @ 120VAC / 28VDC. Low battery threshold: 12VDC output threshold set @ approximately 10.5VDC, 24VDC output threshold set @ approximately 21VDC. - BAT + Stand-by battery connections. Maximum charge rate .5 amps. AC AC Maximum input voltage not to exceed 28VAC AC FAIL SW1 ALTRONIX CORP. NO BROOKLYN, NY 11220 MADE IN U.S.A. C VR1 NC C NO SW1 NC SMP3PM BAT FAIL FOR 12V SW1 AND SW2 OPEN AC SUPERVISED POWER SUPPLY / CHARGER PTC DC PTC1 FOR 24V SW1 AND SW2 CLOSED + BAT --- + DC --- Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice. MEMBER Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 website: www.altronix.com, e-mail: [email protected], Lifetime Warranty, Made in U.S.A.