Download Transformer Turn Ratio IRT-101

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Immunity-aware programming wikipedia , lookup

Audio power wikipedia , lookup

Power over Ethernet wikipedia , lookup

Mercury-arc valve wikipedia , lookup

Islanding wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Electric power system wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Ground (electricity) wikipedia , lookup

Stray voltage wikipedia , lookup

Power inverter wikipedia , lookup

Electrification wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Power electronics wikipedia , lookup

Multimeter wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Buck converter wikipedia , lookup

Voltage optimisation wikipedia , lookup

Rectifier wikipedia , lookup

Decibel wikipedia , lookup

Single-wire earth return wikipedia , lookup

Electrical substation wikipedia , lookup

Power engineering wikipedia , lookup

Distribution management system wikipedia , lookup

Opto-isolator wikipedia , lookup

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Mains electricity wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transformer wikipedia , lookup

Transcript
CRIEM GROUP
Electroelectronics Products and Sevices – Cases Representative – Multi–Contact Distribuitor
Transformer Turn Ratio IRT-101
General Overview
The Transformer Turn Ratio Meter IRT-101 is an instrument designed to
accurately measure to the transformer turn ratio providing an easy reading on the
panel. It can be used both in the field and laboratory, powered by 127VCA or 220VCA,
to test power and distribution single-phase transformers such as other transformers
designed to work from 25 to 60 Hz.
The low-side of the transformer under test must be rated to voltages higher or equal
to 6Vrms. When operating in 6Vrms the excitation current is around 1.5Arms. Then
almost all power and distribution transformers can be tested by IRT-101.
It allows to detect windings in short-circuit or open-circuit.
Technical Specifications
Transformer Turn Ratio IRT-101
Power Supply
Ranges of measurement
127or 220VCA ± 5% 50/60Hz
From 0,0001 to 119,9999
CRIEM CRIAÇÕES ELETROMECÂNICAS LTDA – CRIEM IMPORTS LTDA
28 Crepúsculo Street, Califórnia – Zip Code: 30855-435 – Belo Horizonte / Brazil – Phone:+55 31 3389-4159
Fax +55 31 3389-4158
www.criem.net / [email protected]
CRIEM GROUP
Electroelectronics Products and Sevices – Cases Representative – Multi–Contact Distribuitor
Accuracy
±0.1% of the reading ± 0.001
Input Voltage of Measurement From 0 to 10VAC
Input Current of Measurement From 0 to 2.0Aac
Sampling Time
25ms
Output Voltage
From 0 to 10VAC
Output Current
From 0 to 2.0Aac (limited by the load)
Relative Humidity
From 10 to 85%
Temperature of Operation
From 5 to 30°C
Storage Temperature
From 0 to 45°C
Weight
10kg
Dimensions
38 x 31 x 18 cm
Included accessories
Power cord in Brazilian Standard 1.5 meters long; 2 units of double measuring leads 4
meters long; 2 units of leads with Kelvin Clips (color-coded), 4 meters long; User
Manual in English; Calibration Report; Metallic, robust box to transport the equipment.
CRIEM CRIAÇÕES ELETROMECÂNICAS LTDA – CRIEM IMPORTS LTDA
28 Crepúsculo Street, Califórnia – Zip Code: 30855-435 – Belo Horizonte / Brazil – Phone:+55 31 3389-4159
Fax +55 31 3389-4158
www.criem.net / [email protected]