* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Short-Circuit Generator Set for AICHI ELECTRIC CO., LTD.
Electric power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Stepper motor wikipedia , lookup
Power engineering wikipedia , lookup
Buck converter wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Electrical substation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Electrification wikipedia , lookup
Earthing system wikipedia , lookup
Power electronics wikipedia , lookup
Power inverter wikipedia , lookup
Alternating current wikipedia , lookup
Mains electricity wikipedia , lookup
Three-phase electric power wikipedia , lookup
[ Power Source Products for Special Applications ] Short-Circuit Generator Set for AICHI ELECTRIC CO., LTD. Keywords Short-circuit generator, Static excitation system, Medium-voltage inverter Abstract A short-circuit generator system is used to supply heavy currents and large power for the testing of circuit breakers, switchgears, insulators, and transformers by driving a generator with a motor. We recently received an order for a 330MVA (3Hz) short-circuit generator system for the High Power Laboratory of AICHI ELECTRIC CO., LTD., and supplied the system on full-turn-key contact. Major products we supply are a short-circuit generator system (motor and generator), reactors, medium-voltage inverters, control panels, monitoring systems, closing switches, circuit breakers, test sequencer, and measuring devices. 1 Preface We supplied a short-circuit generator system to AICHI ELECTRIC CO., LTD. Our scope of supply includes the main part of the short-circuit generator system and a control panel. Others include a closing switch, a test sequencer to control a closing switch and closing phase, and measuring devices for currents and voltages. This paper introduces the items mainly supplied. 2 Short-Circuit Generator 2.1 Motor-Generator Set The ratings of the short-circuit generator and the motor to drive this generator are as specified below. ( 1) Synchronous generator 330/275MVA (3Hz) – 60/50Hz – 2P – 3600/3000min−1 – 13200/11000V (Y)/7620/6350N (Δ) ( 2 ) Induction motor 1120/933kW – 6600/5500V – 60/50Hz – 2P – 3600/ 3000min−1 Fig. 1 shows an equipment layout drawing. For the generator, a 2-pole machine has been adopted because of its high revolving speed and large inertial energy. For the excitation system of the generator, a static excitation system with high responsiveness is adopted. Generator windings can be changed over between y-connection and Δ-connection with the 24 Noriyuki Koshizuka MEIDEN REVIEW Series No.167 2016 No.2 aid of an external disconnecting switch. For the y-connection at 60Hz, the rated voltage is 13,200V. At 50Hz, the rated voltage is 11,000V. For the Δconnection, the rated voltage is 7620V at 60Hz and 6350V at 50Hz, respectively. The system capacity is designed to carry a short-circuit current of more than 20kA for the Δ-connection at 60Hz. The adopted driving motor is a squirrel-cage rotor type induction motor. A medium-voltage inverter system is adopted for start-up operation and speed control. Bearings for the generator and the driving motor are of the plain sleeve bearing type. The lubricating system provides a lubricating oil from a forced lubricating oil supply unit at the time of start-up and stoppage. While the system is operated at the rated revolving speed, however, a pump directly connected with the motor-generator shaft feeds a lubricating oil to bearings for saving energy. 2.2 Control Unit Fig. 2 shows the switchgears and Fig. 3 shows the single-line connection diagram of this short-circuit generator system. ( 1) Medium-voltage inverter The medium-voltage inverter consists of three panels. The basic function is specified to control the speed at 3600min−1 at 60Hz and 3000min−1 at 50Hz. Its main feature is that the inrush current is small at the time of start-up. In addition, restarting is possible even in the middle of a stopping sequence. Stairs Waiting room Driving power supply Feeder panel 2 4765 Operation room Auxiliary panel DC supply unit Lubricating equipment Incoming feeder panel 1 Monitoring control desk Stairs Stairs Inverter panel Closing switch T R S VCB for R S protecT tion R S T Through bushing Soundproof room (Test bay) Short-circuit generator AVR panel 15,235 Generator room SCR panel Reactor R DS DS DS RL Phase R (Existing) RL Phase S (Existing) DS DS Electricity room DS DS DS Capacitors (Existing) DS DS・CH Circulating pump Fig. 1 RL Phase T (Existing) Cooler piping Stairs DS Reactor S DS CH Reactor T CH Disconnecting switch for y-Δ conversion DS Low-voltage high-current transformer (Existing) DS CH Exciting transformer Emergency genset 11,000 12,000 Unit: mm Equipment Layout Drawing Major products are neatly organized. In so doing, we factored the reduction of the overall footprint in the generator room. Fig. 2 Switchgears The switchgears are allocated in the line beside the short-circuit generator. ( 2 ) AVR panel The AVR control range is 0 to 110%. Using a touch panel mounted on the panel surface, the generator voltage can be regulated. Thyristors for rectifying field currents have enough capacity to carry 4000A in a short time. ( 3 ) Monitoring and operation panel Fig. 4 shows the control room where a touch panel is installed. Using this touch panel, various operations are possible at the monitoring and operation desk in this room, from the operation and stop of the auxiliary machines, to the run-stop of the main machine set and startup operation for short-circuit testing. Since indicator lamps and graphic panels are installed, it is possible to look over the full view of the testing system. MEIDEN REVIEW Series No.167 2016 No.2 25 26 MEIDEN REVIEW Series No.167 2016 No.2 IM CLR 64B 51F2 AS Single-Line Connection Diagram EXT Exciting transformer *A ZCT 2CT VCB 7.2kV A single-line connection diagram is shown. Fig. 3 Driving motor Wh Feeder panel 2 A/TC VS *A A 27B V/TD 67F2 AS 51R *A AS A CT M W2 CT U2 VT U1 R SG V1 S VT Current limiting reactors Current limiting reactors Current limiting reactors Current limiting reactors LA GCB 36kV LA LA GCB 36kV LA W1 VT Encoder Current limiting reactors T 3CT F1 F2 3VT T1 S1 Bus duct connections From exciting transformer A CT K50 V/TD N From inverter panel A From Incoming/Feeder panel 1 From inverter panel V From Incoming/Feeder panel 1 To measuring devices R4 S4 T4 Thyristor unit 51EX 51G VT K50 K60 59G VS Sh AVR V R R DV/TD DV/TD HV SCR panel F V AVR panel From SCR panel V F From SCR panel A T2 S2 R2 Low-voltage high-current transformer (Existing) Monitoring and operation desk R3 S3 T3 Short-circuit bars Short-circuit bars R1 Short-circuit bars Short-circuit bars Short-circuit bars To measuring devices Current limiting reactors LA VCB 15kV GCB 36kV LA 275/330MVA at 3-cycle-50/60Hz Voltage: 6.35/7.62kV (Δ connection) 11.0/13.2kV (Y connection) Synchronous generator CT V2 3PLBS Auxiliary panel Bus duct connections To HV SCR panel A V Vo Incoming/Feeder panel 1 67F1 51F1 A/TD TR VCB 7.2kV EVT 933/1120kW-5.5/6.6kW-50.5/60.6Hz-120A HCT Inverter panel Incoming transformer panel ZCT 2CT 2CT VCB 7.2kV 3φ-6.6kV-60Hz Fig. 4 Control Room Fig. 5 The control room is shown. Various operations can be carried out from here. Closing GCB An external view of reactors is shown. Signal converter unit BNC female VCB for protection BNC female BNC female From short-circuit generator To suppliers BNC female BNC cable BNC female BNC cable BNC female BNC cable Reactors BNC BNC female female BNC BNC male male 10:1 Probe BNC BNC male male 10:1 Probe BNC BNC male male 10:1 Probe BNC cable BNC BNC female female Sh Sh LC duplex optical fiber Receiver unit LC duplex optical fiber Receiver unit Transmitter unit BNC female BNC male LC duplex optical fiber Receiver unit BNC male BNC male Transmitter unit BNC female BNC male BNC male Transmitter unit BNC female Coaxial cable BNC male Transmitter unit Transmitter unit BNC male BNC male Transmitter unit Transmitter unit BNC BNC female female Sh Transmitter unit BNC male Transmitter unit Via touch panel Memory highcorder Rack top Electrical room Fig. 6 Test bay Operator console Monitoring and control room Measuring System Diagram A measuring system diagram is shown. Optical fiber cables are adopted for insulation. MEIDEN REVIEW Series No.167 2016 No.2 27 ( 4 ) Others In the event of a power outage for this testing system, the interruption of lubricant supply to bearings is a big concern. As such, an emergency generating system is used as a backup power for the auxiliary power supply. At the same time, a DC pump is installed. In this manner, this makes a redundant lubrication oil supply system which is intended to improve reliability. 3 Reactors Fig. 5 shows a view of reactors. Two reactor sets with different capacities are allocated to each phase. Reactor 1 is served by seven combinations of changeover switches, and four combinations of changeover switches for Reactor 2. Twenty eight (28) combinations of current adjustment are, therefore, possible. 4 Closing Switch In short-circuit testing, a closing-phase control function is required. The supplied test sequencer assures a high performance of adjustments to a testing condition of 1/10000s (0.1ms). Signals from the test sequencer are controlled through high-speed conversion performed by the Insulated Gate Bipolar Transistor (IGBT) switches. For the closing switch, a 36kV gas-insulated circuit breaker is adopted, which assures a closing accuracy of ±0.5ms. 5 Measuring Devices Fig. 6 shows the measuring system diagram. The current transformers that measure short-circuit currents are installed in the test bay. These are special products rated 30,000/15A. They use the BNC connections where a 1Ω resistor generates a 15V voltage. Optical fiber cables are used between the test ( bay where equipment under test is placed) and the monitoring and control room (where the measuring devices are installed). This is an excellent measured data transmission method because the optical fiber cable can insulate the surge voltages caused by the switching of short-circuit currents or high voltages. 6 Postscript A short-circuit generator system is an important facility for the performance verification of circuit breakers and switchgears. Customers who have short-circuit generator systems are limited in number and regular orders cannot be expected. We consider, however, our mission is to keep improving technology for our customers. Lastly, we would like to express our gratitude to all project-related personnel for their helpful suggestions and guidance for the production and supply of this system. ・All product and company names mentioned in this paper are the trademarks and/or service marks of their respective owners. 28 MEIDEN REVIEW Series No.167 2016 No.2