Download Switching power supply input 22–30 Vac

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ground loop (electricity) wikipedia , lookup

Electrification wikipedia , lookup

Power over Ethernet wikipedia , lookup

Audio power wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Electric power system wikipedia , lookup

Current source wikipedia , lookup

Flip-flop (electronics) wikipedia , lookup

Transformer wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Islanding wikipedia , lookup

Stray voltage wikipedia , lookup

Power engineering wikipedia , lookup

Three-phase electric power wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power inverter wikipedia , lookup

Electrical substation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Distribution management system wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Ground (electricity) wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Voltage regulator wikipedia , lookup

Voltage optimisation wikipedia , lookup

Rectifier wikipedia , lookup

Transformer types wikipedia , lookup

Surge protector wikipedia , lookup

Alternating current wikipedia , lookup

Power electronics wikipedia , lookup

Buck converter wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power supply wikipedia , lookup

Earthing system wikipedia , lookup

Mains electricity wikipedia , lookup

AC adapter wikipedia , lookup

Opto-isolator wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
Switching power supply
input 22–30 Vac
128
• Standard input voltage 24 Vac
• Dissipated power inferior to 10%
• Overload/short circuit protection with automatic restore
• Input protection fuse
• Compact design saves panel space
150
130
55
130
75
Block diagram
BLOCK DIAGRAMS / NOTES
AC
+
+
FILTER
AC
+
AC
AC
+
–
–
AC
AC
+
+
FILTER
AC
+
AC
APPLICATIONS
–
–
PWM
The CABUR power supply units
series CS .../24 with 22 - 30 Vac
input allow transformers with
standard secondary voltage of
24 Vac to be used, more
economical and more readily
available than transformers with
special voltages.
They are suitable for use in SELV
and PELV circuits. In PELV circuits,
in which one safety low voltage
pole has to be earthed, taking
care not to earth the secondary
winding of the transformer too,
but only one pole, normally the
negative, of the 24 Vdc output
of the power supply effectively
used as control voltage.
The earthing together of a
pole of the secondary of the
transformer and a pole of the
24 Vdc of the power supply unit
would inevitably damage the
power supply unit itself.
The purpose of the earthing
connection is to discharge the
interference trapped by the input
filter and must be as short as
possible.
Do not connect the earth terminal
in SELV circuits.
The input and output of the
power supply units in the CS .../24
series are not isolated. The
safety isolation function is
therefore assigned to the external
transformer which has to conform
with the standard CEI 14-6 and/or
EN60742.
+
PWM
VERSIONS
CS624/24
Cod. XAS06VC
CS1224/24
Cod. XAS12VC
INPUT TECHNICAL DATA
Rated voltage
Frequency
Current at lout max
Protection fuse
22 – 30 Vac
50 – 60 Hz
6.6 A
T 10 A
22 – 30 Vac
50 – 60 Hz
13.2 A
T 16 A (inside mounted)
24 Vdc adjustable ± 8%
8A
6A
<1%
< 100 mVpp
> 15 ms
Hiccup circuit, auto reset
–
–
24 Vdc adjustable ± 8%
14 A
12 A
<1%
< 100 mVpp
> 15 ms
Hiccup circuit, auto reset
–
–
≥ 90%
< 16 W
-10 – 60°C, -0.2 A/°C over 45°C
–
–
0.5 kVac / 60 s
IP 20
–
EN 50081-1, EN 50082-2
varistor - 4.5 kA 8/20 in input
terminal blocks 2.5 mm2, pluggable
metallic
0.7 kg ca.
vertical on rail, allow 20 mm spacing
between adjacent components
PR/3/AC - PR/3/AS
≥ 90%
< 32 W
-10 – 50°C, -0.5 A/°C over 45°C
–
–
0.5 kVac / 60 s
IP 20
–
EN 50081-1, EN 50082-2
varistor - 4.5 kA 8/20 in input
terminal blocks 2.5 mm2, pluggable
metallic
0.9 kg ca.
vertical on rail, allow 20 mm spacing
between adjacent components
PR/3/AC - PR/3/AS
–
–
OUTPUT TECHNICAL DATA
Voltage
Maximum current
Continuous current
Load regulation
Ripple at lout max
Hold up time
Overload/short circuit protection
Output signal
Parallel connection
APPROVALS
GENERAL TECHNICAL DATA
Efficiency
Dissipated power
Operating temperature
Input / output isolation
Input / ground isolation
Output / ground isolation
Protection degree
Standard / Approvals
EMC standards
Surge immunity
Connection terminal blocks
Housing material
Approximate weight
Mounting information
Mounting rail
according to IEC60715/TH35
Mounting rail
according to IEC60715/G32