LUGA C 2016 – COB modules for lumen packages up to 1000 lm
LED BUILT-IN
MODULES
LUGA C 2016
500 lm TO 1000 LM
LUGA C 2016
COB MODULES FOR LUMEN
PACKAGES UP TO 1000 LM
DMC122***F
Typical Applications
• Integration in reflector luminaires
• Flat surface-mounting luminaires
• Downlights
• Residential lighting
• Furniture lighting
• Stairway and corridor illumination
LUGA C 2016
¢ LONG SERVICE LIFETIME: 50,000 HOURS (L90; B10)
¢ HIGHLY EFFICIENT: UP TO 140 LM/W AT tp = 65 °C
¢ NARROW COLOUR TOLERANCES:
3 STEP MACADAM (INITIAL)
4 STEP MACADAM SHIFT (AFTER 50,000 HRS)
¢ HIGH ELECTRICAL ISOLATION DUE TO
CERAMIC COB TECHNOLOGY
¢ SMALL SHAPE
A Member of the Panasonic Group
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
LUGA C 2016 – COB modules for lumen packages up to 1000 lm
LUGA C 2016 – 500 lm to 1000 lm
Technical Notes
• Dimensions: 13.5x13.5x1.7 mm
• Light emitting surface (LES): Ø 8 mm
• Use of external LED constant current driver
Electrical Characteristics
at tp = 65 °C
Ref. No.
Type
DMC122***F
Typ. voltage DC
All Types
Temperature
Typ. power consumption
150 mA
200 mA
250 mA
coefficient
150 mA
200 mA
V
V
V
mV/K
W
W
W
34.4
35.2
35.8
–18
5.2
7
9
250 mA
Voltage and power tolerance: ±10 %
Maximum Ratings
Exceeding the maximum ratings can lead to reduction of service life or destruction of the modules.
Type
DMC122** *F
Operating
Operation temperature
Ambient temperature
Storage temperature
current
range at tc point
range
range
mA
°C min.
°C max.
°C min.
°C max.
°C min.
°C max.
mA
200
–40
+105
–40
+40
–40
+105
360
250
Max. allowed
repetitive peak current
+100
Optical Characteristics
at tp = 65 °C
Ref. No.
Type
Colour
Correlated colour
Typ. luminous flux** and efficiency at
temperature*
150 mA
K
lm
lm/W
lm
lm/W
200 mA
Typ. beam
250 mA
lm
Typ. CRI
angle
lm/W
°
Photometric
code
Ra
DMC122C27F
560392
warm white
2700
650
125
830
119
995
111
120
82
827/349
DMC122C30F
560394
warm white
3000
705
136
900
129
1080
120
120
85
830/349
DMC122C35F
560395
neutral white
3500
710
137
905
129
1085
121
120
85
835/349
DMC122C40F
560396
neutral white
4000
725
139
925
132
1105
123
120
85
840/349
DMC122C50F
560397
cool white
5000
730
140
935
134
1120
124
120
85
850/349
* Colour tolerance: 3 MacAdam | ** Production tolerance of luminous flux and efficiency: ± 10 % | Min. CRI Ra: > 80
Minimum order quantity: 225 pcs.
Operating Life
at tp = 65 °C
LUGA C 2016 – 500 lm to 1000 lm_GB 2/5 February, 2016
Lumen
DMC122***F
maintenance IF 150 mA
IF 200 mA
IF 250 mA
L90/B10
56,000 hrs.
50,000 hrs.
45,000 hrs.
L80/B10
81,000 hrs.
75,000 hrs.
70,000 hrs.
L70/B10
91,000 hrs.
85,000 hrs.
80,000 hrs.
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
A Member of the Panasonic Group
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
2
LUGA C 2016 – COB modules for lumen packages up to 1000 lm
LUGA C 2016 – 500 lm to 1000 lm
Typical Light Distribution Curve
I (cd/klm)
90°
85
170
60°
255
340
30°
Mechanical Dimensions
Product Code
• The clearance and creepage distances are
designed for working voltages up to 240 V DC
(basic insulation) and 60 V DC (reinforced
insulation).
• Thickness of PCB is included in calculation.
DMC122***F
13.5±0.3
Ø10
13.5±0.3
LES (Ø8)
1±0.1
1.7
TS
(Ø1)
CCT
CRI
2700K
82
No.
DMC122
22C27F
3000K
85
22C30F
3100K** 85
22C31F
3500K
85
22C35F
4000K
85
22C40F
5000K
85
22C50F
2700K*
95
22S27F
3000K*
95
22S30F
3100K** 95
22S31F
3500K*
95
22S35F
4000K*
95
22S40F
*Below BBL
**Pearl White
LUGA C 2016 – 500 lm to 1000 lm_GB 3/5 February, 2016
Bins
Measurement tolerance x/y: ± 0.005
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
A Member of the Panasonic Group
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
3
LUGA C 2016 – COB modules for lumen packages up to 1000 lm
LUGA C 2016 – 500 lm to 1000 lm
Assembly and Safety Information
LUGA C 2016 – 500 lm to 1000 lm_GB 4/5 February, 2016
Installation must be carried out under observation of the relevant regulations and standards. The LED modules are designed for operation within
a casing or luminaire. Installation must be carried out in a voltage-free
state (i.e. disconnection from the mains). The following advice must be
observed; non-observance can result in the destruction of the LED
assembly modules, fire and/or other hazards.
• ESD (electrostatic discharge) protection measures must be observed
when handling and installing the LED modules. See VS's application
notes on ESD protection.
• LED assembly modules must not be subjected to any undue mechanical stress, e. g.:
– do not treat as bulk cargo
– avoid shear and compressive forces during handling and
installation
– do not damage circuit paths
– do not touch the yellow phosphorus layer
• The module must be fixed onto a thermally conductive surface.
• The electrical connection of the modules must be done with separate
holder systems. Direct soldering of cables at the contact pads is not
allowed.
• Safe operation only possible by the use of external constant current
sources (Imax. see table "Electrical Characteristics").
• Operation only with power supply units that feature the following
protection:
– Short-circuit protection
– Overload protection
– Overheating protection
– SELV (Safety Extra Low Voltage); Umax. £ 60 V
– Imax. (see table "Maximum Ratings") must not be exceeded.
• When operating devices will be selected care has been taken to ensure that the maximum values (see table "Maximum Ratings") will not be
exceeded.
• Please ensure the correct polarity of the leads prior to commissioning.
Reversed polarity can destroy the modules.
• Safety regulations acc. to EN 60598 (or further standards) has to be
observed if the maximum output voltage exceed the permitted touchable value.
• Measurement tolerances:
– luminous flux: ± 7 %
– voltage: ± 3 %
– CRI: ± 1 %
• A parallel connection of the modules is not allowed.
• To ensure problem-free operation, the specified maximum temperature
at the tc point (see "Operating Life") must be observed (and measured
in accordance with EN 60598-1). To satisfy this point, it may be
necessary to put measures in place to ensure any heat is dissipated
from the PCB to the environment.
• In the event of outdoor applications or applications in damp locations,
care must be taken to protect LED assembly modules against
humidity, splashes and jets of water. Any corrosion damage resulting
from humidity or contact with condensation will not be recognised as a
defect or manufacturing fault. LED assembly modules are not
specially protected against foreign bodies or dust. Depending on the
type of application, further protection must be ensured to prevent dust
and foreign bodies from entering.
• Operating LED modules in the presence of certain chemical substances or in chemically enriched (aggressive) environments can
impair module functionality or even cause total module failure.
Detailed information can be found in our "Chemical Incompatibility"
PDF on our website www.vossloh-schwabe.com
• The photobiological safety of the LED modules must be classified into
risk groups in accordance with EN 62471: 2008.
– general lighting
exempt group: DMC122***F
– other applications
risk group 1: DMC122***F
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
A Member of the Panasonic Group
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
4
LUGA C 2016 – COB modules for lumen packages up to 1000 lm
Accessories
LUGA C Holder
For LED PCB LUGA C
Fixation: Fixing holes for screws M3
Recommended torque: 0.4 Nm
Push-in terminals for AWG18, AWG20, AWG22,
solid or tin-plated stranded leads
2x M3
Ø 39
20
LUGA C 2016 – 500 lm to 1000 lm_GB 5/5 February, 2016
4.25
26
34.9
6.5
13
LUGA C Holder
Material: plastic
Dimensions (LxWxH): 34.9 x 26 x 4.25 mm
Type: 180414-1112
Ref. No.: 555771
10
Ø12.2
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
A Member of the Panasonic Group
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
5