Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
An introduction to EN 60204-1 Stewart Robinson TÜV SÜD Product Service TÜV SÜD Product Service BS EN 60204-1:2006+A1:2009 Safety of Machinery - Electrical Equipment of Machines Part 1: General Requirements. Defined Scope This part of IEC 60204 applies to the application of electrical and electronic equipment and systems to machines not portable by hand while working, including a group of machines working together in a coordinated manner, but excluding higher level systems aspects (e.g. communications between systems). The standard defines the basic terminology and specifies general design methods to help designers and manufacturers in achieving safety in the design of machinery. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 2 EN 60204-1 Scope • EN 60204-1 gives safety guidance and recommendations on electrical equipment for “non-portable” machinery. • EN 60204-1 refers to machinery that operates with nominal supply voltages below 1,000V for alternating current or 1,500V for direct current • EN 60204-1 covers control circuits and control functions, wiring practices and protection against electrical shock TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 3 27/06/2013 1 EN 60204-1 Out of scope • BS EN 60204-1 does not include guidance on:• machinery designed for outdoor use in mines and in flammable atmospheres • machinery that produces explosive material • machinery that operates as a sewing machine. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 4 EN Standards and European Directives EN 60204-1 is harmonised against the Machinery Directive and the Low Voltage Directive “A” type apply to all machines. “B” type are designed to promote safety and split in to B1 and B2. “C” type apply to a specific type of machine. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 5 EN 60204-1 and BS 7671 (IET Wiring Regulations) • BS 7671 - Requirements for electrical installations. IET Wiring Regulations. Seventeenth edition. – The guidelines cover all aspects of designing and installing electrical wiring and temporary or permanent power systems in buildings • As a general rule BS 7671 applies up to the connection of the electrical supply to the machine isolator. EN 60204-1 applies from that point onwards TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 6 27/06/2013 2 EN 60204-1 Contents • There are 18 clauses in the normative part of the standard 1. 2. 3. 4. 5. 6. 7. 8. 9. Scope Normative references Definitions General requirements Incoming supply conductor terminations and devices for disconnecting and switching off Protection against electric shock Protection of equipment Equipotential bonding Control circuits and control functions TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 7 EN 60204-1 Contents 10.Operator interface and machine-mounted control devices 11.Controlgear: location, mounting, and enclosures 12.Conductors and cables 13.Wiring practices 14.Electric motors and associated equipment 15.Accessories and lighting 16.Marking, warning signs and reference designations 17.Technical documentation 18.Verification TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 8 Definitions - Examples Barrier • A part providing protection against direct contact from any usual direction of access. Control Circuit (of a machine) • A circuit used for the control, including monitoring, of a machine and the electrical equipment. Control Device • A device connected into the control circuit and used for controlling the operation of the machine (for example position sensor, manual control switch, relay, contactor, magnetically operated valve). TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 9 27/06/2013 3 Definitions - Examples Control gear • Switching devices and their combination with associated control, measuring, protective, and regulating equipment, also assemblies of such devices and equipment with associated interconnections, accessories, enclosures, and supporting structures, intended in principle for the control of electrical energy consuming equipment. Direct opening action (of a contact element) • achievement of contact separation as the direct result of a specified movement of the switch actuator through non-resilient members (for example not dependent upon springs) [IEC 60947-5-1, K.2.2] TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 10 Definitions - Examples Emergency stop device • Manually actuated control device used to initiate an emergency stop function Emergency switching off device • Manually actuated control device used to switch off the supply of electrical energy to all or a part of an installation where a risk of electric shock or another risk of electrical origin is involved TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 11 Definitions - Examples Failure • Termination of the ability of an item to perform a required function. Fault • State of an item characterized by inability to perform a required function, excluding the inability during preventive maintenance or other planned actions, or due to lack of external resources. “Failure” is an event, as distinguished from “fault”, which is a state In practice the terms fault and failure are often used synonymously TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 12 27/06/2013 4 Definitions - Examples Live Part • Conductor or conductive part intended to be energized in normal use, including a neutral conductor. Protective Bonding • Equipotential bonding for protection against electric shock. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 13 Electrical Hazards EN 60204-1: Chapter (6) and (7) TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 14 Risk and Consequence General Requirements: • Risk due to electrical equipment is part of the risk assessment of machine : Equipment failure leading to electrical shock. Control circuit failure leading to malfunction of the machine. Disturbance / interruption of the power source leading to malfunction of the machine. EMC problems leading to malfunction of the machine. Release of stored energy leading to unexpected movements / electrical shock. High surface temperatures leading to burns. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 15 27/06/2013 5 Equipment selection • Correct selection of electrical components and devices based upon the: Intended use. Conformity to applicable standards. Applied according to manufacturers instructions. Suitability for purpose. Ability to withstand the expected influence. Appropriate for the intended use. Suitably placed / positioned. Readily identifiable with physical durable marking of the component or device. • Low voltage switchgear / control gear assemblies must comply with IEC 60439. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 16 EMC Requirements • Emission Protection. Power supply filtering Cable shielding. Enclosures designed to minimize RF radiation. RF suppression techniques – filters. • Immunity Protection The design of functional earth bonding system. Connect sensitive electrical circuits to chassis. Connect the chassis to earth (PE) (low RF impedance, short distance). Functional earthing conductor (FE) minimize common disturbance. The separation of sensitive circuits from disturbance sources. Enclosures should be designed to minimize RF transmission. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 17 Electrical Supply and Isolation A single incoming supply is recommended for machines. However where a second supply for electronic equipment with different voltage is required (for example from a 24vdc PSU), this should be derived from main machine supply. • Isolators must be readily accessible located between 0.6 m and 1.9 m above servicing level (with an upper limit 1.7 m recommended). • Isolators should be lockable (LOTO type) and attached to the machine i.e. on-board. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 18 27/06/2013 6 Electrical Supply and Isolation • They should disconnect all supplies!!! • If not intended for emergency operation it is recommended that the isolators should be coloured black or grey. • Emergency off isolators must be coloured red and yellow. • It must have one off (isolated) and one on position marked with "O" and "I“. • The isolator must be clearly identified as to its function i.e. what it isolates. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 19 Electrical Supply and Isolation • The isolator should ideally be interlocked to the panel door. If this is not possible then IP2X protection must be installed to all devices that remain live when to door is opened. • The isolator must not be mounted on the door itself. • For large complex machinery there may be a need for more than one incoming supply, therefore consideration must be given to ensuring all supplies can be appropriately isolated by the use of protective interlocks for correct operation to prevent hazardous situations arising, including damage to the machine. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 20 Electrical Supply and Isolation TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 21 27/06/2013 7 Supply Termination Incoming Supply Terminations and the Neutral Conductor: • All terminals for incoming supply connection must be clearly identified e.g., L1, L2, L3, N, PE, and 400V (or the appropriate voltage). • Should be clearly indicated in technical documentation installation diagram and circuit diagram. • The Neutral should have a separate insulated terminal, labelled ‘N’. • There should be no connection between neutral and protective bonding circuit inside electrical equipment . TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 22 Protection against electric shock Persons must be protected from electric shock from: Direct contact. Indirect contact. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 23 Protection against indirect contact The risk in this case is an insulation fault between live parts and exposed conductive parts. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 24 27/06/2013 8 Protection by enclosures Protection against electric shock by locating live parts inside enclosures TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 25 Protection by enclosures • The opening of the enclosure (i.e. opening doors, lids, covers, and the like) must be by one of the following: – The use of a key or tool – Disconnection of live parts inside before opening which can be achieved by Interlocking the door with a disconnecting device. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 26 Enclosures Enclosure doors should not be wider than 0.9m Ideally vertical hinges, with an angle of opening of at least 95° There must be no opening between enclosures containing electrical equipment and compartments containing coolant, lubricating or hydraulic fluids, or those into which oil, other liquids, or dust can penetrate. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 27 27/06/2013 9 Defeat Interlocked Isolator • However it is allowed to defeat the interlock with a special device or tool provided that: • It is always possible to operate and lock the disconnecting device in the off position. When closing the door, the interlock is automatically restored. • All live parts, used for resetting or adjusting while connected must have at least IP2X protection. • All other live parts inside the enclosure must have at least IP1X protection. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 28 Protection by Insulation • Live parts protected by insulation shall be completely covered with insulation that can only be removed by destruction. • Such insulation shall be capable of withstanding the mechanical, chemical, electrical, and thermal stresses to which it can be subjected under normal operating conditions. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 29 Potential sources of electrical shock from wiring TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 30 27/06/2013 10 Protection Against Residual Voltages • Live parts with a residual voltage of greater than 60v must discharge to 60v or less within 5 s (as long as the discharge does not interfere with the proper functioning of the equipment) • If this is not possible then a durable warning notice with required delay before opening time on it should be fitted. • In the case of plugs or similar devices the minimum discharge time shall be less than 1 second, otherwise protection to IP2X must be installed or fitted. • If neither can be achieved such as on removable collectors on conductor wires, conductor bars, or slip-ring assemblies then additional switching devices or appropriate warning devices (warning notice), must be installed or fitted. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 31 Appliance Classes Appliance Class Marking Protection Class 0 No Marking Single level of insulation no protective-earth Chassis Connected to Electrical Earth (PE) Class I Class II "Class II" „Double Insulated„ Double Insulated Supplied from a SELV Class III (Separated Extra-Low Voltage) Power Source. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 32 Protection against indirect contact - touch voltage Use class II equipment or equipment with the equivalent level of insulation. This is provided by one or more of: – Class II electrical devices or apparatus with double insulation, reinforced insulation or by equivalent insulation in accordance with IEC 61140. – Switchgear and control gear assemblies with total insulation in accordance with IEC 60439-1. – Supplementary or reinforced insulation in accordance with article 412 of IEC 60364-4-41. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 33 27/06/2013 11 Protection by the use of Extra Low Voltage • Protective Extra Low Voltage PELV: Limited voltage. 25vac or 60vdc for dry conditions 6vac or 15vdc in all other cases One side connected to protective earth Safe separation (by double or reinforced insulation) of the PELV system to all non PELV systems. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 34 Protection of equipment Equipment should be protect against the effects of: • Over current arising from a short circuit. • Overload and / or loss of cooling of motors. • Abnormal temperature. • Loss of or reduction in the supply voltage. • Over speed of machines / machine elements. • Earth fault / residual current. • Incorrect phase sequence. • Over voltage due to lightning and switching surges. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 35 Control Functions - Examples • Start Functions. • Stop Functions. • Operating Modes. • Suspension of Safety Functions and / or Protective Measures. • Normal Operation. • Other Control Functions such as Hold to Run Devices, Two Hand Controls, and Enabling devices. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 36 27/06/2013 12 Start Functions Shall only be possible only when all safety functions and / or protective measures are in place and fully operational. Where safety functions and / or protective measures cannot be applied for certain operations, manual control of such operations by hold-to-run controls, together with enabling devices must be activated and fully controlled. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 37 Stop Functions Stop functions fall into three categories Stop category 0 - Stopping by immediate removal of the power. Stop category 1 - A controlled stop with power available to the actuators to achieve the stop, then final removal of power. Stop category 2 - A controlled stop with power left available to the actuators. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 38 Stop Functions • Emergency Stop where the emergency stop device complies with EN ISO 13850 An emergency stop can only be a category 0 or 1 stop. The initiation of the emergency stop must supersede all modes of operation and other functions. There must be no automatic restart of the machine on reset. • The switching of an ‘Emergency Off’ device (EMO) but only if the hazard is from electricity. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 39 27/06/2013 13 Recommended colours – Push buttons Operator Interface and Machine-Mounted Control Devices – Colour-coding for Push Buttons: Colour Meaning Explanation Emergency YELLOW Abnormal Actuate under abnormal condition BLUE Mandatory Actuate when requiring mandatory action GREEN Normal Actuate to initiate normal conditions WHITE GREY No specific meaning assigned Examples of application Additional description Actuate in hazardous Emergency Stop / Off. situation or Initiation of emergency function. emergency RED Intervention to suppress abnormal condition . Intervention to restart an interrupted automatic cycle. Reset function. Start / On (preferred) Stop / Off For general initiation of functions except Start / On emergency stop Stop / Off Stop / On Stop / Off (preferred) BLACK TÜV SÜD Product Service 27/06/2013 RED is permitted also for only Stop / Off function, but it is recommended that RED is not used near an emergency operation device. RED shall not be used for Start / On. Reset push-buttons shall be BLUE, WHITE, GREY or BLACK. Where they also act as a Stop / Off button, the colours WHITE, GREY or BLACK are preferred with the main preference being for BLACK. WHITE, GREY or BLACK are the preferred colours for push-button actuators that alternately act as Start / On and Stop / Off push-buttons. Where WHITE for Start / On and for Stop / Off is used a additional description shall be used for the identification of this push-button actuator. BS EN 60204-1:2006+A1:2009 Slide 40 Examples of poor wiring TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 41 Marking, Warning Signs and Reference Designations: Where appropriate the system / machine must be marked with all mandatory signage and appropriate warning labels and signs, and identifiers for cables etc., as previously discussed. Some examples being: Electrical Shock TÜV SÜD Product Service 27/06/2013 Hot Surface BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 42 27/06/2013 14 Verification and Testing If there is no dedicated product standard (a ‘C’ standard) for the machine the verifications shall always include the items a), b) and f) and may include one or more of c) to e), in the following order: • a) Verification that electrical equipment complies with its technical documentation. • b) in case of protection against indirect contact by automatic disconnection, conditions for protection by automatic disconnection shall be verified • c) Insulation resistance test. • d) Voltage test. • e) Protection against residual voltage. • f) Functional tests. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 43 Verification and Testing – Functional Tests f) Functional tests: The functions of electrical equipment shall be tested, particularly those relating to safety and safeguarding, verification shall be completed for all steps neccessary for safe intendend use. Verification is more than just verification of electrical parameters, it must also include the verification of all mechanical safety devices such as interlocks, ventilation, and cooling etc......... It must also include verification of the operating manual and manufacturers instructions as necessary. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 44 Verification and Testing – Documentation of Results Results of the inspections and verifications should reflect the following: The date of the test or inspection. The actual results. Whether or not the system or machines passed or failed the test or inspection. Any comments. Any corrective action required or carried out. The name and signature of tester. It should also be remembered that where a portion of the machine and its associated equipment is changed or modified, that portion shall be verified and retested, as is appropriate. TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 45 27/06/2013 15 BS EN 60204-1:2006+A1:2009 TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 46 BS EN 60204-1:2006+A1:2009 Thank you for Your Time and for Listening Any Questions TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 Slide 47 Thank you for listening For more information contact: +44 (0)1642 345637 [email protected] www.tuv-sud.co.uk/machinery TÜV SÜD Product Service 27/06/2013 BS EN 60204-1:2006+A1:2009 TÜV SÜD Corporate Presentation Slide 48 27/06/2013 16