* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Mark the ( ) and ( ) answer:
Ground (electricity) wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Stepper motor wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrical substation wikipedia , lookup
Electrical ballast wikipedia , lookup
Two-port network wikipedia , lookup
Current source wikipedia , lookup
Power MOSFET wikipedia , lookup
Power electronics wikipedia , lookup
Integrating ADC wikipedia , lookup
Distribution management system wikipedia , lookup
Alternating current wikipedia , lookup
Surge protector wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage regulator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Schmitt trigger wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Opto-isolator wikipedia , lookup
Mark the ( ) and ( ) answer: Q1) Refer to VOM AC voltage measurement: 1. AC voltage is applied to input jacks A1J2 and A1J3. 2. On low range scales (.015 Vac and 1.5 Vac), the input voltage is applied directly to buffer A3U1. 3. Operational amplifier (buffer circuit) A3U1 prevents the divider network A3R13 ~ A3R22 from loading the input signal. 4. A3R49 and A3R50 are series dropping resistors which supply the meter with the proper voltage for full scale deflection. 5. A1RT1 is a thermistor which compensates for changes in ambient temperature to maintain a relatively constant meter response. 6. Protection diodes A1CR1 and A1CR2 limit the voltage across the meter. Q2) Refer to DC voltage measurement: (higher/ divider network / input / AC / dropping / F.S.D.) 1. A3U1 prevents the divider network from loading the ………. signal. 2. A3S2A determines whether the input voltage is applied directly or to ………………... 3. Resistors A3R21 and A3R22 used at ……… operation. 4. A3R34 and A3R35 are dropper resistors, produce ……………. 5. A3R25 is a dropping ……………….resistor. 6. At ………… ranges the input voltage is divided by a divider network before applying to A3U1. Q3) Refer to AC current measurement: (A1S1 / A3U2A / A3R58 / Vac / Aac) 1. ………….. selects the resistor in the divider. 2. ………….. amplifies the divider voltage by a factor of 1.6. 3. …………. is adjusted for a zero output on meter A1M1 with output of A3U3 shorted. 4. …………. is adjusted when switch A3S1 is set to the …………. function and should not be adjusted in the ………… mode. Q3) Refer to OHMS measurement: -Ve +Ve 1) A3VR3 is ………. Voltage regulation Circuit 2. A2VR1 ………. Voltage regulation Circuit 3. A2VR1 output is applied to the divider network (A3R69 ~ A3R75) 4. A3R69 ~ A3R75, A2R1, and the unknown resistance create a voltage divider with a voltage drop proportional to the unknown resistance. 5. A1R1 cancels any offset voltage that cause an untrue reading. 6. A3U2A establishes a voltage across resistors A3R37 and A1RT1 to produce full scale deflection. 7. At LPΩ, A3R79 is replaced by A3R80 and A3R81 LPΩ ADJ. 8. At LPΩ, A3R37 replaced by A3R36, determines the voltage applied to A1M1. 1) Ohms scales are relatively linear.