TÜV NORD CERT GmbH
Hanover Office
Am TÜV 1
30519 Hannover
Germany
Page 1 of 1
Attachment to IECEx TUN 06.0011 X Issue 2
IECEx TR:
DE/TUN/ExTR06.0037/02
IECEx QAR:
DE/QAR/PTB/06.0012/03
File reference:
13 217 112912
In future, the analogue data transmitter type IM31-**Ex-* is manufactured according to the
documents listed in the test report.
The required tests were performed according to the current standards.
The following changes were performed:
-
Some new components/component changes (non safety relevant)
Changes of the pc board
The electrical data and all other details remain unchanged.
“Special conditions for safe use” (only for zone 2 applications)
• The Analogue Data Transmitter type IM31-**Ex-* has to be installed in a suitable housing
according to IEC 60079-15 in such a way, that a degree of protection of at least IP 54 according
to IEC 60529 is reached.
• Using the switches on the front side as well as the connecting and disconnecting of energised
non intrinsically safe circuits is only permitted if no explosion hazardous atmosphere exists.
• For the supply circuit arrangements have to be taken externally, that the rated voltage is
exceeded not more than 40% by transient disturbances.