* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download LED BUILT-IN MODULES
Opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Stray voltage wikipedia , lookup
Mains electricity wikipedia , lookup
Surge protector wikipedia , lookup
LUGA C 2016 – COB modules for lumen packages up to 1000 lm LED BUILT-IN MODULES LUGA C 2016 500 lm TO 1000 LM LUGA C 2016 COB MODULES FOR LUMEN PACKAGES UP TO 1000 LM DMC122***F Typical Applications • Integration in reflector luminaires • Flat surface-mounting luminaires • Downlights • Residential lighting • Furniture lighting • Stairway and corridor illumination LUGA C 2016 ¢ LONG SERVICE LIFETIME: 50,000 HOURS (L90; B10) ¢ HIGHLY EFFICIENT: UP TO 140 LM/W AT tp = 65 °C ¢ NARROW COLOUR TOLERANCES: 3 STEP MACADAM (INITIAL) 4 STEP MACADAM SHIFT (AFTER 50,000 HRS) ¢ HIGH ELECTRICAL ISOLATION DUE TO CERAMIC COB TECHNOLOGY ¢ SMALL SHAPE A Member of the Panasonic Group Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com LUGA C 2016 – COB modules for lumen packages up to 1000 lm LUGA C 2016 – 500 lm to 1000 lm Technical Notes • Dimensions: 13.5x13.5x1.7 mm • Light emitting surface (LES): Ø 8 mm • Use of external LED constant current driver Electrical Characteristics at tp = 65 °C Ref. No. Type DMC122***F Typ. voltage DC All Types Temperature Typ. power consumption 150 mA 200 mA 250 mA coefficient 150 mA 200 mA V V V mV/K W W W 34.4 35.2 35.8 –18 5.2 7 9 250 mA Voltage and power tolerance: ±10 % Maximum Ratings Exceeding the maximum ratings can lead to reduction of service life or destruction of the modules. Type DMC122** *F Operating Operation temperature Ambient temperature Storage temperature current range at tc point range range mA °C min. °C max. °C min. °C max. °C min. °C max. mA 200 –40 +105 –40 +40 –40 +105 360 250 Max. allowed repetitive peak current +100 Optical Characteristics at tp = 65 °C Ref. No. Type Colour Correlated colour Typ. luminous flux** and efficiency at temperature* 150 mA K lm lm/W lm lm/W 200 mA Typ. beam 250 mA lm Typ. CRI angle lm/W ° Photometric code Ra DMC122C27F 560392 warm white 2700 650 125 830 119 995 111 120 82 827/349 DMC122C30F 560394 warm white 3000 705 136 900 129 1080 120 120 85 830/349 DMC122C35F 560395 neutral white 3500 710 137 905 129 1085 121 120 85 835/349 DMC122C40F 560396 neutral white 4000 725 139 925 132 1105 123 120 85 840/349 DMC122C50F 560397 cool white 5000 730 140 935 134 1120 124 120 85 850/349 * Colour tolerance: 3 MacAdam | ** Production tolerance of luminous flux and efficiency: ± 10 % | Min. CRI Ra: > 80 Minimum order quantity: 225 pcs. Operating Life at tp = 65 °C LUGA C 2016 – 500 lm to 1000 lm_GB 2/5 February, 2016 Lumen DMC122***F maintenance IF 150 mA IF 200 mA IF 250 mA L90/B10 56,000 hrs. 50,000 hrs. 45,000 hrs. L80/B10 81,000 hrs. 75,000 hrs. 70,000 hrs. L70/B10 91,000 hrs. 85,000 hrs. 80,000 hrs. The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification. A Member of the Panasonic Group Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com 2 LUGA C 2016 – COB modules for lumen packages up to 1000 lm LUGA C 2016 – 500 lm to 1000 lm Typical Light Distribution Curve I (cd/klm) 90° 85 170 60° 255 340 30° Mechanical Dimensions Product Code • The clearance and creepage distances are designed for working voltages up to 240 V DC (basic insulation) and 60 V DC (reinforced insulation). • Thickness of PCB is included in calculation. DMC122***F 13.5±0.3 Ø10 13.5±0.3 LES (Ø8) 1±0.1 1.7 TS (Ø1) CCT CRI 2700K 82 No. DMC122 22C27F 3000K 85 22C30F 3100K** 85 22C31F 3500K 85 22C35F 4000K 85 22C40F 5000K 85 22C50F 2700K* 95 22S27F 3000K* 95 22S30F 3100K** 95 22S31F 3500K* 95 22S35F 4000K* 95 22S40F *Below BBL **Pearl White LUGA C 2016 – 500 lm to 1000 lm_GB 3/5 February, 2016 Bins Measurement tolerance x/y: ± 0.005 The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification. A Member of the Panasonic Group Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com 3 LUGA C 2016 – COB modules for lumen packages up to 1000 lm LUGA C 2016 – 500 lm to 1000 lm Assembly and Safety Information LUGA C 2016 – 500 lm to 1000 lm_GB 4/5 February, 2016 Installation must be carried out under observation of the relevant regulations and standards. The LED modules are designed for operation within a casing or luminaire. Installation must be carried out in a voltage-free state (i.e. disconnection from the mains). The following advice must be observed; non-observance can result in the destruction of the LED assembly modules, fire and/or other hazards. • ESD (electrostatic discharge) protection measures must be observed when handling and installing the LED modules. See VS's application notes on ESD protection. • LED assembly modules must not be subjected to any undue mechanical stress, e. g.: – do not treat as bulk cargo – avoid shear and compressive forces during handling and installation – do not damage circuit paths – do not touch the yellow phosphorus layer • The module must be fixed onto a thermally conductive surface. • The electrical connection of the modules must be done with separate holder systems. Direct soldering of cables at the contact pads is not allowed. • Safe operation only possible by the use of external constant current sources (Imax. see table "Electrical Characteristics"). • Operation only with power supply units that feature the following protection: – Short-circuit protection – Overload protection – Overheating protection – SELV (Safety Extra Low Voltage); Umax. £ 60 V – Imax. (see table "Maximum Ratings") must not be exceeded. • When operating devices will be selected care has been taken to ensure that the maximum values (see table "Maximum Ratings") will not be exceeded. • Please ensure the correct polarity of the leads prior to commissioning. Reversed polarity can destroy the modules. • Safety regulations acc. to EN 60598 (or further standards) has to be observed if the maximum output voltage exceed the permitted touchable value. • Measurement tolerances: – luminous flux: ± 7 % – voltage: ± 3 % – CRI: ± 1 % • A parallel connection of the modules is not allowed. • To ensure problem-free operation, the specified maximum temperature at the tc point (see "Operating Life") must be observed (and measured in accordance with EN 60598-1). To satisfy this point, it may be necessary to put measures in place to ensure any heat is dissipated from the PCB to the environment. • In the event of outdoor applications or applications in damp locations, care must be taken to protect LED assembly modules against humidity, splashes and jets of water. Any corrosion damage resulting from humidity or contact with condensation will not be recognised as a defect or manufacturing fault. LED assembly modules are not specially protected against foreign bodies or dust. Depending on the type of application, further protection must be ensured to prevent dust and foreign bodies from entering. • Operating LED modules in the presence of certain chemical substances or in chemically enriched (aggressive) environments can impair module functionality or even cause total module failure. Detailed information can be found in our "Chemical Incompatibility" PDF on our website www.vossloh-schwabe.com • The photobiological safety of the LED modules must be classified into risk groups in accordance with EN 62471: 2008. – general lighting exempt group: DMC122***F – other applications risk group 1: DMC122***F The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification. A Member of the Panasonic Group Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com 4 LUGA C 2016 – COB modules for lumen packages up to 1000 lm Accessories LUGA C Holder For LED PCB LUGA C Fixation: Fixing holes for screws M3 Recommended torque: 0.4 Nm Push-in terminals for AWG18, AWG20, AWG22, solid or tin-plated stranded leads 2x M3 Ø 39 20 LUGA C 2016 – 500 lm to 1000 lm_GB 5/5 February, 2016 4.25 26 34.9 6.5 13 LUGA C Holder Material: plastic Dimensions (LxWxH): 34.9 x 26 x 4.25 mm Type: 180414-1112 Ref. No.: 555771 10 Ø12.2 The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification. A Member of the Panasonic Group Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com 5