* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Shield mini 40W Temperature Control
Wireless power transfer wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Standby power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrification wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electric power system wikipedia , lookup
Voltage optimisation wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Power inverter wikipedia , lookup
Power over Ethernet wikipedia , lookup
Mains electricity wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power engineering wikipedia , lookup
Audio power wikipedia , lookup
Alternating current wikipedia , lookup
Control system wikipedia , lookup
Power supply wikipedia , lookup
Buck converter wikipedia , lookup
75 Watt Variable Power Module with Temperature Protection Pluto 26650 is a power regulated digital switch-mode DC-DC converter for personal vaporizers. The output’s power of the controller can be adjusted to support the constant power’s output, which can automatically detect and match the atomizer’s resistance. Besides, The controller supports Ni/Ti material atomizer temperature’s control. This controller uses the full digital DC/DC converter with synchronous rectifier, which has a high power conversion efficiency to maximize the battery life. Category Monocell Representative Minimum value value 3.2V 3.7V 0.5A 5W 1V 1.5A - Maximal value Input voltage 4.3V Input currenton 35A Ooutput power 75W Output voltage 9V Output current 30A USB charging 4.8V 5V 6.5V voltage USB charging 400ma 450ma 500ma current Bouble cell Input voltage 6.4v 7.4v 8.6v Input currenton 0.5A 30A Output power 5W 120W Output voltage 1V 9V Output current 1.5A 1 30A Single, dual battery’s sharing parameters Atomizer 0.1R(0.05R 0.5R(0.15R 3.0R(1R TEMP) ‘sresistance TEMP) TEMP) Temperature Ni200/Ti control material Temperature 450F 200F(100C) 572F(300C) control Conversion 92% efficiency Quiescent 350UA 380UA 450UA dissipation 0.91 white / blue OLED Monitor Resolution This program needs to use 15C above discharge power battery Multiplying to supply electricity battery Operation and display : 1. For the first time, displaying the power logo for 3s, then turn to hibernation, now you need to switch ignition key 5 times within 2s continuously to go into the main interface. 2. Displaying main interface: Power mode : Temperature mode : 4.00V: Current battery . 0.00V/1.61V: Current output voltage 0.00R/0.08R: Current resistance value POWERFUL: Output mode storage channel 75W/40J: Output power or focus M1/M2: The current selection of the power value 00000.OJ: Total Output Joule energy temperature 572F: Stated temperature control 3. Lock mode : Press the ignition key 3 times continuously to enter the lock mode. Under the lock mode, the output of the controller is forbidden and can not be ignited. When press the button, the screen will show. Continuously press ignition key 3 times at this time, exiting the lock mode displaying then go into the main interface. 4. Adjusting the Power or Joule under the main interface: Click the Add button to enter the selected power / joule of the save channel, Once again, click the Add button to select the M1~M5 channel , After selecting the appropriate channel, then click the minus key to enter the current channel to adjust the power or Joule . Then click add, minus key to adjust the current power and Joule. After that, press the ignition key to exit this mode and save the corresponding value. 5. Select the output power mode under the main interface: In the main interface, click the button to enter the output power mode, Then click add, minus key to choose four kinds of output power: SOFT, STANDARD 、POWERFU+, POWERFUL. SOFT: The ratio of output power is 0.2 times lower than set power at the first 3 seconds, then output according to set power. STANDARD: Normal power’s output. POWERFU+: Output is 1.2 times of set power at the first 3 seconds, then output according to set power. POWERFUL:Output is 1.3 times of set power at the first 3 seconds, then output according to set power. Notice: The above situation must be in the case of the battery can be supported and not more than the maximum output power. 6. When there is a single battery charging, the interface is: 7. Entering into the set menu: In the main interface click the ignition key 5 times, then enter the setup menu. After which click the ignition key to switch the settings options. Plus, minus key is opening or closing the option . When the SENSOR is opened, the left and right button’s functions are the same with add, and minus keys. 7.1. Press plus, minus keys regulate power, Joule 7.2. Press plus, the keys to adjust the temperature 7.3. Press plus, minus keys to select the temperature unit 7.4. Press plus, minus keys to select the temperature control resistance wire material 7.5. Press plus, minus keys to return to the main interface 7.6. Press plus, minus keys to choose whether using the PASS BY mode output , Directly use battery voltage output in PASS BY mode 7.7. Press plus, minus keys to power off. 7.8. Press Plus, minus keys to choose whether enter into the USB upgrade mode. 7.9. Press plus, minus keys to select the left and right flip screen displaying mode. 7.10. Press plus, minus keys to select power or Joule mode. 7.11. Press plus, minus keys to choose whether openning the gravity sensor. 8. Protection and warning: 8.1. The controller has the function of battery back protection, when the battery positive and negative electrode reverse connection, the control panel automatically enters the protection without damaging any elements and the battery. 8.2. The controller can automatically detect and display the following kinds of alarms: “CHECK ATOMIZER” The controller doesn’t detect atomizer or atomizer circuit is broken. “CHECK BATTRY” Battery power can not afford the current output power. “TOO-HOT” Control board temperature is too high to shut itself down automatically. “TEMPERATURE PROTECT” Temperature protection under the mode of temperature control 9. Smoking timeout protection, when smoking more than 10S, automatically stop the output. 10. Screen displaying closed and controller turns into the sleep state when there is no press within 5 seconds. Any key will enable the controller to return to the normal display state under the sleep state.