Download Interface Components - Components for REGSys

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Transformer wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Power inverter wikipedia , lookup

Islanding wikipedia , lookup

Power engineering wikipedia , lookup

Fault tolerance wikipedia , lookup

Electrical substation wikipedia , lookup

Printed circuit board wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

History of electric power transmission wikipedia , lookup

Stray voltage wikipedia , lookup

Transformer types wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Three-phase electric power wikipedia , lookup

Rectifier wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Power electronics wikipedia , lookup

Electronic paper wikipedia , lookup

Surge protector wikipedia , lookup

Metadyne wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Rectiverter wikipedia , lookup

Voltage regulator wikipedia , lookup

Mains electricity wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Surface-mount technology wikipedia , lookup

Transcript
Interface Components Components for REGSys™
„Do you know the tap position of your transformer?“
Listing of the tap changer position of a transformer
with the interface component REG - X
Application
Available Interface components
Approved Codes
The interface components
of REG - X, components of
the voltage regulator system REGSys, are representing the tap changer
position of the transformer
by a commonly used BCDcode and are used depending upon the task to match
the BCD - input of a
• voltage regulator
• digital display
• remote control system
The interface components REG - X can be
connected to the following rails:
• Row of contacts with 1 to n switches
(For each tap position only the corresponding switch is closed. The realization is performed by a matrix of diodes).
• Row of contacts with m to n switches
(For each tap position a defined combination of switches is closed).
• Row of resistances
(Resistance value is proportional to the
tap changer position. Measuring circuit:
3- or 4- wire circuit; matching range
5 Ω to 50 Ω or as indicared).
• Direct current in mA
(mA value is proportional to the tap
changer position)
• BCD
(Binary coded decimal code)
If the tap changer sends already coded
signals the following codes are approved:
• Binary-Code
• BCD-Code
• Gray-Code
• AWZ-Code (Albis-Werke-Zürich)
Output Signals
Depending upon the version the interface
components REG - X are equipped with
one or two outputs.
• Output 1:
BCD-Code for regulator RE G- D
• Output 2:
BCD-Code for remote digital display
Power: AC 230 V, 2 A
DC 220 V, 150 W
Binary Code if requested
Display / Range
For the display of a tap changer position
the assignment of the zero-position to
any tap changer position can be selected.
• Display unipolar without sign
• Display bipolar with sign
Resistance 0,5 ... 50 Ω / tap position
1 to 32 (–15...0...15)
Binary-Code
BCD-Code
AWZ (Albis-Werke-Zürich)-Code
Gray-Code
Designs
Electromagnetic Compatibility
Power supply
In respect to the specification for mounting, electric safety, protection and climatic
environment the following designs are
available:
• Wall-mounting case
(with built in display) Dimensions:
l x w x h [mm] 205 x 130 x 106
• Modular case (with built in display)
Dimensions:
w x h x d [mm] 144 x 72 x 210
• Rack version (without display,
display at REG - D) Width: 8 TE
The equipment complies with the specifications of electromagnetic radiation and
electromagnetic stability according to the
test conditions EN 55011: 1991;
EN 50082-1: 1995; EN 50082-2: 1995
The interface components can be powered either via a built in AC or DC power
supply with galvanic isolation or with an
external AC or DC voltage.
Temperature Range
Power supply
Operation
Case versions
0°C ... + 55°C
Rack mounting
0°C ... + 65°C
Transport and storage – 25°C ... + 85°C
A
B
AC
85 V ... 264 V
20 V ... 60 V
DC
88 V ... 280 V
18 V ... 72 V
≤ 12 W
≤ 12 W
Power
consumption
Specifications and Standards
BCD-Code (Example)
IEC 1010/EN 61010 (VDE 0411)
CANICSA-C22.2No.1010.1 -92
VDE 0110
ICE 2554
ICE 529 BS 5490
EN 50178/VDE 0160/11.94 (draft)
VDE 0106 Part 100
Tap
changer
position
1
2
3
4
5
6
7
8
9
10
11
19
20
21
30
31
32
33
SCADA-System
REG - D
Display
unipolar
Display
bipolar
20
10
8
4
2
1
Total
1
2
3
4
5
6
7
8
9
10
11
19
20
21
30
31
32
33
+ 19
+ 18
+ 17
+ 16
+ 15
+ 14
+ 13
+ 12
+ 11
+ 10
+9
+1
0
–1
– 10
– 11
– 12
– 13
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
1
1
0
0
1
1
1
1
0
0
0
0
0
0
0
1
1
0
0
1
0
0
0
0
0
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
0
0
0
0
0
0
0
0
1
1
1
0
1
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
1
2
2+1
4
4+1
4+2
4+2+1
8
8+1
10
10+1
10+8+1
20
20+1
30
30+1
30+2
30+2+1
Fax - Reply
Name
Company
Street
a.eberle gmbh
Meß- und Regeltechnik
D -90441 Nürnberg
Fax no. +49/911/666664
❑ I/we wish to receive further information
about your delivery program
❑ Resonance regulator REG - DE
❑ ground-fault-tracing in
❑
❑
❑
❑
inductively grounded medium
voltage networks
ground current relay
three-phase calibrators
components for the supervision
of the net quality
analogue function modules
Town
Phone no.
Fax no.
❑ I/we wish to receive more detailed information
and/or an offer on:
Description
Type
Voltage regulator
REG - D
Voltage regulator
SR192 - D
Monitoring Unit
PAN - D
Monitoring Unit
PAN - A
Multi Transducer
MMU - D
Interface Components
ANA - D
❑ I/we wish to receive information
Data sheet
Offer
BIN - D
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
REG - X
❑
❑
❑
❑
❑
❑
on your training courses / workshops
❑ I/we wish to receive your customer
Interface Components
information letters (technical reports)
❑ I/we wish to arrange a personal
demonstration / project meeting
Accessories
E - LAN-star distributor
REG - ST
E - LAN-booster
REG - BO
E - LAN PC-adapter
REG - PC
❑
❑
❑
triple E - LAN PC-adapter
without star distributor,
with booster
REG - PC-3
❑
a. eberle gmbh
Aalener Straße 30/32
D -90441 Nürnberg
Phone no.+49/911/628108-0
Fax no. +49/911/666664
E-mail: [email protected]
www.a-eberle.de / www.regsys.de