* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download the AJ717A-C Datasheet
Fault tolerance wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Control system wikipedia , lookup
Wireless power transfer wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Audio power wikipedia , lookup
Buck converter wikipedia , lookup
Power over Ethernet wikipedia , lookup
Stray voltage wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Rectiverter wikipedia , lookup
Mains electricity wikipedia , lookup
PROLABS – AJ717A-C 8.5GGBd SFP+ LR Transceiver AJ717A-C Overview PROLABS’s AJ717A-C SFP+ optical transceivers are based on Fiber Channel Links up to 8.5Gb/s data rate over multimode fiber, and they are compliant with PC-PI-4 Rev 7.0 and SFF-8472 Rev 10.1 and compatible with SFF-8432 and applicable portions of SFF-8431 Rev 1.3. Product Features Up to 8.5 GBd bi-directional data links Compliant with SFF8431 & SFF8432 Hot-pluggable SFP+ footprint 1310nm DFB laser transmitter Duplex LC connector Built-in digital diagnostic functions Up to 10km on SMF Single power supply 3.3V RoHS Compliance Operating temperature range: 0℃ to 70℃. Applications 2.125G Fiber Channel 4.24G Fiber Channel 8.5G Fiber Channel Ordering Information Part Number AJ717A-C General Specifications Parameter Data Rate Bit Error Rate Operating Temperature Storage Temperature Supply Current Input Voltage Maximum Voltage Link Distances Parameter 10.3125 GBd Description 8.5G SFP+ 1310nm LC Connectors 10km on SMF, with DOM function. Symbol Min DR BER TOP TSTO IS VCC VMAX Typ Max 10.3125 0 40 3 0.5 230 3.3 Fiber Type 9/125um SMF Unit GBd 1012 70 85 260 3.6 4 ℃ ℃ mA V V Remarks IEEE 802.3ae Case temperature Ambient temperature For electrical power interface For electrical power interface Distance Range (Km) 10 Optical Characteristics – Transmitter VCC=3V to 3.6V, TC=0℃ to 70℃ Parameter Symbol Output Optical Power PTX Optical Center Wavelength C OMA Optical Modulation Amplitude Spectral Width SMSR Side Mode Suppression Ratio RIN Relative Intensity Noise TDP Transmitter Dispersion Penalty Transmitter Jitter Launch Power of OFF POUT_OFF Transmitter Optical Characteristics – Receiver VCC=3V to 3.6V, TC=0℃ to 70℃ Parameter Optical Center Wavelength Optical Input Power Receiver Sensitivity (OMA)@ 2.125GBd Symbol C PIN RX_SEN1 Min 8.4 1260 290 Typ Unit Remarks dBm Average nm uW Per IEEE 802.3ae 1 nm 30 dB dB/Hz 128 3.2 dB According to IEEE 802.3ae requirement Min 1260 -14.4 Max 0.5 1355 Typ – 30 dBm Max 1600 0.5 0.015 Unit nm dBm mW Receiver Sensitivity (OMA)@ 10.3GBd RX_SEN2 0.029 mW Receiver Sensitivity (OMA)@ 10.3GBd RX_SEN3 0.042 mW Return Loss LOS Assert LOS De-Assert LOS Hysteresis RL LOSA LOSD – 19 0.5 Electrical Characteristics – Transmitter VCC=3V to 3.6V, TC=0℃ to 70℃ Parameter Symbol RIN Input differential impedance VIN_PP Single ended data input swing VD Transmit disable voltage VEN Transmit enable voltage Electrical Characteristics – Receiver VCC=3V to 3.6V, TC=0℃ to 70℃ Parameter Single ended data output swing Data output rise/fall time @ 2.125G & 4.25G Data output rise/fall time @ 8.5G LOS Fault LOS Normal 12 – 30 Min Typ 100 90 2 VEE Symbol VOUT_PP TR /TF TR /TF VLOS_Fault VLOS_normal Max 350 VCC VEE+0.8 Min 185 2 VEE Typ 300 Average Remarks Average, Informative Measured with worst ER: -12 31 BER<10 2 -1 PRBS Measured with worst ER: -12 31 BER<10 2 -1 PRBS Measured with worst ER: -12 31 BER<10 2 -1 PRBS dB dBm dBm dB Unit Ω mV V V Max 425 120 60 VCC_HOST VEE+0.5 Remarks Non condensing Unit mV ps ps V V Remarks Digital Diagnostic Functions AJ717A-C support the 2-wire serial communication protocol as defined in the SFF 8472. Digital diagnostic information are accessible over the 2-wire interface at the address 0xA2. Digital Diagnostics for AJ717A-C are internally calibrated by default. A micro controller unit inside the transceiver gathers the monitoring information and reports the status of transceiver. Transceiver Temperature, internally measured, represented as a 16 bit signed twos complement value in increments of 1/256 degrees Celsius, Temperature accuracy is better than ±3 degrees Celsius over specified operating temperature and voltage. Transceiver Supply Power, internally measured, represented as a 16 bit unsigned integer with the voltage defined as the full 16 bit value (0 – 65535) with LSB equal to 100 µVolt, yielding a total range of 0 to +6.55 Volts. Transceiver TX bias current, internally measured, represented as a 16 bit unsigned integer with the current defined as the full 16 bit value (0 – 65535) with LSB equal to 2 µA, yielding a total range of 0 to 131mA. Accuracy is better than ±10% over specified operating temperature and voltage. Transceiver TX output power, internally measured, represented as a 16 bit unsigned integer with the power defined as the full 16 bit value (0 – 65535) with LSB equal to 0.1 µW. Data is assumed to be based on measurement of laser monitor photodiode current. Accuracy is better than ±3dB over specified temperature and voltage. Data is not valid when the transmitter is disabled. Transceiver RX received optical power, internally measured, represented as a 16 bit unsigned integer with the power defined as the full 16 bit 35 value (0 – 65535) with LSB equal to 0.1 µW. Accuracy is better than ±3dB over specified temperature and voltage. Parameter Temperature Voltage Bias Current Tx Power Rx Power Symbol Accuracy TMON VMON IMON PMON PMON ±3 ±0.1 ±10 ±3 ±3 Units Report Range Internal Calibration ℃ 85 10 V 2.9 3.7 % 1 60 dB 0 8 dB 0 16 Unit ℃ V mA dBm dBm Remarks Block Diagram of Transceiver TX_FAULT TX_DISABLE TX_DATA TX_DATA\ RX_DATA RX_DATA\ ELECTRICAL OPTICAL SUBASSEMBLY SUBASSEMBLY Safety Control LD Driver Limiting Amp LOS Detect DUPLEX LC RECEPTACL E RX_LOS SDA SCL MOD_ABS Micro Controller MOD DEF PRE AMP OPTICAL SUBASSEMBLY Transmitter Section The VCSEL driver accept differential input data and provide bias and modulation currents for driving a laser. An automatic power-control (APC) feedback loop is incorporated to maintain a constant average optical power.1310 DFB in an eye safe optical subassembly (OSA) mates to the fiber cable. TX_DISABLE The TX_DISABLE signal is high (TTL logic “1”) to turn off the laser output. The laser will turn on within 1ms when TX_DISABLE is low (TTL logic “0”). TX_FAULT When the TX_FAULT signal is high, output indicates a laser fault of some kind. Low indicates normal operation. Receiver Section The receiver utilizes a PIN detector integrated with a trans-impedance preamplifier in an OSA. This OSA is connected to a Limiting Amplifier which providing post-amplification quantization, and optical signal detection. The limiting Amplifier is AC-coupled to the transimpedance amplifier, with internal 100Ω differential termination. Receive Loss (RX_LOS) The RX_LOS is high (logic “1”) when there is no incoming light from the companion transceiver. This signal is normally used by the system for the diagnostic purpose. The signal is operated in TTL level. Controller Section The micro controller unit monitors the operation information of LD driver and Limiting Amplifier. And report these status to the customer. Dimensions ALL DIMENSIONS ARE ±0.2mm UNLESS OTHERWISE SPECIFIED UNIT: mm PCB Layout Recommendation Electrical Pad Layout Towards ASIC 20 11 10 1 Towards Bezel Pin Assignment PIN # Symbol Description 1 VEET 2 TFAULT 3 TDIS Transmitter Disable. Laser output disable on high or open 4 SDA Data line for serial ID 5 SCL Clock line for serial ID 6 MOD_ABS 7 8 RS0 LOS 9 10 11 12 13 RS1 VEER VEER RD– RD+ No connection required Loss of Signal indication. Logic 0 indicates normal operation No connection required Receiver ground (common with transmitter ground) Receiver ground (common with transmitter ground) Receiver Inverted DATA out. AC coupled Receiver Non-inverted DATA out. AC coupled 14 VEER Receiver ground (common with transmitter ground) 15 16 VCCR VCCT Receiver power supply Transmitter power supply 17 VEET Transmitter ground (common with receiver ground) 18 19 TD+ TD– Transmitter Non-Inverted DATA in. AC coupled Transmitter Inverted DATA in. AC coupled 20 VEET Transmitter ground (common with receiver ground) Transmitter ground (common with receiver ground) Remarks Circuit ground is isolated from chassis ground Transmitter Fault. Disabled: TDIS>2V or open Enabled: TDIS<0.8V Should Be pulled up with 4.7k – 10k ohm on host board to a voltage between 2V and 3.6V Module Absent. Grounded within the module LOS is open collector output Circuit ground is isolated from chassis ground Circuit ground is isolated from chassis ground Circuit ground is connected to chassis ground Circuit ground is connected to chassis ground References 1. IEEE standard 802.3ae. IEEE Standard Department, 2005. 2. Enhanced 8.5 and 10 Gigabit Small Form Factor Pluggable Module “SFP+” – SFF-8431 3. Digital Diagnostics Monitoring Interface for Optical Transceivers – SFF-8472.