Download 54315 Trailer Remote Receptacle.fm

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Valve RF amplifier wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Ohm's law wikipedia , lookup

Josephson voltage standard wikipedia , lookup

Standby power wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Audio power wikipedia , lookup

Opto-isolator wikipedia , lookup

CMOS wikipedia , lookup

Schmitt trigger wikipedia , lookup

Decibel wikipedia , lookup

NEMA connector wikipedia , lookup

Voltage regulator wikipedia , lookup

Power MOSFET wikipedia , lookup

Power electronics wikipedia , lookup

Surge protector wikipedia , lookup

Rectiverter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
REMOTE POWER RECEPTACLE INSTALLATION GUIDELINES
For SB Trailer Units with SmartPower™ Option
DANGER: An improperly installed remote power receptacle could lead to serious injury
or death! Only a qualified electrician should perform this installation.
DANGER: The remote power cable must be physically separated from the trailer’s fuel
lines. Fuel lines in the presents of an electrical short can result in a fire!
WARNING: Take precautions to ensure the unit will not accidentally start while you are
servicing the system.
CAUTION: The remote power receptacle and electrical wiring must be installed in such
a manner as to not interfere with the normal operation of the trailer.
NOTE: The power receptacle factory installed onto the unit is the preferred mounting
method. Alternative mounting methods are the responsibility of the installer.
• The installer is responsible for mounting the remote receptacle securely and safely onto the
trailer.
• The installer is responsible that all electrical wiring is safely installed and all connections and
grounds are made per the supplied instructions and wiring diagram.
• To prevent damage to the refrigeration units electric motor, the combined power cable length
from the unit to the power supply, must not exceed the recommendations shown in Figure 1.
• The installer is responsible for installing all supplied safety labels and meeting applicable
electrical codes.
Thermo King Unit
B
Warehouse
Power
Supply
Voltage
A
75 ft. (22.8 m) Max.***
A
B
Standby Power Cord
to Remote Receptacle
Wire
Gauge****
Cable
Type
Power Supply
Circuit Breaker
Power Plug
Rating
Plug
Configuration
Plug
Type
230/3/60 (14 hp motor)
8 AWG
W
70 amps
50A
*CS8364
TwistLock
460/3/60 (14 hp motor)
10 AWG
S00W
40 amps
30A
**NEMA L16-30
TwistLock
460/3/60 (24 hp motor)
8 AWG
W
60 amps
50A
*CS8164
TwistLock
Figure 1: Standby Power Cable and Circuit Breaker Size Recommendations
*CS = California Standard
**NEMA = National Electrical Manufacturers Association
*** 75 ft. (22.8 m) Maximum total power conductor length
**** Minimum Recommendation
TK 54315-2-IM (Rev. 2, 01/12) Copyright© 2009 Thermo King Corp. Minneapolis, MN, USA
ADDITIONAL UNIT GROUND WIRE - FIGURE 2
IMPORTANT: An additional ground wire is required from the Thermo King unit to the chassis of
the trailer. This additional ground wire can be found attached to the rear of the high voltage
box.
1. After the Thermo King unit has been installed, choose a location on the trailer’s chassis to attach
the additional unit ground wire.
•
Remove any paint and debris from this area and drill the appropriate size hole.
•
Route the ground wire to the trailer’s chassis and attach it securely with appropriate (installer
supplied) hardware.
POWER CABLE to HIGH VOLTAGE BOX - FIGURE 2
2. Open the curbside door and remove the access cover from the high voltage box.
•
From under the unit locate the flexible conduit at the rear of the high voltage box.
•
Route the power cable (installer supplied) through this conduit and into the high voltage box.
IMPORTANT: A water tight connection at the end of the conduit is required.
Additional Ground Wire
(Thermo King Supplied)
Flexible Conduit
(Thermo King Supplied)
A water tight connection at the end
of the conduit is required.
Power Cable (installer supplied)
Figure 2: Rear View of the High Voltage Box
2
POWER CABLE CONNECTIONS INSIDE BOX - FIGURE 3
3. Route enough power cable into the high voltage box to make the electrical connections.
•
Strip 12 inches (304.8 mm) of insulation to expose the four individual wires. Secure the power
cable to the bottom of the high voltage box to the cable tie mount as shown.
•
Route the three power wires to the On/Off switch, strip the wire ends and install sleeve crimps
(installer supplied) firmly onto each wire.
•
Attach the wires to the On/Off switch per the supplied electrical schematic. See Figure 5.
IMPORTANT: Make sure the high voltage power wires do not rub against the low voltage
ground stud inside the box!
•
Neatly route and secure the power wires to the side of the box with the cable tie as shown.
•
Route the ground wire from the power cable up to the high voltage ground stud, strip the wire
end and install a terminal ring (installer supplied) firmly onto the wire.
•
Attach the high voltage ground wire securely onto the high voltage ground stud.
On/Off
Switch
Low Voltage
Ground Stud
(see note)
High Voltage
Ground Stud
(behind wires)
Cable Tie
Mounts
High Voltage
Power Wires
High Voltage Ground Wire
Figure 3: Power Cord Connections Inside Box
3
REMOTE POWER RECEPTACLE SCHEMATIC - FIGURE 4
4. Attach the power cord wires from the On/Off switch to the remote power receptacle as shown in
the following schematic.
FACTORY WIRED TO
MOTOR CONTACTOR
HIGH VOLTAGE GROUND STUD
(Located Inside High Voltage Box)
L1A
L2A
L3A
1L1
3L2
5L3
ON / OFF SWITCH
(Located Inside High Voltage Box)
GRN / YEL
2T1
4T2
6T3
BRN
GRY
BLK
Installer Supplied Wiring
X
Y
GRY
BRN
GRN / YEL
BLK
Z
GND
REMOTE POWER RECEPTACLE
Figure 4: Electrical Schematic
4
NAMEPLATES and SAFETY COVER - FIGURE 5
5. The installer is responsible for installing the following supplied components:
•
The system voltage and a high voltage warning nameplate must be installed near the remote
receptacle.
•
The yellow plastic switch cover must be installed onto the On/Off switch inside the high voltage
box.
COMPLETING THE INSTALLATION
1. Turn the On/Off power switch inside the high voltage box to the ON position.
2. Reinstall the access cover onto the high voltage box.
3. Close and secure the curbside door.
4. Plug the correct voltage power cord into the remote power receptacle.
5. Turn the unit controls ON and operate the unit in electric standby mode.
6. Verify the unit operates in both diesel and electric standby modes.
230/3/60
460/3/60
System Voltage Nameplate
(one nameplate of actual system voltage is supplied)
High Voltage Nameplate
Switch Cover
Figure 5: On/Off Switch Cover Shown Installed
5
Figure 6: Remote Power Receptacle Dimensions
6