* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Model KCS/KCP Ratings MPACt 1500 Controller
Ground (electricity) wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Voltage regulator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Crossbar switch wikipedia , lookup
Electrical substation wikipedia , lookup
Current source wikipedia , lookup
Power MOSFET wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Surge protector wikipedia , lookup
Light switch wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Model KCS/KCP Automatic Transfer Switches MPACt 1500 Controller Standard Features D D D D D D D D D D D Ratings Voltage: 208--600 VAC 50/60 Hz Current: Standard-Transition: 30--4000 amps * Programmed-Transition: 150--4000 amps * Transfer Switch Standard Features D UL 1008 listed at 480 VAC file # E58962 (automatic), # E86894 (nonautomatic) D CSA certification available D IBC seismic certification available D Standard-transition or programmed-transition modes of operation with either automatic or non-automatic control D Available in 2, 3, or 4 pole configurations D Electrically operated, mechanically held mechanism D Double-throw, mechanically interlocked design (break-before-make power contacts) D Solid, switched, or overlapping neutral (make-before-break) D High withstand and close-on ratings D Design suitable for emergency and standby applications on all classes of load, 100% tungsten rated through 400 amps D Standard-transition transfer time less than 100 milliseconds (6 cycles @ 60 Hz) D Silver alloy main contacts D Gold-flashed engine start contacts rated 2 amps @ 30 VDC/250 VAC D Front-accessible contacts for easy inspection D Front-replaceable main and arcing contacts (800--4000 amps) D Reliable, field-proven solenoid mechanism D Switching mechanisms lubricated for life D Internal manual operating handle D Main shaft auxiliary position-indicating contacts (rated 10 amps @ 32 VDC/250 VAC) D NEMA type 1, 12, 3R, 4, and 4X enclosures available * Contact the factory for 4000 amp models. D D D D D D D D Microprocessor-based controller Environmentally sealed user interface LCD display, 4 lines x 20 characters, backlit Dynamic function keypad with tactile feedback pushbuttons allows complete programming and viewing capability at the door LED indicators: Source available, transfer switch position, service required (fault), and “not in auto” Broadrange voltage sensing (208--600 VAC) on all phases Phase-to-phase sensing and monitoring with 0.5% accuracy on both sources Frequency sensing with 0.5% accuracy on both sources Anti-single phasing protection Phase rotation sensing for three-phase systems Real-time clock with automatic adjust for daylight saving time and leap year Time-stamped event log Fail-safe transfer for loaded test and exercise functions DIP switches: password disable and maintenance Modbusr RTU and Modbusr TCP/IP protocols (Modbusr register map available) RJ45 connector for 10/100 ethernet connection USB port with read/write compatibility Isolated RS-485 ports One-year limited warranty Programmable Features D Programming and monitoring methods: d Monitoring and password-protected programming at the door using the keypad and display d Program and monitor using a PC with Monitor III integrated generator set and ATS monitoring software d Transfer files through the USB port D System voltage and frequency D Voltage unbalance D Over/undervoltage and over/underfrequency for all phases of the normal and emergency sources D Adjustable time delays D Load/no load/auto-load test and load/no-load exercise functions D Programmable inputs and outputs D Time-based and current-based[ load control D Load bank control for exercise or test D Pre/post-transfer, nine individual time delays for selected loads D ABC/BAC/none phase rotation selection with error detection D Resettable historical data D In-phase monitor D Password protection, three security levels [ Requires current sensing kit. G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 1 MPACt 1500 Controller Features User Interface LED Indicators D D D D Communications Contactor position: source N and source E Source available: source N and source E Service required (fault indication) Not in automatic mode LCD Display D D D D D D D D D D D D D D D D D D System status Line-to-line voltage Line-to-neutral voltage Active time delays Source frequency Preferred source selection System settings Common alarms Load current, each phase[ Inputs and outputs Faults Time/date Address Event history Maintenance records Exerciser schedule Exerciser mode Time remaining on active exercise USB Data Logger D Time-stamped voltage and frequency readings D Minimum and maximum current and voltage readings for a selected time period Programmable Features Dynamic Function Tactile Keypad Operations D D D D D D USB port with read/write capability Isolated RS-485 ports RJ-45 connector for 10/100 ethernet connection Modbusr RTU and Modbusr TCP/IP protocols (Modbusr register map available) D USB Port. Upload or download files from a PC or a memory device through the USB port. d Application software d Event history files d Language files d Parameter settings d Usage reports d Feature configuration D D D D Scroll up/down/forward/back Increase/decrease/save settings End time delay Start/end test or exercise Reset fault Lamp test D D D D D D D D D D D DIP Switches D Maintenance mode D Password disable Event History D View up to 99 time and date-stamped events on the display or on a personal computer equipped with optional Monitor III software. D Download up to 2000 events with Monitor III software or download complete event history file to a PC or a memory device connected to the USB port. Main Logic Board Inputs and Outputs D Two (2) programmable inputs D Two (2) programmable outputs, isolated form C (SPDT) contacts rated 1 amp @ 30 VDC, 500 mA @120 VAC Main Board I/O Specifications Output contact type Isolated form C (SPDT) Output contact rating 1 amp @ 30 VDC, 500 mA @120 VAC I/O terminals wire size range #12--24 AWG D D D D D D D D D D D D D System voltage, 208--600 VAC * System frequency, 50/60 Hz * Single/three-phase operation * Standard/programmed-transition operation * Preferred source selection Phase rotation: ABC/BAC/none selection with error detection Voltage and frequency pickup and dropout settings Voltage unbalance, enable/disable In-phase monitor: enable/disable and phase angle Transfer commit/no commit Source/source mode: utility/gen, gen/gen, utility/utility, or utility/gen/gen for 3-source systems Passwords, system and test Time, date, automatic daylight saving time enable/disable Time delays (see table) Exerciser: calendar mode, loaded/unloaded up to 21 events Test: loaded/unloaded/auto load (1--60 minutes) Remote test: loaded/unloaded Automatic override on generator failure (loaded test and exercise) Peak shave delay enable/disable Current monitoring[ Pre/post-transfer, 9 individual time delays for selected loads Current-based load control settings: high/low current levels and load add/remove priority for 9 separate loads [ Prime power sequence alternates between two generator sets Resettable historical data * System parameters factory-set per order [ Requires optional current sensing kit. Modbusr is a registered trademark of Schneider Electric. G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 2 MPACt 1500 Controller Features, continued Programmable Inputs External time delay input External battery fault External common fault Inhibit transfer Load shed to force transfer to OFF (programmed- transition models only; requires accessory) D Peak shave/area protection input D External test D Three-source system disable D D D D D Programmable Outputs D D D D D D D D D D D D D D D D D D D D D D D D D D D Chicago alarm control Common alarm events Contactor position Exercise active Failure to acquire standby source Failure to transfer Generator engine start, source N and E I/O module faults Load bank control Load control active (pre/post transfer delay, up to 9 outputs) Loss of phase fault, source N and E External battery fault Non-emergency transfer Not in automatic mode Over/underfrequency faults, source N and E (generator) Over/undervoltage faults, source N and E Peak shave/area protection active Phase rotation error, source N and E Preferred source supplying load Software-controlled relay outputs (four maximum) Source available, preferred and standby Standby source supplying load Synchronizing output Test active Transfer switch auxiliary contact fault Transfer switch auxiliary contact open Voltage unbalance Voltage and Frequency Sensing Default Adjustment Range Undervoltage dropout 90% of pickup 75%--98% Undervoltage pickup 90% of nominal 85%--100% 115% of nominal* 106%--135% Parameter Overvoltage dropout * Overvoltage pickup 95% of dropout 95%--100% Unbalance enable Disable Enable/Disable Unbalance dropout 20% 5%--20% Unbalance pickup 10% 3%--18% 0.5 sec. 0.1--9.9 sec. Underfrequency dropout 99% of pickup 95%--99% Underfrequency pickup 90% of nominal 80%--95% Overfrequency dropout 101% of pickup 101%--115% Overfrequency pickup 110% of nominal 105%--120% 3 sec. 0.1--15 sec. Voltage dropout time Frequency dropout time * 690 volts, maximum. Default = 110% for 600 volt applications. Adjustable Time Delays Time Delay Default Engine start, Source S2 3 sec. Engine start, Source S1 (gen/gen) 3 sec. Engine cooldown, Source S2 5 sec. Engine cooldown, S1 (gen/gen) 2 sec. Fail to acquire standby source 1 min. Fail to acquire preferred source 1 min. Transfer, preferred to standby 3 sec. Transfer, standby to preferred 15 min. Adjustment Range 0--6 sec. [ 0--60 min. Transfer, off to standby 1 sec. Transfer, off to preferred 1 sec. Fail to synchronize 60 sec. 10 sec -- 15 min. Auto load test duration 30 min. 1--60 min. (1 min. increments) Prime power run duration 6 min. 6 min. -- 100 days (6 min. increments) 1 sec. -- 60 min. Load Control Time Delays: Pretransfer to preferred 0 sec. Post-transfer to preferred 0 sec. Pretransfer to standby 0 sec. Post-transfer to standby 0 sec. Load add Source1/Source2 0 sec. Load remove Source1/Source2 0 sec. Note: 0--60 min. Time delays are adjustable in 1 second increments, except as noted. [ Engine start time delay can be extended to 60 minutes with an External Battery Supply Module Kit. G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 3 Application Data Note: Data is subject to change. Refer to the transfer switch dimension drawings and wiring diagrams for planning and installation. Auxiliary Position Indicating Contacts (rated 10 amps @ 32 VDC/250 VAC) Number of Contacts Indicating Normal, Emergency Environmental Specifications Operating Temperature StandardTransition ProgrammedTransition 30--230 2, 2 N/A 260--600 8, 8 — 150--600 — 8, 8 800-1200 8, 8 8, 8 1600--4000 8, 8 7, 7 --20C to 70C (--4F to 158F) Switch Rating, Amps Storage Temperature --40C to 85C (--40F to 185F) Humidity 5% to 95% noncondensing Input and Output Connection Specifications Component Wire Size Range Main board I/O terminals #12--24 AWG I/O module terminals #14--24 AWG UL-Listed Solderless Screw-Type Terminals for External Power Connections Range of Wire Sizes Copper or Aluminum ] Switch Rating, Amps 30--150 KCS 200 KCS 230 A (208--480 V) KCS Normal, Emergency, and Load (per phase) Neutral (3-pole) Ground (3) #14 to 4/0 (3) #6 to 3/0 (3) #4 AWG to 600 KCMIL or (6) 1/0-- to 250 KCMIL (1) #14 AWG to 4/0 AWG (1) #14 AWG to 4/0 AWG w (1) #14 AWG to 4/0 AWG 230 A (600 V) KCS (1) #4 AWG to 600 KCMIL or (2) 1/0-- to 250 KCMIL (3) #4 AWG to 600 KCMIL or (6) 1/0-- to 250 KCMIL 150--400 KCP 260--400 KCS (1) #4 AWG to 600 KCMIL or (2) 1/0-- to 250 KCMIL (3) #4 AWG to 600 KCMIL or (6) 1/0-- to 250 KCMIL 600 (2) #2 AWG to 600 KCMIL (6) #2 AWG to 600 KCMIL 800--1000 (4) 1/0 AWG to 750 KCMIL (12) #2 AWG to 600 KCMIL 1200 (4) 1/0 AWG to 750 KCMIL (16) 1/0 to 750 KCMIL 1600--2000 (6) 1/0 AWG to 750 KCMIL (24) 1/0 to 750 KCMIL 2600--3000 (12) 1/0 AWG to 750 KCMIL (36) 1/0 to 750 KCMIL (12) 1/0 AWG to 750 MCM (12) 1/0 AWG to 750 MCM 4000 (3) #4 AWG to 600 KCMIL or (6) 1/0-- to 250 KCMIL (3) #4 to 500 KCMIL (18) 1/0 AWG to 750 MCM ] Use 75_C minimum Cu/Al wire for power connections. w Copper only Codes and Standards The ATS meets or exceeds the requirements of the following specifications: D CSA C22.2 No. 178 certification at 600 VAC available, file # LR58301 D EN61000-4-4 Fast Transient Immunity Severity Level 4 D EN61000-4-5 Surge Immunity Class 4 (voltage sensing and programmable inputs only) D IEC Specifications for EMI/EMC Immunity: d CISPR 11, Radiated Emissions d IEC 1000-4-2, Electrostatic Discharge d IEC 1000-4-3, Radiated Electromagnetic Fields d IEC 1000-4-4, Electrical Fast Transients (Bursts) d IEC 1000-4-5, Surge Voltage d IEC 1000-4-6, Conducted RF Disturbances d IEC 1000-4-8, Magnetic Fields d IEC 1000-4-11, Voltage Dips and Interruptions D IEC 60947-6-1, Low Voltage Switchgear and Control Gear; Multifunction Equipment; Automatic Transfer Switching Equipment D IEEE Standard 446, IEEE Recommended Practice for Emergency and Standby Power Systems for Commercial and Industrial Applications D IEEE 472 (ANSI C37.90A) Ring Wave Test D NEMA Standard ICS 10--2005, Electromechanical AC Transfer Switch Equipment D NFPA 70, National Electrical Code D NFPA 99, Essential Electrical Systems for Health Care Facilities D NFPA 110, Emergency and Standby Power Systems D Seismic certification in accordance with the International Building Code is available. (Accessory kit is required for seismic certification.) d IBC 2000, referencing ASCE 7-98 and ICC AC-156 d IBC 2003, referencing ASCE 7-02 and ICC AC-156 d IBC 2006, referencing ASCE 7-05 and ICC AC-156 D Underwriters Laboratories UL 508, Standard for Industrial Control Equipment D Underwriters Laboratories UL 1008, Standard for Automatic Transfer Switches for Use in Emergency Standby Systems file # E58962 (automatic), # E86894 (nonautomatic) G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 4 Weights and Dimensions Note: Weights and dimensions are provided for reference only. Refer to the transfer switch dimension drawings for planning and installation. See your local distributor for dimension drawings. Weights and dimensions are shown for transfer switches in NEMA type 1 enclosures, type 3R enclosures, and open units. Consult the factory for NEMA type 12, 4, and 4X enclosures. Model 30--200 1, 3R 2,3,4 791 (31) 450 (18) 314 (12.4)] 28 230 (208--480V) 1, 3R 2,3,4 1223 (48) 560 (22) 362 (14.3)] 52 (115) 56 (123) 59 (131) 230 (600 V) 260--600 1, 3R 2,3,4 1702 (67) 610 (24) 514 (20.2)] 179 (395) 183 (403) 188 (414) 800--1000 1, 3R 1600--2000 1600--2000F[ 2600--3000 4000 ** Depth 2-Pole (62) 3-Pole 30 (65) 4-Pole 31 (68) 2,3,4 1932 (76)* 864 (34) 515 (20.3)] 220 (485) 231 (510) 238 (525) 1 3,4 2286 (90) 963 (38) 688 (27.1) — 356 (785) 379 (835) 3R 3,4 2286 (90) 940 (37) 717 (28.2) — 356 (785) 379 (835) 1 3,4 2286 (90) 963 (38) 1220 (48) — 472 (1040) 494 (1090) 3R 3,4 2286 (90) 940 (37) 1434 (56.4) — 472 (1040) 494 (1090) 1 3,4 2286 (90) 963 (38) 688 (27.1) — 472 (1040) 494 (1090) 3R 3,4 2286 (90) 940 (37) 869 (34.2) — 356 (785) 379 (835) 1 3,4 2286 (90) 963 (38) 1524 (60) — 649 (1430) 679 (1495) 3R 3,4 2286 (90) 940 (37) 1738 (68.4) — 649 (1430) 679 (1495) 1 3,4 2311 (91) 1524 (60) 1836 (72.3) — 975 (2149) 1056 (2328) 3R 3,4 2529 (99.6) 2310 — 1436 (3165) 1523 (3357) 1606 (63.2) (91) 1, 3R 2,3,4 1702 (67) 610 (24) 514 (20.2)] 179 (395) 183 (403) 188 (414) 1, 3R 2,3,4 1932 (76)* 864 (34) 515 (20.3)] 220 (485) 231 (510) 238 (525) 1600--2000F[ 2600--3000 4000 ** * [ ] w ** Width 800--1000 1600--2000 KCS Standard Transition Height 150--600 1200 KCP Programmed Transition Weight kg (lb.) Poles 1200 KCS Standard Transition Dimensions mm (in.) NEMA Type Amps 1 3,4 2286 (90) 963 (38) 688 (27) — 463 (1020) 485 (1070) 3R 3,4 2286 (90) 940 (37) 717 (28.2) — 463 (1020) 485 (1070) 1 3,4 2286 (90) 963 (38) 1220 (48) — 533 (1175) 556 (1225) 3R 3,4 2286 (90) 940 (37) 1434 (56.4) — 533 (1175) 556 (1225) 1 3,4 2286 (90) 963 (38) 688 (27) — 533 (1175) 556 (1225) 3R 3,4 2286 (90) 940 (37) 869 (34.2) — 533 (1175) 556 (1225) 765 (1685) 1 3,4 2286 (90) 963 (38) 1524 (60) — 735 (1620) 3R 3,4 2286 (90) 940 (37) 1738 (68.4) — 735 (1620) 765 (1685) 1 3,4 2311 (91) 1524 (60) 1836 (72.3) — 975 (2149) 1056 (2328) 3R 3,4 2528 (99.5) 1436 (3165) 1523 (3357) 1606 (63.2) 2310 (91) — 30--200 2,3,4 787 (31) 445 (17.5) 296 (11.6) 8 (17) 9 (20) 11 (23) 230 (208--480V) 2,3,4 1219 (48) 457 (18.0) 330 (13.0) 17 (37) 21 (45) 24 (53) 230 (600V) 260--600 2,3,4 1422 (56) 610 (24) 362 (14.3) 31 (68) 34 (74) 36 (80) 2,3,4 1829 (72) 864 (34) 508 (20) 68 (150) 78 (170) 90 (196) 2,3,4 2210 (87) 965 (38) 584 (23) 68 (150) 78 (170) 90 (196) 1600--2000 3,4 2286 (90) 965 (38) 1219 (48) 1600--2000F 3,4 2210 (87) 965 (38) 635 (25) — 190 (420) 213 (470) 2600--3000 3,4 2286 (90) 965 (38) 1524 (60) — 213 (470) 243 (535) 800--1000 1200 Open Unit w Includes mounting feet F = Front connected On 30--1000 amp models, the NEMA type 3R enclosures have a security cover on the controller that extends 54 mm (2.1 in.) beyond the door. Dimensions shown for open units are the minimum required enclosure size. Open units weights are shipping weights for the contactor only. Contact the factory for 4000 amp models. G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 5 Weights and Dimensions, continued Model KCP Programmed Transition NEMA Type Amps Dimensions mm (in.) Poles Height Weight kg (lb.) Width Depth 2-Pole 1422 (56) 610 (24) 362 (14.3) 38 800--1000 2,3,4 1829 (72) 864 (34) 508 (20) 80 (175) 94 (205) 108 (235) 1200 2,3,4 2210 (87) 965 (38) 584 (23) 80 (175) 94 (205) 108 (235) 3,4 2286 (90) 965 (38) 1219 (48) 1600--2000F 3,4 2210 (87) 965 (38) 635 (25) — 252 (555) 274 (605) 2600--3000 3,4 2286 (90) 965 (38) 1524 (60) — 300 (660) 329 (725) Open Unit w 41 (90) 4-Pole 2,3,4 1600--2000 (84) 3-Pole 150--600 44 (96) [ F = Front connected w Dimensions shown for open units are the minimum required enclosure size. Open units weights are shipping weights for the contactor only. Withstand and Close-On Ratings (WCR) Standard- and Programmed-Transition Models Maximum current in RMS symmetrical amperes when coordinated with customer-supplied fuses or circuit breakers. All values are available symmetrical RMS amperes and tested in accordance with the withstand and close-on requirements of UL 1008. Application requirements may permit higher withstand ratings for certain size switches. Contact Kohler Co. for assistance. Note: For specific breaker ratings, refer to the tables on pages 7 through 9. Withstand Current Ratings in RMS Symmetrical Amperes Current-Limiting Fuses “Any” Breaker Rating [[ Short Time Duration, Cycles Fuse Class Amps, Max. Max. Voltage, VAC Short Time Withstand Ratings ** 60 J 10,000 600 N/A — 480 200 J 10,000 600 N/A — 200,000 480 200 J 10,000 480 N/A — 230 KCS (480 V) 100,000 480 300 J 10,000 480 N/A — 230 KCS (600 V) 200,000 600 600 J 800 L 35,000 600 N/A — 600 J 35,000 600 N/A — 42,000 [ 480 N/A — 800 L 65,000 240 N/A — Switch Rating, Amps Fuse Rating, Amps Max. Voltage, VAC Max. Amps 30 KCS 100,000 480 104 KCS 150 KCS 200,000 200 KCS 70 KCS 150 KCP 225 KCP 260 400 600 200,000 600 800 1000 1200 200,000 600 1600 L 50,000 600 36,000 18 1600 ] 2000 ] 200,000 600 3000 L 100,000] 600 65,000w 30 2600 3000 200,000 600 4000 L 100,000 600 65,000w 30 4000 * 200,000 600 5000 L 100,000 600 65,000w 18 [[“Any” breaker ratings are based on 1.5 cycles for 30--230 amps and 3 cycles for 260--4000 amps. Applicable to breakers with instantaneous trip elements. [ Applicable to 2-pole, 3-pole, and conventional 4-pole switches only. Overlapping neutral switches have “any” breaker ratings of 35,000 amps. ] Optional front-connected service limited to 85,000 amps for specific and any breaker ratings. * Contact the factory for 4000 amp models. ** Short time ratings are provided for applications involving breakers that do not have instantaneous trips for systems coordination. w Withstand rating only (non UL test) G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 6 Ratings with Specific Manufacturers’ Circuit Breakers The following charts list power switching device withstand and close-on ratings (WCR) in RMS symmetrical amperes for specific manufacturers’ circuit breakers. Circuit breakers are supplied by the customer. Switch Rating, amps Molded-Case Circuit Breakers WCR, amps RMS Voltage, Max. Manufacturer Square D GE 70 * 22,000 480 ITE Cutler-Hammer ABB Merlin Gerin Square D GE ITE 104 * 22,000 480 Cutler-Hammer ABB Merlin Gerin 42,000 240 Square D GE ITE 150 * 200 * 230 * 22,000 480 Square D Cutler-Hammer ABB Merlin Gerin Cutler-Hammer 50,000 480 GE Siemens 150 [ Square D 42,000 600 Cutler-Hammer GE Type FH FC, FI KA, KC, KH, KI, LA, LH TB1 TEL, THED, THLC1, THLC2 TFL CED6, ED6, HED4, HED6 CFD6 FD6, FXD6, HLD6 FCL, Tri-Pac FB FD, FDC, HFD HJD, JD, JDB, JDC HKD, KD, KDB, KDC, LCL, Tri-Pac LA S1 S3 CE104, CE106 FC, FI KA, KC, KH, KI, LA, LH TB1 TEL, THED, THLC1, THLC2 TFL CED6, ED6, HED4, HED6 CFD6 FD6, XD6, HLD6 FCL, Tri-Pac FB FD, FDC, HFD HJD, JD, JDB, JDC HKD, KD, KDB, KDC, LCL, Tri-Pac LA S1 S3 CE104, CE106 CF250 JG TEL, THED, THLC1 TFL, THFK, THLC2 SFL, SFP, TFJ, TFK SGL4, SGP4, TLB4 CFD6, FD6, FXD6, HFD6 CJD6, HHJD6, HHJXD6, HJD6, JD6, JXD6, SCJD6, SHJD6, SJD6 KA, KC, KH, KI LC, LI LA, LH FD, FDC, HFD HJD, JD, JDB, JDC LCL, Tri-Pac LA, HKD, KD, KDB, KDC S3 CF250 CJ400 HJD, JDC, JGH, JGC HKD, CHKD, KDC HLD,CHLD, LDC, CLDC SFL, SFP TJL4V, TJL1S--6S, TBC6 SGL1, SGL4, SGP1, SGP4 HFD, HFXD HJD, HJXD, SHJD KC CK400N, CK400NN, CM1250HH JGC KDC LDC, CLDC SGL1, SGL4, SGP1, SGP4 * Standard-transition models KCS only [ Programmed-transition models KCP only G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 7 Max. Size, amps 80 100 250 100 150 225 125 150 250 100 150 250 400 125 150 100 100 250 100 150 225 125 150 250 100 150 250 400 125 150 100 250 250 150 225 250 400 250 400 250 300 400 150 250 400 150 250 400 250 400 600 250 600 600 250 400 250 400 250 400 600 600 Ratings with Specific Manufacturers’ Circuit Breakers, continued Switch Rating, amps Molded-Case Circuit Breakers WCR, amps RMS Voltage, Max. Manufacturer Cutler-Hammer GE 225 [ 260 50,000 480 Siemens Square D Cutler-Hammer 225 [ 230 * 42,000 600 GE 260 Siemens Cutler-Hammer GE 50,000 480 Siemens 400 Square D Cutler-Hammer 42,000 600 GE Siemens Type HJD, JDC, JGH, JGC HKD, CHKD, KDC HLD,CHLD, LDC, CLDC MDL, CMDL, HMDL, CHMDL, NGS, NGH, NGC SFL, SFP TBC4 TBC6, TJL4V, TJL1S--6S SGL1, SGL4, SGL6, SGP1, SGP4, SGP6 TBC8, TKL4V, TKH8S--12S, TKL8S--12S SKL8, SKP8; SKH8 HFD, HFXD HJD, HJXD, SHJD HLD, HLXD, SHLD LMD, LMXD, HLMD, HLMXD, HMG MD, MXD, HMD, HMXD, SMD, SHMD KC CK400N, CK400NN, CM1250HH LC CK800N, CK800NN, CM1600HH HJD; JGC KDC LDC, CLDC TBC4 TBC6, SGL1, SGL4, SGL6, SGP1, SGP4, SGP6 TBC8, TKL4V, TKL8S--12S, SKL8, SKP8 HLMD, HLMXD, HMD, HMXD, SHMD HKD, CHKD, KDC HLD, CHLD, LDC, CLDC MDL, CMDL, HMDL, CHMDL, NGS, NGH, NGC TBC4 TBC6, TJL4V, TJL1S--6S SGL1, SGL4, SGL6, SGP1, SGP4, SGP6 TBC8, TKL4V, TKH8S--12S, TKL8S--12S SKH8, SKL8, SKP8 HJD, HJXD, SHJD HLD, HLXD, SHLD LMD, LMXD, HLMD, HLMXD, HMG MD, MXD, HMD, HMXD, SMD, SHMD CK400N, CK400NN, CM1250HH LC CK800N, CK800NN, CM1600HH KDC LDC, CLDC TBC4 TBC6, SGL1, SGL4, SGL6, SGP1, SGP4, SGP6 TBC8, TKL4V, TKL8S--12S, SKL8, SKP8 HLMD, HLMXD, HMD, HMXD, SHMD * Standard-transition models KCS only [ Programmed-transition models KCP only G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 8 Max. Size, amps 250 400 600 800 250 400 600 600 800 800 250 400 600 800 800 250 400 600 800 250 400 600 400 600 800 800 400 600 800 400 600 600 800 800 400 600 800 800 400 600 800 400 600 400 600 800 800 Ratings with Specific Manufacturers’ Circuit Breakers, continued Switch Rating, amps Molded-Case Circuit Breakers WCR, amps RMS Voltage, Max. Manufacturer Cutler-Hammer GE 50,000 480 Siemens 600 Square D Cutler-Hammer 42,000 600 GE Siemens GE ITE 480 65,000 800 1000 1200 Square D 600 Cutler-Hammer ABB 42,000 480 Merlin Gerin Type HLD, CHLD, LDC, CLDC MDL, CMDL, HMDL, CHMDL, NGS, NGH, NGC TBC6, TJL4V, TJL1S--6S SGL1, SGL4, SGL6, SGP1, SGP4, SGP6 TBC8, TKL4V, TKH8S--12S, TKL8S-12S SKH8, SKL8, SKP8 HLD, HLXD, SHLD LMD, LMXD, HLMD, HLMXD, HMG MD, MXD, HMD, HMXD, SMD, SHMD ND, NXD, HND, HNXD, HNG, SND, SHND CK400N, CK400NN, CM1250HH LC CK800N, CK800NN, CM1600HH CM200HH MH, CK1200N, CK1200NN, CM2500HH LDC, CLDC SGL1, SGL4, SGL6, SGP1, SGP4, SGP6, TBC4, TBC6, TBC8, TKL4V, TKL8S--12S, SKL8, SKP8 TBC8, TKL4V, TKL8S--12S, SKL8, SKP8 HLMD, HLMXD, HMD, HMXD, SHMD HND, HNXD, HNG, SHND TB8 Microversatrip TKL CLD6, HHLD6, HHLXD6, HLD6, SCLD6, SHLD6 CMD6, HMD6, SCMD6, SHMD6 CND6, HND6, SCND6, SHND6 CPD6 MH Series 2 PJ RJ SE (LS Trip), SEH (LS Trip) Tri-Pac NB Tri-Pac PB RDC S6 S7 CJ600 CK1200 * Standard-transition models KCS only [ Programmed-transition models KCP only G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 9 Max. Size, amps 600 800 600 600 800 800 600 800 800 1200 400 600 800 1000 1200 600 600 800 800 1200 800 1200 600 800 1200 1600 1000 1200 1600 2500 800 1600 2500 800 1200 600 1200 Accessories Accessories are available either factory-installed or as loose kits, unless otherwise noted. Accessory Modules The mounting kit holds up to five optional modules. The maximum total current draw is 300 mA. If an External Battery Module is installed, there is no current restriction. Module Current Draw Specifications, mA Alarm Module 75 Standard I/O Module 75 High Power I/O Module 100 - Alarm Module D 90 dB Audible alarm D Any alarm function can be programmed to trigger the audible alarm D Chicago alarm function D Preferred source selection D Supervised transfer control (supervised transfer control switch required) D Connection for external alarm External Alarm Connection Specifications Wire Size #12--22 AWG Cu - Standard Input/Output Module Contact Voltage Rating Inputs Available Inputs 2 Input Definition Contact closure Current 5 mA Max Connection Type Terminal Strip Wire Size #14--24 AWG Max Distance 700 feet Outputs Available 6 Contact Type Form C (SPDT) Contact Voltage Rating 2 A @ 30 VDC 500 mA @ 125 VAC Connection Type Terminal Strip Wire Size #14--24 AWG - High-Power Input/Output Module Input Definition Contact closure Current 5 mA Max Connection Type Terminal Strip Wire Size #14--24 AWG Max Distance 700 feet D Energizes the ATS controls using an external battery when no source power is available D Allows extended engine start time delays D Allows the use of any combination of accessory modules (no current draw restriction, maximum of five modules total) D Connects to one or two batteries, 12 VDC or 24 VDC system D Current draw, 140 mA @ 12 VDC, 86 mA @ 24 VDC D Provides low external battery voltage indication to the transfer switch controller D Reverse-polarity protected Other Accessories Inputs 2 250 mA @ 240 VAC - External Battery Supply Module Outputs Available Inputs 500 mA @ 120 VAC - CSA Certification - Current Sensing Kit D Monitor current on all phases with 1% accuracy - Digital Meter Outputs Outputs Available 3 Contact Type Form C (SPDT) Contact Voltage Rating 12 A @ 24 VDC 12 A @ 250 VAC 10 A @ 277 VAC 2 A @ 480 VAC Connection Type Terminal Strip Wire Size #14--24 AWG Environmental Specifications Temperature --40C to 85C (--40F to 185F) Humidity 35% to 85% noncondensing D Measure and display for both sources: d Voltage d Current d Frequency d Power D Programmable visual alarms: d High voltage d Low voltage d High current D Three digital outputs D Serial port for optional network connections D Password-protected programming menus D Joystick operation D Available factory-installed D See TT-1506, Digital Power Meters G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 10 Accessories, continued - Extended Warranties - Padlockable User Interface Cover D 2-year basic D 5-year basic D 5-year comprehensive D 10-year major components D Standard on NEMA 3R enclosures - Remote Annunciator for ATS D Allows remote monitoring and limited control of up to four transfer switches connected in an RS-485 network D Includes surface and flush mounting provisions - Export Packaging - Seismic Certification - Heater, Anti-Condensation D Humidistat-controlled 120 VAC strip heater (customer-supplied voltage source required) D 125 or 250 watts (sized for enclosure) D Protective 15 Amp circuit breaker - Line-to-Neutral Voltage Monitoring D Monitors all line-to-neutral voltages - Literature Kits D Production literature kit (one kit is included with each transfer switch) D Overhaul literature kit - Load Shed Kit D Forced transfer from Emergency to OFF for programmed-transition models D External hardware is required for the forced transfer to OFF function D Factory-installed D Disconnects power to controller without disconnecting load D Mounts inside the enclosure - Monitor III Software D Monitor and control the power system’s generator sets and transfer switches from a personal computer using a single software package D Monitor and control systems through a Windowsr-based graphical user interface D Monitor and control systems over a local area network, remotely via a modem connection, or through an Ethernet connection D Password-protected data access: Guest, User, and Supervisor levels D Ethernet capability D Start or stop a test from a remote PC D View and adjust trip points, time delays, and system parameters D Assign inputs and outputs D Available as loose kits: d Software kit with serial cable d Software kit with device modem and cables D Available as loose kit for open units ATS Size Enclosure, NEMA Type: Amps 1 3R 4 4X 12 30--1200 B or S D D D D D 1600--2000 F D D 1600--3000 S D D F: Front connections B or S: Standard connections - Supervised Transfer Control Switch D Auto, Manual, and Transfer positions D Automatic and non-automatic modes D Alarm module required - Transient Voltage Surge Suppressor - Logic Disconnect Switch - Neutral Assembly D Certification depends on application and geographic location. Contact your distributor for details. D Available for the transfer switches and enclosures shown below: D TVSS available for the normal source supply D Surge protection reduces transient voltages to harmless levels D Replaceable without disconnecting power D High-performance EMI/RFI filtering: --75dB maximum 100 kHz to 100 MHz D Protection modes: L-L, L-N, L-G, N-G D Thermal and short circuit fusing D LED status indicators D Remote contacts for customer-supplied status indicators Form C (NO, NC, C) 60 W DC, 120 VAC, 3A max. D Audible alarm, 90 dB D Listed to UL 1449, Edition 3 D See additional specifications below TVSS Specifications Limiting Voltage, VAC Working Voltage Ph. Surge Current (Imax), kA 120/240 Split 100 400 470 780 120/208 3 100 400 470 780 120/240 3 100 400/800 470/890 780/1200 277/480 3 100 800 890 1200 220/380 3 100 800 890 1200 240/415 3 100 800 890 1200 G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 11 UL SVR, VAC at 3kAmps at 10kAmp KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KOHLERPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Model Designation Model Mechanism Transition Controls Voltage Poles Enclosure Current Rating Miscellaneous Record the transfer switch model designation in the boxes. The transfer switch model designation defines characteristics and ratings as explained below. Sample Model Designation: KCS-DNTA-0400B Enclosure A: NEMA 1[ B: NEMA 12w C: NEMA 3R] D: NEMA 4w Model K: Kohler Transfer Switch Mechanism C: Standard Transition S: Standard P: Programmed Controls D: MPACt 1500 Microprocessor Controls, Automatic F: MPACt 1500 Microprocessor Controls, Non-Automatic Voltage/Frequency C: 208 Volts/60 Hz D: 220 Volts/50 Hz F: 240 Volts/60 Hz G: 380 Volts/50 Hz H: 400 Volts/50 Hz J: 416 Volts/50 Hz K: 440 Volts/60 Hz M: 480 Volts/60 Hz N: 600 Volts/60 Hz P: 380 Volts/60 Hz R: 220 Volts/60 Hz F: NEMA 4Xw G: Open unit H: NEMA 3R SS ** [ Standard on 30--4000 A models. ] Available to order on 30--3000 A models. Contact the factory for 4000 A units. w Available to order on 30--1000 A models. Contact the factory for larger units. ** NEMA 3R SS available only through special order. Current Rating: Numbers indicate the current rating of the switch in amperes: 0030 (KCS) 0070 (KCS) 0104 (KCS) 0150 0200 (KCS) 0225 (KCP) 0230 (KCS) 0260 0400 0600 0800 1000 1200 1600 2000 2600 3000 4000 ] ] Contact the factory for 4000 amp models. Miscellaneous S: Standard Connections F: Front Connections (optional for 1600 and 2000 Amp models only) B: 260--600 Amp Standard Transition and 150--600 Amp Programmed-transition Number of Poles/Wires N: 2-pole, 3-wire, solid neutral T: 3-pole, 4-wire, solid neutral V: 4-pole, 4-wire, switched neutral W: 4-pole, 4-wire, overlapping neutral Z: 3-pole, 4-wire, integral solid neutral * * Integral solid neutral is mounted on the contactor. Not available on all amperages. DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohlerr Power Systems distributor for availability. 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012, 2013 by Kohler Co. All rights reserved. G11-106 (Model KCS/KCP Transfer Switch) 10/13m Page 12