Download Appendix B Safe Work Practices • Only Qualified High Voltage

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Ohm's law wikipedia , lookup

Power engineering wikipedia , lookup

Electronic engineering wikipedia , lookup

Mechanical-electrical analogies wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Electrical substation wikipedia , lookup

Alternating current wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Metadyne wikipedia , lookup

Electrical engineering wikipedia , lookup

Electrical connector wikipedia , lookup

Telecommunications engineering wikipedia , lookup

Voltage optimisation wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Earthing system wikipedia , lookup

Electrician wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Stray voltage wikipedia , lookup

Ground (electricity) wikipedia , lookup

National Electrical Code wikipedia , lookup

Mains electricity wikipedia , lookup

Portable appliance testing wikipedia , lookup

Transcript
UC Irvine – High Voltage Electrical Safety Program
Appendix B
Safe Work Practices
General Safety Requirements
•
•
•
•
Only Qualified High Voltage Electrical Workers shall be permitted to
work on energized electrical circuitry (50 volts/25 amps) to ground or
greater.
Permanent modifications (such as guards, barriers, interlocks, voltage
dividers, etc.) shall be implemented on any piece of equipment,
machine or system, which has exposed electrical circuitry greater than
50 volts/25 amps to prevent accidental contact by personnel during
normal operation, service, or maintenance activities.
Where modifications cannot be made, temporary barriers, signs, or
other alerting means shall be used to protect associates when
permanent guards or other safety systems must be removed or
deactivated to complete the documented maintenance or test
procedure.
Personnel performing energized electrical work should be alert,
concentrate on the work being performed, and be aware of grounded
objects and their proximity to hands, arms, legs, and feet.
-Personnel should not talk unnecessarily while performing
energized electrical work, and should proceed with the work to be
done in a safe manner.
-Loose wire ends should be protected with wire nuts while
performing energized electrical work. Energized equipment must
never be left open or exposed while unattended.
-When possible, employees should perform energized electrical
work following the “One Hand Rule”. This requires the employee
to place one hand in a pocket to prevent contact with grounded
work surfaces while performing energized electrical work and to
prevent electrical current from flowing through the heart.
Cord and Plug Connected Equipment
The following work practices should be followed whenever performing work
using cord and plug-connected equipment, including extension cords.
• Visual inspection of the cord and plug should be performed before
starting work.
Defective or damaged items must be removed
immediately from use, and may not be used until repairs and tests
necessary to render the equipment safe have been made.
• All extension cords must be rated for their intended use.
• Extension cords used with grounded equipment must contain a
grounding conductor. Adapters that interrupt the continuity of the
equipment grounding connection may not be used.
1
UC Irvine – High Voltage Electrical Safety Program
•
Equipment provided with a GFCI should be tested using the test
function of the GFCI before starting work, to ensure that ground fault
protection is present. Equipment is not to be used if the GFCI is found
to be defective.
• Equipment should be handled in a manner that will not cause damage
to the cord and plug. Cords are not to be used for raising or lowering
equipment, and should not be fastened with staples or hung in a
fashion that could damage the outer jacket or insulation.
• Cords should be routed so that they do not present a trip hazard in
aisles and workspaces.
Workers’ hands shall be dry when plugging and unplugging cord and plug connected
equipment and extension cords. Locking connectors should be properly secured after
connection.