Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
STEP PROJECT BOVEC EXERCISE FORM 1) BUILDING IDENTIFICATION Municipality BOVEC Province: ________________________________ Country: SLOVENIA Locality CESOZCA Name of building/owner: _________________________________________________________ Building number |__|__| Address: ______________________________________________________________________ Number |__|__|__|__|__| PC |__|__|__|__|__| Cadastral Data: |__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__|__| GIS Coordinates X: |__|__|__|__|__|__|__|__|__|__|__|__|__|__| Ownership : private Y: |__|__|__|__|__|__|__|__|__|__|__|__|__|__| Type: |__|__|__| public 2) BUILDING GEOMETRY AND USE Total number of storeys |__|__| Number of underground storeys |__|__| Average interstorey high (m) |__|__|,|__| Position: isolated inner Year of construction/ intervention Unknown Basement yes no Average floor area (sm) |__|__|__|__|__| border corner Type of intervention Unknown Use Residential Units for that use |__|__| Number of people at the moment of Strategic (Hospital, OSOCC) |__|__| the event |__|__|__|__| ≤1900 Repair 1901-1940 Upgrade Relevant (Schools, ..) |__|__| 1941-1960 Retrofit Commercial |__|__| 1961-1981 Floor addition Offices |__|__| 1981-2001 Other Touristic |__|__| Not used |__|__| Other |__|__| ≥ 2001 3) BUILDING TYPE Prevailing vertical bearing structure Prevailing horizontal structure Unknown Unknown Wooden building Vaults RC building Unknown Flexible floors (wooden) MRF shear walls Dual system Semi-rigid floors (steel beams and clay tiles) Steel building Unknown Rigid floors (RC) MRF braced RC walls Roof Masonry or Mixed (masonry & RC, masonry & Wood) building Unknown Unknown irregular layout or bad quality masonry (round stones, pebbles, HCT..) regular layout and good quality masonry (square stones, full bricks,..) Retrofitted (injections, FRP, RC walls, etc.): Mixed building: not applicable Unknown Unknown in plan Prefabricated. Other _____________________________________________ Yes No in vertical Unknown Thrusting Light Non thrusting Heavy Ties and Beam ties (masonry or mixed buildings) Absent Few Many Stair position Unknown Symmetric resp. 2 axes Vulnerabilities for RC/Steel buildings (multi-option) Dissymmetric Symmetric resp. 1 axe Vulnerabilities for Masonry/Mixed buildings (multi-option)i Soft storey (pylotis) Poor quality mortar short columns Thrusting structures without ties or ring beams Frame in one direction only Walls not connected Infill walls out of the structural frame Large openings / close to the corners / non in vertical Irregularity in plan Chimney in walls Irregularity in elevation (excluding soft storey) Irregularity in plan Absence of seismic joints Irregularity in elevation 4) DAMAGE Structural damage Non structural damage D0 D1 D2 D3 D4 Damage to partitions D5 Vertical structures Falling of chimney, tiles Damage to water / sewage plant Damage to electric/gas plant Falling of plaster Floors Falling of false ceiling Stairs Falling of parapets,.. .................... .................... Roof Infill walls Overall damage External risk On the building On the building entrance On the building lateral roads Risk of objects falling from adjacent buildings Risk of objects falling from adjacent soil Damage to lifelines (water, sewage, gas, ..) Soil and foundation Soil morphology Valley Flat Slope instability Mild slope Damage to soil Steep slope Crest or Top Damage to foundation 6) CASUALTIES injured |__|__|__|__| victims |__|__|__|__| evacuated people |__|__|__|__| evacuated families |__|__|__|__| Restricted use (yellow) Unusable (red) 7) SAFETY ASSESSMENT Building usability Usable (green) Immediate risk of collapse no no Access to the building Yes Partially, temporarily or with other restriction Access to the Area No Yes To retrieve goods Yes No No Type of restrictions__________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________ 8) SHORT TERM COUNTERMEASURES None Location and description………………….. Location and description…………………….….. Removal of falling objects Small repairs Shoring Tightening Propping Other 9) ACCURACY OF THE INSPECTION From outside only Inspection not performed because of Partial Refused Ruins Other reasons Complete No owner found Demolished _____________________________ NOTES: ____________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________ __________________________________________________________________________________________________________________________ Date: ___/___/___ Name and sign __________________________ Inspectors: Team number |__|__|__|__| Name and sign __________________________ Name and sign ____________________