Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Operating and installation instructions MSE Haustechnik ZL Keep for future use! Valid from 30 October 2010 General information WARNING It is important to comply with the following points in the interest of personal safety. Children may not play with the operating elements of the control unit or the remote control. Store the remote controls out of the range of children. ■ Make sure that no persons or objects are in the range of movement of the driven parts (blinds, window, etc.). Disconnect the MSE from the supply voltage if cleaning or other maintenance work must be performed. Fig. 1 MSE Haustechnik ZL The MSE Haustechnik ZL (MSE) is an electronic control unit for the direct control of 230 V AC sun shading system drives. This motor control unit is equipped with a time logic function that allows for convenient operation of your sun shading system. Because of its compact design, the MSE can be accommodated in a flush-mounted junction box. The motor and the MSE are supplied via the power line. The sun shading control system can be operated via local push buttons and via a higher level central control unit. Several motor control units can be combined into a group and controlled jointly from a push button. Intended use The device was developed to control sun shading systems. The approval of the manufacturer must be obtained for uses outside of the purposes listed in these instructions. Safety instructions WARNING The electrical installation must be performed by a certified electrician in accordance with the electrical installation regulations published by the Association of German Electrical Engineers (VDE 0100) or the standards and regulations of the country in which the device is being installed. The electrician must observe the installation instructions included with the electrical device. WARNING If hazard-free operation cannot be assumed, the device may not be started or must be deactivated. This assumption is justified if The housing or the supply lines show signs of damage, The device is no longer working. 890591_0•en•20.09.2011 Information on the electrical installation An on-site overload current protection device (fuse) and a disconnecting and isolating switch to switch off the entire system must be provided. The device meets the EMC guidelines for use in residential and commercial areas. Installation The MSE Haustechnik ZL (Fig. 3) is intended for flush mounting in a commercially available deep flush-mounted switch box; installation in a deep flush-mounted junction box with a diameter of 70 mm/56 mm is recommended. Only such lines as are used for the wiring of the motor control unit should be routed into this box. Alternatively, the MSE can be supplied in a surface-mounted housing (not for outdoor use, Fig. 4). Installation must be indoors. The device is not suitable for use in damp interiors. The electrical connection of the motor control unit is performed using spring terminals (Fig. 2) according to the wiring diagram on the reverse (see Fig. 5). Handling the spring terminals Fig. 2 Connecting and disconnecting the line connections After the wire is stripped, it is pressed into the terminal (1) until the insulation on the wire enters the terminal and the line is securely held in the terminal (2). To disconnect the line, the appropriate unlock button needs to be pressed in as far as it will go using a screw driver, and the line then removed from the terminal (3). We reserve the right to carry out improvements 1 Initial operation After the device is fully mounted and the power supply is connected, the device is ready for operation. Function of the MSE Haustechnik ZL Local operation After the local operating element is actuated, the sun shading product moves in the corresponding direction and stops after 2 seconds. If the "UP/DOWN" button continues to be pushed, the MSE switches to lock mode. The button may then be released. The sun shading product moves to the UP or DOWN limit position. If the movement should stop in lock mode, the button for the opposite direction of movement must be pressed briefly. Central operation Local operation is disabled for the duration of the central command; if lock mode is active, it is cleared. NOTE: If the drive does not reach the "UP" or "DOWN" limit switch within 3 minutes, the drive is cut off automatically, regardless of whether a local or a central move command was applied. Technical data MSE Haustechnik ZL Min. Typ. Operating voltage 207 230 Power consumption Switching capacity at 230 V∼/cos ϕ = 0.6 Central voltage active Central current active 207 230 700 VA 253 V AC 1 1.5 2 mA -0.5 0 4 V AC Local voltage active 207 230 253 V AC Local current active 1 1.5 2 mA -0.5 0 4 V AC Local voltage inactive Enclosure Dimensions Installation in flush-mounted box, see Fig. 3 Surface-mounted housing, see Fig. 4 Maintenance All connections After use, the device must be disposed of according to legal regulations or brought to your local recycling centre. VA Central voltage inactive Protection class (without PE) Disposal V AC Input control NOTE:Multiple outside lines (phases) may be used in a system if they are fed through a common earth leakage circuit breaker. Failure to comply with the product information in these instructions and use of the device in a manner that contravenes its intended use and purpose may result in the manufacturer refusing to honour warranty claims for product damage. In this case, liability for secondary harm to persons or damage to property will also be excluded. Follow also the instructions in the operating manual of your sun shading system. The automatic or manual operation of the sun shading system when iced over as well as using the sun shading system during severe weather may cause damage and must be prevented by the user by taking suitable precautions. 253 1 Degree of protection/safety class Liability Unit Drive output Grouping via the control line Several MSE can be combined to a group via the shared control line and operated centrally via an operating element. Refer to Fig. 5 (wiring diagram). There are no parts within the device that require maintenance. Max. Supply 230 V~, 50 Hz In flush-mounted box In surface-mounted housing IP 20 IP 54 II Connection Spring terminals Terminals Power line, drive line 0.5...1.5 mm2 Control line, Push button line 0.5...1.5 mm2 Test standards Product standard: EMC basic standards: DIN EN 60730: 1996-1 DIN EN 50081: Part 1 1993-3 DIN EN 50082: Part 2 1997-11 Miscellaneous Automatic operation Type 1 Software class A Location of use Clean ambient conditions Conformity Viewable at www.warema.de Ambient conditions Operating temperature Storage temperature Rel. humidity (non-condensing) 0 20 40 °C 0 20 50 °C 10 40 85 %RH Article numbers MSE Haustechnik ZL UP MSE Haustechnik ZL AP 1002 415 1002 422 WAREMA Renkhoff SE Hans-Wilhelm-Renkhoff-Strasse 2 97828 Marktheidenfeld, Germany 2 We reserve the right to carry out improvements 890591_0•en•20.09.2011 88 53 Fig. 3 26.0 mm 20.4 mm 88 48.0 mm 48.0 mm SE Haustechnik ZL for installation in a flush-mounted M box 890591_0•en•20.09.2011 Fig. 4 Surface-mounted housing of the MSE Haustechnik ZL We reserve the right to carry out improvements 3 Fig. 5 MSE Haustechnik ZL wiring diagram 4 We reserve the right to carry out improvements 890591_0•en•20.09.2011 F Supply line 230 V AC 50 Hz / 6 A (3*) UP DOWN Central UP 230 V AC Central DOWN 230 V AC L1 For further information, see documentation to wiring diagrams "Anschlusspläne", Art. No.: 816 345 E P/C PE N L1 X1 L N N (2*) (1*) P L N N P MSE Haustechnik ZL L Netz 230V X3 Motor 230V N X2 - Max. group size of 200 motor control units, see voltage drop diagram. - Central control line length, see voltage drop diagram. - The power line length is limited by the total motor current. The maximum number of drives per circuit depends on their current consumption and the upstream fuse. - Max. switching capacity of the MSE: see "Technical data".. - Only pushbuttons may be used. (1*) When grouping, 7 x 1.5 mm² must be routed between the MSE! (2*) Terminal "P" may only be used to connect a push button and should not be looped through. Attention! The line length to a group push button or single push button is max. 25 metres. (3*) Multiple outside lines (phases) may be used within a single system if they are passed through a shared earth leakage circuit breaker. A max. of 5 drives with a rated motor current of 1 A may be connected to a B6A inline circuit breaker. Attention! All circuits must be switched off for maintenance work. Central Central Group Group Lokal 230V X3 X1 Zentral 230V Lokal 230V Motor 230V N X2 Netz 230V X4 P MSE Haustechnik ZL L X1 L N N N PE P P MSE Haustechnik ZL L L2 X3 Motor 230V N X2 Netz 230V Single pushbutton (Motor 3) (2*) Lokal 230V X4 Zentral 230V Terminal BL BK BN GNYE BL BK BN GNYE 1 2 3 1 2 3 Plug-and-socket connection 2 3 M 1~ 1 Motor 2 1 2 3 1 2 3 2 3 M 1~ 1 Only one drive may be connected per MSE! Motor 1 Attention! X4 Zentral 230V Group pushbutton (Motor 1 + 2) H05RR-F 4 G 0,75 BK, Type WAREMA NYM-J 3 x 1,5 NYM-J 5 x 1,5 NYM-J 7 x 1,5 Connection: Floating contacts of the sun shading control system/ GA Compact Legend: Supply line (2.Phase) 230V AC 50 Hz / 6 A (3*) PE N L2 Central UP Central DOWN BL BK BN GNYE 1 2 3 1 2 3 2 3 M 1~ 1 Motor 3 Supply line 230 V AC to next MSEs